CTC Union FRM220-TM-10GMUX Скачать руководство пользователя страница 2

 

LEGAL 

The information in this publication has been carefully checked and is believed to be entirely accurate at 
the time of publication. CTC Union Technologies assumes no responsibility, however, for possible errors 
or omissions, or for any consequences resulting from the use of the information contained herein. CTC 
Union Technologies reserves the right to make changes in its products or product specifications with the 
intent to improve function or design at any time and without notice and is not required to update this 
documentation to reflect such changes. 
 
CTC Union Technologies makes no warranty, representation, or guarantee regarding the suitability of its 
products  for  any  particular  purpose,  nor  does  CTC  Union  assume  any  liability  arising  out  of  the 
application  or  use  of  any  product  and  specifically  disclaims  any  and  all  liability,  including  without 
limitation any consequential or incidental damages. 
 
CTC  Union  products  are  not  designed,  intended,  or  authorized  for  use  in  systems  or  applications 
intended to support or sustain life, or for any other application in which the failure of the product could 
create a  situation where personal  injury or death may occur. Should the Buyer purchase or use a  CTC 
Union product for any such unintended or unauthorized application, the Buyer shall indemnify and hold 
CTC  Union  Technologies  and  its  officers,  employees,  subsidiaries,  affiliates,  and  distributors  harmless 
against all claims, costs, damages, expenses, and reasonable attorney fees arising out of, either directly 
or  indirectly,  any  claim  of  personal  injury  or  death  that  may  be  associated  with  such  unintended  or 
unauthorized use, even if such claim alleges that CTC Union Technologies was negligent regarding the 
design or manufacture of said product. 

 

WARNING: 

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment 
generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with 
the instruction manual may cause harmful interference in which case the user will be required to correct 
the  interference  at  his  own  expense.  NOTICE:  (1)  The  changes  or  modifications  not  expressively 
approved  by  the  party  responsible  for  compliance  could  void  the  user's  authority  to  operate  the 
equipment.  (2)  Shielded  interface  cables  and  AC  power  cord,  if  any,  must  be  used  in  order  to  comply 
with the emission limits. 
 
This is a Class A product. In a domestic environment this product may cause radio interference in which 
case the user may be required to take adequate measures. 

Содержание FRM220-TM-10GMUX

Страница 1: ...1 User Guide sales ctcu com FRM220 TM 10GMUX 7 x 1GE to 10G Muxponder ...

Страница 2: ...d application the Buyer shall indemnify and hold CTC Union Technologies and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages expenses and reasonable attorney fees arising out of either directly or indirectly any claim of personal injury or death that may be associated with such unintended or unauthorized use even if such claim alleges that C...

Страница 3: ...their respective owners Technical information in this document is subject to change without notice CTC Union Technologies Co Ltd Far Eastern Vienna Technology Center Neihu Technology Park 8F No 60 Zhouzi St Neihu Taipei 114 Taiwan T 886 2 26591021 F 886 2 26590237 E sales ctcu com H www ctcu com ...

Страница 4: ...aser Shutdown 11 Client Side Loopback Test LBT Function 11 Link Fault Pass Through LFP 12 LINE TO CLIENT LFP APPLICATION 12 CLIENT TO CLIENT LFP APPLICATION 13 Console Management 15 CONSOLE TERMINAL SETTINGS 15 L LINE CONFIGURATION AND INFORMATION 16 1 7 CH1 CH7 CONFIGURATION AND INFORMATION 17 A ALARM CONFIGURATION AND INFORMATION 18 D DEVICE CONFIGURATION AND INFORMATION 19 S STORE PARAMETERS 19...

Страница 5: ...20 TM 10GMux can be installed in a 19 inch 2U 20 slot chassis FRM220 CH20 or 19 inch 1U 8 slot chassis FRM220 CH08 Both housings can be monitored and configured through SNMP Web GUI or Telnet using a NMC management module By using FRM220 TM 10GMux in the network it provides significant cost reduction and excellent fiber utilization when it is compared with CWDM optical multiplexing Features 7 x 1G...

Страница 6: ...s on the client side support loopback test LBT function Support CV error counter on a per port basis Support Auto Laser Shutdown ALS function Support in band remote management Support SFP SFP DDMI Service Type Client Side 7 CH1 CH7 x 1000Base x Interface 1 25G SFP slot Service Type Line Side 1 x 10Gbps proprietary frame format Interface 10G SFP slot Environment Temperature 0 55 C Humidity 10 90 Di...

Страница 7: ...GMux is placed in a stand alone chassis such as FRM220 CH02M with serial management port these devices also support a text based serial terminal with an easy to use menu system for configuration When placed in a managed chassis such as FRM220 CH20 and FRM220 CH08 the card is configured and monitored through the chassis NMC network management controller via console Telnet Web HTTP or SNMP 1 2 3 4 ...

Страница 8: ... into the chassis and secure the thumb screw No tools are required however if a card s screw is over tightened it may require loosening with a small flat blade screwdriver Please refer to the figure below Figure 1 Muxponder Card being Inserted into 20 Slot Chassis Chassis Installation II The double width blade card can be inserted into two slot chassis for a completely assembled standalone unit Wh...

Страница 9: ...d by CTC Union are of the Bale Clasp type The bale clasp pluggable module has a bale clasp that secures the module into the SFP or SFP cage Inserting a Bale Clasp SFP SFP Module into the cage Step 1 Close the bale clasp upward before inserting the pluggable module Step 2 Line up the SFP SFP module with the port and slide it into the cage Removing a Bale Clasp SFP SFP Module Step 1 Open the bale cl...

Страница 10: ... is initialing Firmware Upgrading System abnormal FPGA cannot boot up normally ALM Amber On Alarm Off Normal LFPT Amber On LFP function Line or Client is enabled Off LFP function is disabled LINE Green On Link is up SYNC Off Link is down Blinking ON OFF 1 sec for Sync Loss ON OFF 0 5 sec for Loopback CH1 CH7 Green On Link is up SYNC Off Link is down Blinking ON OFF 1 sec for Sync Loss ON OFF 0 5 s...

Страница 11: ...20 TM 10GMux is useful for debugging a dysfunctional SFP link CH1 CH7 In loopback mode the signal is routed into the Cross Switch circuitry and then routed back to the signal source Loopback may be enabled via management terminal console When placed in a managed FRM220 CH20 or CH08 chassis the loopback test function can also be controlled by the NMC manager in FRM220 chassis In the example below w...

Страница 12: ...link fault through the device to the SFP at the Client side when SFP LFP function at the Line side enabled Therefore if a link fails on the SFP Line side the Muxponder will force the SFP CH1 CH7 at the Client side link down For example As shown in the figure above if a fault occurs on the 10G SFP Line side with local Line LFP enabled the Muxponder would force each channel in the local Client side ...

Страница 13: ...agram shows that LFP function of CH1 in local client side is enabled but the remote client side is disabled When the link fault occurs at the local side this will force the remote client link down On the other hand when the link fault occurs at the remote side this will not force the local client link down CH1 LFP disabled Local Client SFP CH 1 1G SFP CH 7 FRM220 TM 10GMux 10G SFP LINE FRM220 TM 1...

Страница 14: ...d LFP enabled Local Remote client link down Remote Local client link down LFP enabled LFP disabled Local Remote client link down Remote Local client link up LFP disabled LFP enabled Local Remote client link up Remote Local client link down LFP disabled LFP disabled Local Remote client link up Remote Remote client link up ...

Страница 15: ...te 115 200 Data bits 8 Parity bits none Stop bits 1 Handshaking none Emulation VT 100 Default Username admin Default Password None Just press Enter key Connect the serial cable to the CH02M s DB9 Run the terminal emulation program With power on press ESC or Enter to display the Main Menu screen The following is an example CTC UNION TECHNOLOGIES CO LTD FRM220 TM 10GMux Manager Alarm Local Ver 1 000...

Страница 16: ... of Line channel You can also activate or deactivate the Line channel enable or disable LFP or ALS function and reset CV counters DDM The modern optical SFP transceivers support digital diagnostics monitoring DDM functions according to the industry standard SFF 8472 This feature is also known as digital optical monitoring DOM and gives the end user the ability to monitor real time parameters of th...

Страница 17: ...t and reset CV counters CTC UNION TECHNOLOGIES CO LTD FRM220 TM 10GMux Manager Alarm Local Ver 1 000 1 001 0 000 0 001 CH02M S2 CH 3 Configuration And Information SFP Exist DDM Yes TxFault No Link Down Sync No Vendor Name CTC UNION TX Power 41 dBm Vendor Number SFS 7050 Z55 DD RX Power 41 dBm Vendor SN FC1608032025 RX Sensitivity 24 dBm Fiber Type Single Temperature 036 C TX Wave Length 1550 nm Su...

Страница 18: ...arm in Alarm Status Otherwise Normal will be shown in Alarm Status When alarms occur the Alarm LED indicator on the front panel will also be lit in amber CTC UNION TECHNOLOGIES CO LTD FRM220 TM 10GMux Manager Alarm Local Ver 1 000 1 001 0 000 0 001 CH02M S2 Alarm Configuration And Information Alarm Status Alarm Alarm Triggers L Line 1 CH1 2 CH2 3 CH3 4 CH4 5 CH5 6 CH6 7 CH7 ESC Go to previous menu...

Страница 19: ... S Store Parameters Press S key and then Y to save the setting parameters into non volatile RAM NVR CTC UNION TECHNOLOGIES CO LTD FRM220 TM 10GMux Manager Alarm Local Ver 1 000 1 001 0 000 0 001 CH02M S2 Device Configuration And Information SN System Status OK 1 Device Active Enable 2 Device Reset 3 Device Set To Default ESC Go to previous menu Please select an item ...

Страница 20: ...ebook computer that has an RS232 port or via a commonly available USB to RS232 adapter Then use a serial terminal that can support XMODEM such as TeraTerm to start Firmware upgrade process Quick Procedure 1 In the Main Menu Key in U to enter Firmware upgrade page Then Key in 1 to start uploading Firmware 2 Send Firmware file via Xmodem and select the Firmware file that you want to upload ...

Страница 21: ...e local card has been upgraded to the newest firmware then you can use console terminal to upgrade firmware of the remote card P Password change Enter this menu to change the login password The old password must be keyed in followed by the new password twice If the password is ever forgotten please contact customer support for details on resetting the password CTC UNI ON TECHNOLOGI ES CO LTD FRM 2...

Страница 22: ...m Configuration Setup Then U Upgrade Line Card Menu CTC UNION TECHNOLOGIES CO LTD FRM220 NMC VER 3 45 Upgrade Line Card Menu Target IP 59 125 162 252 Target Gateway 59 125 162 241 TFTP Server IP 59 125 162 243 Please select a card type Next Page Press Z or z 1 FRM220 10 100i and FMC 10 100i 3 FRM220 Serial 2 FRM220 FXO FXS 4 FRM220 155MS 5 FRM220 Data 6 FRM220 E1 T1 7 FRM220 1000EDS 1000ES 2F 8 FR...

Страница 23: ...rade firmware of the remote card via the local card by clicking the Upgrade Remote Side F W function key The remote upgrade will take approximately 35 minutes to complete Please select a card type Next Page Press Z or z 1 FRM220 1000DS 2 FRM220 OPS51 OPS52 3 FRM220 DS3 E3 4 FRM220 DS3 E3 FPGA 5 FRM220A iMux4T 6 FRM220A iMux4S 7 FRM220 FXO FXS 4 8 FRM220 FXO FXS 4 FPGA 9 FRM220 GFOM04 08 A FRM220 1...

Страница 24: ...24 Version Date Description 1 0 2020 03 16 Preliminary version ...

Отзывы: