Chapter 3. Operation
31
3.4.7 Device Configuration Menu
The menu screen is broken into two parts, the informational part and the setting part.
Information shown includes the current time, Uptime of the device, power types (AC or DC) and power status.
<1> Device Active
Indicates if the device is enabled or disabled. When disabled, no traffic will flow through the
device. A confirmation will be required to disable the device.
<2> Device Reset
When performing a device reset the CPU will reboot, FPGA code is reloaded and the saved
configuration is restored. During the reset, no traffic will flow through the device. A confirmation will be required prior
to resetting.
<3> Manager Default
All management settings, IP address, SNMP community strings will all be returned to factory
default.
<4> System Default
When performing a system default, all configuration settings of tributaries, optical and LAN will
be reverted to the factory default settings. Doing a system default on an in service device could lead to traffic
disruption. Therefore, a confirmation will be required before the system default is performed.
Device Reset
and
System Default
actions could result in disruption of traffic, a further confirmation will be required by
the user.
< 5 > Clear System Uptime
Use this to clear the system uptime (time since last power up or reboot of system).
< 6 > Device Alias : FMUX
Set the device's alias name here. Must be alpha-numeric, 1~16 characters and follow
hostname rules.
< 7 > IP Configuration
Setup the networking for the management of the multiplexer.
< T > Adjust Date And Time
Set the date and time for the device's real-time clock. Follow the example.
[Local ] Ver:[1.100-1.002-0.000-0.030]
Alias : FMUX Login:admin
<< Device Configuration >>
SN :
time : [ 2015/10/12 - 13:09:59 ]
Uptime : [ 0 days - 03:59:21 ]
Power 1 [ Module | AC Power | Up ]
Power 2 [ Module | DC Power | Down ]
< Setting >
< 1 > Device Active [Enable ]
< 2 > Device Reset
< 3 > Manager Default
< 4 > System Default
< 5 > Clear System Uptime
< 6 > Device Alias : dot251
< 7 > IP Configuration
< T > Adjust Date And Time
[ ESC ] Go to previous menu. Please select an item.
------------------------------------------------------------------------------
<Y> Yes <ESC> Exit ( Optical, LAN, Port )
[Local ] Ver:[1.100-1.002-0.000-0.030]
Alias : FMUX Login:admin
<< Device -> IP Configuration >>
MAC Address : 00:02:AB:EE:EE:EE
< 1 > IP : 192.168. 0.251
< 2 > Netmask : 255.255.255. 0
< 3 > Gateway : 192.168. 0. 10
[ ESC ] Go to previous menu. Please select an item.
------------------------------------------------------------------------------
yyyy/mm/dd hh:mm:ss
Current : 2015/11/10 14:35:00