Страница 1: ...FMUX101 FMUX1001 Fiber Optical Multiplexer Standalone Rack Type Modular 16 Channel E1 T1 Data POTS plus 100M 1G Ethernet SNMP Manageable ...

Страница 2: ......

Страница 3: ...d use even if such claim alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product TRADEMARKS Microsoft is a registered trademark of Microsoft Corp HyperTerminal is a registered trademark of Hilgraeve Inc WARNING This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limi...

Страница 4: ...odels FMUX1001 16 Ch Modular E1 T1 DATA POTS with 4 port Gigabit Ethernet Switch and 850M Ethernet trunk FMUX101 16 Ch Modular E1 T1 DATA POTS with 4 port Fast Ethernet Switch and 100M Ethernet trunk This document is the first official release manual Please check CTC Union s website for any updated manual or contact us by E mail at techsupport ctcu com Please address any comments for improving thi...

Страница 5: ...ATION 21 3 3 CONNECTING TO THE FIBER MULTIPLEXER 22 3 4 CONFIGURING IN CONSOLE MODE 23 3 4 1 Login 23 3 4 2 Main Menu 23 3 4 3 Optical Configuration Menu 24 3 4 4 LAN Configuration Menu 26 3 4 5 Tributary Configuration Menu 28 3 4 6 Alarm Configuration Menu 30 3 4 7 Device Configuration Menu 31 3 4 8 SNMP Manager Configuration Menu 32 3 4 9 Log Information Menu 33 3 4 10 Store Parameters Function ...

Страница 6: ...Table of Contents ii ...

Страница 7: ... hot swappable slide in module cards The front panel provides the aggregate SFP cages LCD Menu Keys LED indicators and connectors for alarm relays order wire clear channel RS 232 and console The 4 CHANNEL E1B Tributary Card has 4 pairs of BNC 75 Ohm unbalanced connectors for E1 Line interface connections supporting four separate E1 channels at a transmission rate of 2 048Mb s transparent unframed ...

Страница 8: ...P set commands The unit operates from an internal free running oscillator The Fiber Multiplexer is completely transparent to clocking and data transmission This makes configuration of the MUX extremely easy Configuration of the Fiber Multiplexer is accomplished via local control on the LCD Menu Keys asynchronous RS 232 port with a standard VT 100 terminal via HTTP Web and Telnet or via any standar...

Страница 9: ...lowing graphic shows the major components which make up the Fiber Multiplexer It shows a unit with redundant power modules AC DC and four 4 channel tributary cards installed Figure 1 1 Fiber Multiplexer Major Components DC AC SFP 4xE1 ...

Страница 10: ...de AMI B8ZS Line Impedance Balanced 100 ohms RJ 45 Receiver sensitivity 3 to 12dB short haul Pulse Amplitude Nominal 3 00V 10 for 100 ohms Zero Amplitude 0 3V Transmit Frequency Tracking Internal Timing 50 ppm Jitter Performance According to ITU T G 824 Complies With ITU T G 703 G 704 G 706 and G 733 Interface Connectors RJ 45 Test Loops LLB Local Loop Back RLB Remote Loop Back RRLB Request Remote...

Страница 11: ...LB Remote Loop Back RRLB Request Remote Loop Back V 54 POTS Link Plain Old Telephone Service Channels 4 per module as FXO or FXS depending on module Mode Bi directional full duplex Frequency Response 300 3300Hz Coding G 711 Line Impedance unbalanced 600 ohms Transmission Medium 2 wire twisted pair 24AWG or greater Interface Connectors 4 x RJ 45 supports RJ 11 connections on center 2 pins Local Set...

Страница 12: ...alled in the module slot Phone Green Indicates the order wire is in use LNK LAN Green 4 LEDs one for each LAN port On LAN link established Flashing link with traffic Off no LAN link or port disabled Speed LAN Dual Color 4 LEDs one for each LAN port Amber On The LAN speed is 1000M FMUX1001 only Green On The LAN speed is 100M Off If link is present the LAN speed is 10M All fiber transceivers in the ...

Страница 13: ... The 4 CHANNEL E1 supports two E1 line codes AMI coding HDB3 coding The 4 CHANNEL E1 supports only transparent unframed format ie The E1 will pass through with its original framing structure completely intact 1 5 T1 DS1 Signal Structure T1 link line rate The T1 line operates at a nominal rate of 1 544Mb s T1 link line coding The basic T1 line signal is coded using either the Alternate Mark Inversi...

Страница 14: ...T1 and 1 to 4 ports of Trunk Ethernet between the units The timing scheme for typical E1 or T1 equipment is to transparently pass timing from a timing source unit on one side to a timing slaved unit on the other Each of the up to 16 available channels of the Fiber Multiplexer is independent of any other channel for framing or timing Figure 1 2 Typical Point to Point Application of Fiber Multiplexe...

Страница 15: ... 60 VDC for DC supply Allow at least 10cm 4 inch clearance at the rear and front of the Fiber Multiplexer for signal lines and interface cables 2 3 Mechanical Assembly The Fiber Multiplexer is designed for rack mount installation and only requires 1U space 1 3 4 in a standard EIA 19 inch rack It is highly recommended that the unit be placed in a rack The Fiber Multiplexer is delivered completely a...

Страница 16: ...es are installed Combinations of dual AC dual DC or AC DC are all allowed If only a single power module is installed there is no redundancy provided The Fiber Multiplexer should always be grounded through the protective earth lead of the power cable in AC installations or via the frame ground connection for DC installations A separate chassis ground is provided on the rear far right side of the ch...

Страница 17: ...agement console port and the 4 port Ethernet connections The optical interfaces are of the pluggable SFP type The two optical interfaces provide 1 1 fiber protection Figure 2 4 Front Panel Controls and Indicators 16 x E1 T1 balanced RJ 45 DC Mains Terminal Block Hot Swappable Power Modules AC Mains IEC C14 4 Hot Swappable Tributary Modules Local LCD and menu keys Optical Interfaces SFP Alarm Conta...

Страница 18: ... of 1 25Gbps is required for FMUX1001 while 155Mbps are required for FMUX101 Make sure the SFP modules chosen are suitable for the required data rate Installation CTC Union supplied SFP modules are of the Bale Clasp type The bale clasp SFP module has a bale clasp that secures the module into the SFP cage Figure 2 5 Optical Interface Removal Replacement while in service Removing a Bale Clasp SFP Mo...

Страница 19: ... connections 2 The rack mounting brackets if installed must be removed 3 Remove all tributary modules and all power modules 3 The top cover is held in place by ten screws 4 Once all ten screws are removed the top panel just lifts off The internals are now exposed Follow the procedure in reverse to re install the top panel Install the screws but at first do not tighten Make sure all ten screws are ...

Страница 20: ...crew the thumbscrew While holding the thumbscrew pull the power module straight out 4 Insert the module in the reverse order Figure 2 8 Power module Removal Replacement 2 5 4 Tributary Module Removal Replacement 1 There is no need to remove the unit from a rack 2 Remove the single flat head screw located at the top middle of tributary module 3 There is no need to unscrew the thumbscrew While holdi...

Страница 21: ... computers Windows XP computers already have a terminal emulation program called HyperTerminal However in operating systems after Windows XP such a Windows Vista Windows 7 and Windows 8 there is no such terminal emulation program In these cases we highly recommend the free emulation program TeraTerm Pro This program can be found freely on the Internet by doing a simple search For the remainder of ...

Страница 22: ...n and the application will be ready to establish communication with the Fiber Multiplexer Figure 3 1 TeraTerm Pro port settings for Fiber Multiplexer 3 3 Connecting to the Fiber Multiplexer The console port on the Fiber Multiplexer is an RS 232D interface DCE that utilizes a RJ 45 connector Use the configuration cable that is supplied with the Fiber Multiplexer or prepare a three wire RJ 45 to DB9...

Страница 23: ...assword for both users is admin 3 4 2 Main Menu After successfully logging in as admin the main menu will be displayed From this menu all configurations can be performed Operation of the interface is very straight forward The menu system requires no complex CLI commands just simply enter the menu by keying the item Upper and lower case letters work in any case FMUX1001 Manager Local Ver 1 100 1 00...

Страница 24: ... Fiber Multiplexers 3 4 3 Optical Configuration Menu This screen is both informational showing if SFP modules are installed their link state DDMI capability and fault status as well providing basic configuration of the fiber ports for ALS Auto Laser Shutdown loopback testing integrated BERT Bit Error Rate Test and detailed digital diagnostics for the installed SFP Protection Modes The Fiber Multip...

Страница 25: ...error rate channel which is constantly running and counting if there are any errors on the channel s receiver There are two menu items related to this error checking Insert one bit error will insert a single forced error from the pattern generator to increment the counter by one and a clear bit error counter to reset the count to zero SFP and Digital Diagnostics monitoring The Fiber Multiplexer su...

Страница 26: ... be set to half when speed is 1000M 5 Ingress Limit Ingress refers to packets entering the switch port The rates can only be set to 64k 1M or 10M 6 Egress Limit Egress refers to packets leaving the switch port The rates can only be set to 64k 1M or 10M 7 Default COS Each port can be assigned a Class of Service priority from 0 7 low to high Local Ver 1 100 1 002 0 000 0 030 Alias FMUX Login admin L...

Страница 27: ...is entered here The default is 0x8100 IEEE802 1ad recommends the service provider s tag type be 0x88A8 Z Go to the static VLAN configuration table There are up to 16 VLAN groups that can be defined The behavior for each of the four LAN ports for egress packets may be defined as Unmodified Untagged Tagged or non member Unmodified Although being aware the egress packet s VLAN tag will not be modifie...

Страница 28: ...ry card module 1 4 Select the individual channel from this tributary card Individual channel configuration 1 Service Enable Enable the service for this channel If disabled to traffic will pass and no alarm will be generated 2 Line Code HDB3 B8ZS Select the line coding for E1 HDB3 or AMI or for T1 B8ZS or AMI 3 Auto AIS Enable AIS is enabled by default Loss of receive E1 T1 signal will result in tr...

Страница 29: ...ons for each of the three available loopback settings LLB E1 T1 local loop back near end NE far end FE RLB E1 T1 remote loop back near end NE far end FE RRLB request E1 T1 remote loop back near end NE far end FE 0 Disable 1 LLB 2 RLB 3 RRLB Esc Exit E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 E1 T1 ...

Страница 30: ...will not issue any alarm A Power Loss This is really only applicable when two power modules are installed If enabled alarm is triggered if one of the power modules fails B Err Cnt Optical Integral BERT is always running When enabled a minor alarm is issued if a bit error is detected C Err Cnt Channel When enabled an increment in performance monitor will trigger a minor alarm D RDI When enabled a R...

Страница 31: ...e system default is performed Device Reset and System Default actions could result in disruption of traffic a further confirmation will be required by the user 5 Clear System Uptime Use this to clear the system uptime time since last power up or reboot of system 6 Device Alias FMUX Set the device s alias name here Must be alpha numeric 1 16 characters and follow hostname rules 7 IP Configuration S...

Страница 32: ...ited messages send by the Fiber Multiplexer s SNMP agent as a result of programmed alarm conditions See Alarm configuration section 3 4 5 Local Ver 1 100 1 002 0 000 0 030 Alias FMUX Login admin SNMP Manager Configuration 1 Manager Configuration 2 Trap Configuration ESC Go to previous menu Please select an item SNMP Manager Configuration Manager Setting Manager s IP Community String Access 1 192 1...

Страница 33: ...00 Anonymous admin Login Console 002 30 2015 11 10 14 52 33 040300 Anonymous admin Login Timeout Console 003 29 2015 11 10 14 39 09 020300 Anonymous admin Login Console 004 28 2015 11 10 14 38 29 070400 Port04 Remote E1 T1 RJ45 Card Found 005 27 2015 11 10 14 38 28 070300 Port03 Remote E1 T1 RJ45 Card Found 006 26 2015 11 10 14 38 28 070200 Port02 Remote E1 T1 RJ45 Card Found 007 25 2015 11 10 14 ...

Страница 34: ...S W Xmodem capable TeraTerm Pro included Upgrade firmware for version 1 00X released as FMUX1001_AP_2105xxxxxxxx BIN image file Procedure 1 Extract the upgrade package with 7 Zip or other decompression tool Connect the FMUX console port to the desktop s or laptop s COM port with DB9 to RJ45 serial adapter cable 2 Open the terminal application in the ttermpro folder and configure terminal settings ...

Страница 35: ...e boot This is the display after normal boot up waiting to login The default password is admin If the password has been forgotten use the super user back door password 1021 to login 4 This is the Main menu after logging in Select item U to enter the Firmware Upgrade menu 5 Select item 2 Upload Upgrade firmware ...

Страница 36: ... prompt If an upload does not commence within 35 seconds the upgrade will timeout Don t worry press ESC login select U and choose firmware 2 and then send the file before 35 seconds are up 6 Use the TeraTerm Pro application to transfer the image file to the FMUX for writing 7 Follow the File menu pull down File Transfer XMODEM Send Be very sure to use only the Xmodem protocol a The firmware image ...

Страница 37: ... 5 and a half minutes 9 After the image transfer is completed DO NOT ALLOW ANY POWER INTERRUPTION until the flash is erased written and verified The unit will reboot and format the image space When done the unit will reboot to the main login prompt The new version will be displayed Check the firmware version Version explanation a aaa b bbb c ccc d ddd where a aaa is the H W hardware version in thi...

Страница 38: ...e as they were performed on the local multiplexer Duplicate the settings on both multiplexers Do not forget to save the settings under the Device menu This completes the console based setting part of configuration for the fiber multiplexers With the standard SNMP option both SNMP and an easy to use Web based manager are available to the engineer for local and remote configuration and monitoring Th...

Страница 39: ...iplexer s IP address 4 3 Browser Login Start by opening a web browser application such as Chrome Firefox or Internet Explorer Enter the address of the Fiber Multiplexer in the format http xxx xxx xxx xxx where xxx xxx xxx xxx is the IP address of the Fiber Multiplexer A login username and password may or may not be required to enter the configuration The default username and password are both admi...

Страница 40: ...d time View and configure alarms Change the login password Chassis Provides a quick informational display for both local and remote units SNMP Setup the SNMP managers and trap receivers View the system log Local Device View and configure the optical aggregate the Ethernet switch and the tributary modules Remote Device Do the same remote settings if a working fiber link is established between the t...

Страница 41: ...or setting parameters rebooting defaulting and refreshing Date and Time Information and Function Keys Use this section and buttons to setup the time keeping for the Fiber Multiplexer The time may be manually set or can synchronize to PC Alarm Information Shows the current alarm status Allows for enabling or disabling alarms and sets which faults will cause an alarm action Function Key These button...

Страница 42: ...umber MAC System Information Setup networking parameters hostname and enable disable whole device Function Keys These buttons provide functions for setting parameters rebooting defaulting and refreshing Alarm Information Shows the current alarm status Allows for enabling or disabling alarms and sets which faults will cause an alarm action Function Key These buttons allow the settings to be saved S...

Страница 43: ...admin or guest user To change the password first key in the old password then key in the new password twice If the old password is keyed wrong or if the two new passwords don t match the action will be aborted The password must contain only alpha numeric a z A Z 0 9 with a maximum length of 16 characters ...

Страница 44: ...ultiplexers Local Information Display the version serial number MAC power and alarm statuses Optical An overview of optical ports SFP installed exist is SFP DDM type the link status of optical and any reported SFP fault LAN The link state is displayed for each of the four LAN ports Port Slot Displays the card type in each slot Port and whether the channels are enabled yes or disabled no ...

Страница 45: ...rings act as passwords and are case sensitive Click the Set Parameters button after making any changes 4 3 7 SNMP Log Information This informational page is an internal system log that can hold up to 100 log entries The Clear All button will clear all log entries The time the log is cleared will be recorded If power fails to the Fiber Multiplexer all log information is lost ...

Страница 46: ...wo aggregate optical ports that can provide redundant transmission in the event one single path becomes unstable or un useable 0 Auto Non Revert The default setting When working path transitions to other optical link it will remain there even if the downed link is restored will not revert 1 Auto Revert When this mode is set the path will switch back when the downed link is restored 2 Manual OP1 3 ...

Страница 47: ...k near end NE far end FE RRLB Request optical remote loop back near end NE far end FE Integral BERT Within the optical transmission is a pattern generator that feeds a bit error rate channel which is constantly running and counting if there are any errors on the channel s receiver There are two menu items related to this error checking Insert one bit error will insert a single forced error from th...

Страница 48: ...mbo frame 10240 bytes support Use the Set Parameters button to save changes and the Refresh button to reload the page information Tag based QoS uses a three bit priority tag as defined in IEEE802 1p The three bit priority results in 8 priority levels from 0 lowest to 7 highest Internally the switch only supports two bits priority or 0 lowest to 3 highest The mapping function is used to map the 8 8...

Страница 49: ...l ingress packets on each of the ports The switch supports up to 16 VLAN groups out of a possible 4095 Configure QinQ for ports 1 4 When enabled this function defines the outer tag added to all packets that egress the port VLAN Table This is the static VLAN table There are up to 16 VLAN groups that can be defined The behavior for each of the four LAN ports for egress packets may be defined as Unmo...

Страница 50: ...mode Status The channel statuses for Link AIS TxFault and performance are shown for each of the 4 channels Configuration For each channel the service may be enabled or disabled the line code selected between HDB3 B8ZS or AMI the AIS enabled or disabled and loopback type selected Performance monitoring count can be cleared individually for each channel Performance Monitor Note The only performance ...

Страница 51: ...he remote Fiber Multiplexer can be provisioned via the same simple web interface Refer to the configuration steps in 4 4 1 through 4 4 3 to configure the remote Fiber Multiplexer Note Optical loop back is not available from the remote device Optical loop back may only be performed from local device ...

Страница 52: ...Chapter 4 Web Based Management 52 ...

Страница 53: ...This page left blank intentionally ...

Страница 54: ......