CTC Union FRM220-CH08 Скачать руководство пользователя страница 9

Chapter 1  Introduction 

 

1.6 Chassis Specifications 

Environment 

Temperature 

-10 - 50

C Ambient (14-122

F) 

Humidity  

5-95% non condensing 

 

Alarm relay contact ratings 

125VAC 

1A 

110VDC 

0.6A 

30VDC 

4A 

 

Power Module Specifications 

AC Power Module 
 

Input : Universal, 100 ~ 240 ±10% VAC; Frequency : 50/60 Hz ±10% 

 

Output : DC 12V, 180W maximum rating 

 

Connector : C14 (IEC 60320-1) 

DC Power Module 
 

Input :   36 ~ 60 VDC (DC48) 

 

Output : DC 12V, 200W (DC48) maximum rating 

 

Connector : 3 connector terminal block 

 

AC Power Cord Specification

 (detachable cord, C13 connector, with national plug per national standards)

 

 

6A rated 18AWG (conductors with a minimum cross-section area of 0.75 mm

2

DC Power Cord Specification

 (wiring must comply with EN 60950-1:2006 standard)

 

 

Conductors with a minimum cross-section area of 1mm

2

 (16AWG) 

Protective Earth (PE) Specification

 (wiring must comply with EN 60950-1:2006 standard)

 

 

Conductor with a minimum cross-section area of 0.75mm

2

 (18AWG), star washer and non-self-tapping M3.5 screw 

Power Consumption 

 

~60 watts (fully loaded chassis, with random mix of line card types) 

Heat Generation 

 

~120 BTU (fully loaded chassis, with random mix of line card types) 

Compliance 

 

European Union : EN55022:2006, Class A, EN55024:1998+A1:2001+A2:2003, and EN60950-1:2001 

 

FCC : part 15, subpart B, class A 

Reliability 

 

MTTB : >65,000 hours (25

C) 

Physical Specifications 

 

Dimensions : 438mm (Width) x 302mm (Depth) x 44mm (Height) 

 

 

(US: 17 1/4" wide x 11 7/8" deep x 1 3/4" high) 

 

Weight : 2.6Kg (US: ~5.75 lbs) 

 
 

AC module weight : 1050g (US 2.3 lbs) 

 

DC module weight : 930g (US 2 lbs) 

 

NMC card weight : 120g (US 0.25 lbs) 

 
 

Net Weight : 4.6kgs (US 10 lbs) 

 

(with 1 NMC, 1 AC +1 DC power module & two bracket panels for 19" rack-mounting) 

 
 

Fully Populated Reference Net Weight: 5.5Kg (US 12 lbs.) 

 

(fully loaded, two powers, NMC and 7 pcs 10/100i line cards) 

 

1.7 NMC (SNMP) 

The 

FRM220-CH08

  must  be  ordered  with  an  NMC  Card.  The  card  is  placed  in  the  far  left,  upper  card  slot. 

Management is accomplished either  via  local control on the  asynchronous RS-232 port  with an ASCII terminal or 
via  Ethernet  and  any  standard  SNMP  network  management  software  that  supports  MIB-II.  The  WEB  GUI  based 
interface  provides  an  easy  method  for  the  user  to  operate  and  monitor  the  whole  system.  Almost  all  line  cards 
support remote in-band configuration when paired with the same type stand-alone in-band converter. 

 

1.8 Line card options 

The 

FRM220

 is capable of supporting a variety  of in-band managed or non-in-band managed  line card types 

which may be mixed and matched in any slot of the rack. See below for a brief of the line cards at the time of this 
printing. Please refer to the latest version of 

FRM220  NMC  User  Manual

 for details of all the line card options for 

the 

FRM220

Содержание FRM220-CH08

Страница 1: ...FRM220 CH08 Hardware Installation...

Страница 2: ......

Страница 3: ...x 886 2 27991355 Email sales ctcu com URL https www ctcu com FRM220 CH08 Hardware Installation Manual Fiber In band Managed Media Platform Rack 8 Slot 1U Version 1 0 February 7 2012 official release V...

Страница 4: ...injury or death that may be associated with such unintended or unauthorized use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product...

Страница 5: ...3 Mechanical Assembly 10 2 3 1 Rack mounting 10 2 3 2 Power Fan Modules Removal Replacement 11 2 3 3 Line Card Conversion Stand alone Rack 11 2 4 Electrical Installation 12 2 5 Alarm Installation 12...

Страница 6: ...Table of Contents ii...

Страница 7: ...dular Media Chassis provides an economic solution for high density Fiber Converter installations in enterprises or central offices All critical components Power fans management module and interface ca...

Страница 8: ...1 ON relay 1 is closed ALM 2 Red When On NMC has set Alarm 2 ON relay 2 is closed Figure 1 2 Relays and LEDs 1 4 Chassis Rear Description The rear panel holds the hot swappable power fan modules The...

Страница 9: ...CC part 15 subpart B class A Reliability MTTB 65 000 hours 25 C Physical Specifications Dimensions 438mm Width x 302mm Depth x 44mm Height US 17 1 4 wide x 11 7 8 deep x 1 3 4 high Weight 2 6Kg US 5 7...

Страница 10: ...t on 2 2 Site Preparation Install the FRM220 CH08 within reach of an easily accessible grounded AC outlet or three wire 48VDC Power return Earth Ground central office power The AC outlet should be cap...

Страница 11: ...the 2 7G and 10G the chassis will require two power fan modules or overheating could result Figure 2 2 Power Modules for CH08 2 3 3 Line Card Conversion Stand alone Rack The FRM220 Media Converter Li...

Страница 12: ...the power cable in AC installations or via the frame ground connection for DC installations Figure 2 4 IEC AC terminal block DC power connector pin assignment 2 5 Alarm Installation The alarm relay p...

Страница 13: ...ings slot number 1 may then be used for a non managed media converter line card 2 7 Line Card Installation The Line Cards for the FRM220 Series are Fiber Media Converter Cards which slide into CH08 ch...

Страница 14: ...inal Equipment of PC s COM port The FRM220 includes the 1 1 DB9F to DB9M serial cable for connection to PC s COM port or laptop s USB to RS 232 adapter Any VT100 terminal emulation program for Windows...

Страница 15: ...upgrade line cards in the FRM220 Setup the default gateway subnet mask and IP address as instructed by your network administrator After any TCP IP setting change the NMC must be rebooted So ESC back...

Страница 16: ...ement IP address The following is an example of a Telnet screen It is the same as a local serial console screen only it can be accessed remotely 3 5 Web Based Manager The FRM220 NMC supports web based...

Страница 17: ...d by CTC Union It is a client server architecture using a Windows based server with Microsoft MS SQL Server for a database and Java based server and client The client software can be run on the server...

Страница 18: ...Chapter 3 Management Quick Start 18...

Страница 19: ......

Страница 20: ......

Отзывы: