CTC Union CombiAir 12-UK 1x230V Скачать руководство пользователя страница 25

Radiator

Another word for heating element. They must be filled with water in order
to be used with CTC CombiAir .

Refrigerant

Substance that circulates around a closed circuit in the heat pump and
that, through pressure changes, evaporates and condenses. During evap-
oration, the refrigerant absorbs heating energy and when condensing
gives off heating energy.

Return pipe

The line in which the water is transported back to the heat pump from
the house heating system (radiators/heating coils).

Return temp

The temperature of the water that returns to the heat pump after releasing
the heat energy to the radiators/heating coils.

Safety valve

A valve that opens and releases a small amount of liquid if the pressure is
too high.

Shuttle valve

A valve that can send liquid in two directions. A shuttle valve that enables
liquid to be sent to the climate system, when the heat pump produces
heating for the house, and to the hot water heater, when the heat pump
produces hot water.

Silent operation

A mode where the maximum level for the output is limited to achieve a
noise reduction from the heat pump.

Supply temperature

The temperature of the heated water sent by the heat pump to the heating
system.

Water heater

Container where domestic water is heated.

25

CTC CombiAir

Chapter 5 |

Glossary

Содержание CombiAir 12-UK 1x230V

Страница 1: ...User manual LEK LEK LEK UN CTC CombiAir 6 8 12 16 UK 1x230V Air water heat pump UHB EN 2024 1 16230562...

Страница 2: ......

Страница 3: ...pecific information 11 CTC CombiAir An excellent choice 12 2 The heat pump the heart of the house 12 Heat pump function 14 Control of CTC CombiAir 15 Maintenance of CTC CombiAir 20 3 Disturbances in c...

Страница 4: ...tion date Installer Always state the serial number Certification that the installation is carried out according to instructions in CTC s installer manual and applicable regulations ___________________...

Страница 5: ...involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Rights to make any design or technical modifications are reserved CT...

Страница 6: ...tallation TIP This symbol indicates tips on how to facilitate using the product Marking The CE mark is obligatory for most products sold in the EU regardless of where they are made CE Classification o...

Страница 7: ...serial number for CTC CombiAir can be found on the side of the foot LEK DATA Serial number Caution You need the product s 12 digit serial number for servicing and support 7 CTC CombiAir Chapter 1 Impo...

Страница 8: ...mmissioned and serviced in accordance with the manufacturers instructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist can be...

Страница 9: ...sure that the installer has fully completed the Benchmark Checklist in the end of the Installation Instructions supplied with the product and that you have signed to say that you have received a full...

Страница 10: ...e correctly earthed polarised and in accordance with the relevant standards Currently this is BS 7671 Heating System The installation of the heat pump should follow best practice as covered in the fol...

Страница 11: ...l heat Excellent properties for CTC CombiAir Efficient twin rotary compressor Efficient twin rotary compressor that operates at temperatures down to 20 C Intelligent control CTC CombiAir connected to...

Страница 12: ...5 C 45 C Expansionsventil Kompressor A D F H I B C E G HDWLQJ PHGLXP ULQH 5HIULJHUDQW YDSRUDWRU RQGHQVHU SDQVLRQ YDOYH RPSUHVVRU HDW VRXUFH The temperatures are only examples and may vary between diff...

Страница 13: ...gas that is produced during boiling is routed into an electrically powered compressor When the gas is compressed the pressure increases and the gas s temperature increases considerably from approx 5...

Страница 14: ...coZenith i360 H L or control module CTC EcoLogic M L See the relevant manual for more information During installation the installation engineer adjusts the necessary settings for the heat pump in the...

Страница 15: ...eaves snow or anything else regularly throughout the year You should be vigilant during windy conditions and or in the event of snow as the grilles can become blocked Also check that drain holes in th...

Страница 16: ...ask your installer if you are unsure Silent operation The heat pump can be set to silent operation which reduces the heat pump s noise level The function is useful when CTC CombiAir must be placed in...

Страница 17: ...ss the year Month Jan Feb Mar April May June July Aug Sep Oct Nov Dec of annual consumption Increasing the indoor temperature one degree increases power consump tion by approx 5 Domestic electricity I...

Страница 18: ...Operation 1 h day 4 months a year 100 800 Passengercompartmentheater Operation 1 h day 4 months a year These values are approximate example values Example A family with 2 children live in a house with...

Страница 19: ...than it would thereafter After 1 2 years the heating curve should be adjusted again as well as the offset heating curve and the building s thermostat valves because the heating system as a rule requi...

Страница 20: ...e that the air flow to CTC CombiAir is not blocked by foreign objects Check that CTC CombiAir does not have any external damage Ice build up in the fan grille and or fan cone on CTC CombiAir If proble...

Страница 21: ...4 Technical data Detailed technical specifications for this product can be found in the In staller Manual 21 CTC CombiAir Chapter 4 Technical data...

Страница 22: ...the building s output requirement This means that the heat pump covers the whole building s output requirement down to this temperature Charge coil A charge coil heats the domestic hot water tap water...

Страница 23: ...n comfort In most cases the heat pump notes malfunctions and indicates this with alarms in the display Domestic hot water The water one showers in for example Double jacketed tank A heater with domest...

Страница 24: ...that transfers heat energy from one medium to another without mixing mediums Examples of different heat exchangers include evapor ators and condensers Heat factor Measurement of how much heat energy t...

Страница 25: ...s to the heat pump after releasing the heat energy to the radiators heating coils Safety valve A valve that opens and releases a small amount of liquid if the pressure is too high Shuttle valve A valv...

Страница 26: ...long power cuts 16 Installation data 4 M Maintenance of CTC CombiAir 15 In event of long power cuts 16 Regular checks 15 Saving tips 16 Silent operation 16 Marking 6 P Power consumption 17 R Regular c...

Страница 27: ......

Страница 28: ...WS name Gemensamt WS version a795 working edition Publish date 2020 06 10 13 04 Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc heating com 16230562...

Отзывы: