![CTC Union FRM220-CH08 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/ctc-union/frm220-ch08/frm220-ch08_hardware-installation_2693261009.webp)
Chapter 1 Introduction
9
1.6 Chassis Specifications
Environment
Temperature
-10 - 50
C Ambient (14-122
F)
Humidity
5-95% non condensing
Alarm relay contact ratings
125VAC
1A
110VDC
0.6A
30VDC
4A
Power Module Specifications
AC Power Module
Input : Universal, 100 ~ 240 ±10% VAC; Frequency : 50/60 Hz ±10%
Output : DC 12V, 180W maximum rating
Connector : C14 (IEC 60320-1)
DC Power Module
Input : 36 ~ 60 VDC (DC48)
Output : DC 12V, 200W (DC48) maximum rating
Connector : 3 connector terminal block
AC Power Cord Specification
(detachable cord, C13 connector, with national plug per national standards)
6A rated 18AWG (conductors with a minimum cross-section area of 0.75 mm
2
)
DC Power Cord Specification
(wiring must comply with EN 60950-1:2006 standard)
Conductors with a minimum cross-section area of 1mm
2
(16AWG)
Protective Earth (PE) Specification
(wiring must comply with EN 60950-1:2006 standard)
Conductor with a minimum cross-section area of 0.75mm
2
(18AWG), star washer and non-self-tapping M3.5 screw
Power Consumption
~60 watts (fully loaded chassis, with random mix of line card types)
Heat Generation
~120 BTU (fully loaded chassis, with random mix of line card types)
Compliance
European Union : EN55022:2006, Class A, EN55024:1998+A1:2001+A2:2003, and EN60950-1:2001
FCC : part 15, subpart B, class A
Reliability
MTTB : >65,000 hours (25
C)
Physical Specifications
Dimensions : 438mm (Width) x 302mm (Depth) x 44mm (Height)
(US: 17 1/4" wide x 11 7/8" deep x 1 3/4" high)
Weight : 2.6Kg (US: ~5.75 lbs)
AC module weight : 1050g (US 2.3 lbs)
DC module weight : 930g (US 2 lbs)
NMC card weight : 120g (US 0.25 lbs)
Net Weight : 4.6kgs (US 10 lbs)
(with 1 NMC, 1 AC +1 DC power module & two bracket panels for 19" rack-mounting)
Fully Populated Reference Net Weight: 5.5Kg (US 12 lbs.)
(fully loaded, two powers, NMC and 7 pcs 10/100i line cards)
1.7 NMC (SNMP)
The
FRM220-CH08
must be ordered with an NMC Card. The card is placed in the far left, upper card slot.
Management is accomplished either via local control on the asynchronous RS-232 port with an ASCII terminal or
via Ethernet and any standard SNMP network management software that supports MIB-II. The WEB GUI based
interface provides an easy method for the user to operate and monitor the whole system. Almost all line cards
support remote in-band configuration when paired with the same type stand-alone in-band converter.
1.8 Line card options
The
FRM220
is capable of supporting a variety of in-band managed or non-in-band managed line card types
which may be mixed and matched in any slot of the rack. See below for a brief of the line cards at the time of this
printing. Please refer to the latest version of
FRM220 NMC User Manual
for details of all the line card options for
the
FRM220
.
Содержание FRM220-CH08
Страница 1: ...FRM220 CH08 Hardware Installation...
Страница 2: ......
Страница 6: ...Table of Contents ii...
Страница 18: ...Chapter 3 Management Quick Start 18...
Страница 19: ......
Страница 20: ......