Chapter 2 Installation
Chapter 2. Installation
2.1 Introduction
The Installation chapter will cover the physical installation of the IPM-4SE, 4-Port E1 IP Multiplexer, the
electrical connections, interface connections and cabling requirements. A brief overview of the functional
components such as main unit and management options will also be outlined in this chapter.
Required Tools
You will need these tools to install the IPM-4SE:
Number 2 Phillips screwdriver for the 3mm and the 12-24 rack installation screws.
Wrist strap or other personal grounding device to prevent ESD occurrences.
Antistatic mat or antistatic foam to set the equipment on.
2.2 Unpacking
If there is a possibility for future relocation of the IPM-4SE unit, please keep the packing cartons and
protection packaging materials. Carefully unpack and inspect the unit and accessories for potentially
damaged or missing parts. Contact our nearest sales representative or our company directly if you detect any
damaged or missing parts. Improper handling during shipment may cause early failure. Notify the shipper or
forwarder immediately if the outer package shows signs of dropping or rough handling.
2.3 Site Preparation
Install the IPM-4SE within reach of an easily accessible grounded AC outlet or three wire (-48VDC, Power
return, Earth Ground) central office power. The AC outlet should be capable of furnishing 90 to 250 VAC.
Refer to 2.4 Electrical Installation. Allow at least 10cm (4 inch) clearance at the front of the IPM-4SE for the
E1 and LAN copper cables.
2.4 Mechanical Assembly
The IPM-4SE is designed for desktop, shelf or rack mount installation and will require 1U space in a
standard EIA 19" rack. The IPM-4SE chassis is delivered completely assembled upon delivery. The rack
mount adapters may be placed along the front of the chassis as shown below.
Figure 2.1 Standard 19" Rack-Mount Installation of IPM-4SE Unit requires 1RU space
10