Chapter 3. Operation
22
Table 3.1 Control Functions
Item Control
Switch
Function
1
Loc dig loopbk
The local digital loop back switch causes the
local ETU01-Plus to loop E1 received data to
its transmitter.
2
Loc ana loopbk
The local analog loop back switch causes the
local ETU01-Plus to loop transmitter output
back to its receiver. The transmitter sends 'all
ones' data to the line. This loop back may also
be activated from the DTE when the data port
loop back test function is set to ENA (enable).
3
Rem loopbk
The remote loop back switch causes the
remote ETU01-Plus to loop E1 received data to
its transmitter. This loop back may also be
activated from the DTE when the data port loop
back test function is set to ENA (enable).
4
Pattern
The pattern switch causes the ETU01-Plus to
send and receive a 511 test pattern. If errors
are encountered, the Error LED indicator lights.
Table 3.2 LED indicators
Item Indicator Color
Meaning
1
PWR
Green
ON when power is on.
2
TD
Green
ON when SPACE is being transmitted.
Flashing when data is transmitted.
3
RD
Green
ON when SPACE is being received.
Flashing when data is received.
4
RTS
Green
ON when terminal activates Request To
Sent.
5
DCD
Green
ON when a valid receive signal is present.
6
Tx CLK Loss
Red
ON when transmitted clock is lost.
7
Signal Loss
Red
ON when received signal is lost.
8
Sync Loss
Red
ON when received frame sync is lost.
9
Alarm
Red
ON when E1 link has an alarm. (Include:
BPV error / CRC4 error /
Frame slip / All ones / Remote alarm).
10
Error
Red
ON when Pattern switch is activated and bit
errors are detected.
11
Test
Red
ON when the ETU01-Plus is in any loop
back mode or Pattern is depressed.
Содержание ETU01-Plus
Страница 1: ...ETU01 Plus ETU01U Plus Single V 35 Port G 703 E1 Access Unit ...
Страница 2: ......
Страница 4: ......
Страница 19: ...Chapter 2 Installation 19 Figure 2 3 ETU01 Plus DIP Switches Version 1 1G PCB ...
Страница 40: ...Appendix C Interface Connections 40 This page left blank intentionally ...
Страница 43: ......
Страница 44: ......