Operation / Technical Manual
NORM-O-TEMP, Model 111Z
Page 46 of 81
5-3.
Maintenance of the NORM-O-TEMP
®
Exterior & Vents – Cleaning Instructions
The NORM-O-TEMP
®
unit is constructed of powder coated steel with a plastic top that
should be cleaned quarterly with water and mild detergent solution. For cleaning and
disinfecting, always use conventional hospital-approved topical equipment cleaners and
disinfectants that do not contain alcohol. Avoid alcohol and other strong, undiluted
disinfectants. These may cause staining of the device’s outer skin.
Thoroughly wipe down device with a damp cloth to remove any residue from cleaning
solutions. Ensure that all inaccessible cracks and crevices on the Norm-O-Temp
®
unit
are reached during cleaning.
Wipe the vents on the front and rear of the unit. Ensure all debris is removed and there
is no blockage of any vent on the unit. Vents must be free of obstructions.
In addition, ensure that all accessories associated with the NORM-O-TEMP
®
system,
including extension hoses, are cleaned quarterly as well.
5-4.
Maintenance of the Hyper-Hypothermia Blanket / Pad(s)
This section describes the general maintenance for the reusable and disposable
blankets/pads. General maintenance tasks include cleaning, draining, and storing the
reusable blankets/pads.
5-4.1.
Cleaning / Maintenance of Reusable Blanket / Pad(s)
Cincinnati Sub-Zero reusable blankets/pads are constructed from biocompatible
polyurethane/urethane. Stains and debris can be wiped away with mild soap
and water. For cleaning, always use conventional hospital-approved topical
cleaners and disinfectants that do not contain alcohol. Avoid alcohol or strong,
undiluted disinfectants. These may cause staining of the device’s outer skin.
Thoroughly rinse product with clear water to remove any residue from cleaning
solutions. DO NOT use gas sterilization or autoclaving for cleaning and
disinfecting the blankets/pads.
To drain the water from the reusable blankets/pads simply shut off power to the
unit and allow the water to drain from the blanket/pad back into the NORM-O-
TEMP
®
unit.
To store PLASTIPAD blankets/pads, loosely coil the hose lengthwise into the
center of the blanket/pad. Fold the blanket lengthwise into the center, 1/3 from
the left side and 1/3 from the right side. Do not fold the blankets/pads width-
wise, as doing so will crimp the tubing.
To store Gelli-Roll blankets/pads either lay them flat or roll the blanket/pad. Do
not fold the Gelli-Roll blankets/pads.
Disposal of blankets/pads are done in a means consistent with hospital policy
protocol for patient contact items.
Содержание NORM-O-TEP 111Z
Страница 14: ...Operation Technical Manual NORM O TEMP Model 111Z Page 14 of 81 Figure 1 NORM O TEMP unit Front View ...
Страница 16: ...Operation Technical Manual NORM O TEMP Model 111Z Page 16 of 81 Figure 2 NORM O TEMP unit Left Side View ...
Страница 18: ...Operation Technical Manual NORM O TEMP Model 111Z Page 18 of 81 Figure 3 NORM O TEMP unit Rear View ...
Страница 20: ...Operation Technical Manual NORM O TEMP Model 111Z Page 20 of 81 Figure 4 NORM O TEMP unit Right Side View ...
Страница 22: ...Operation Technical Manual NORM O TEMP Model 111Z Page 22 of 81 Figure 5 NORM O TEMP unit Model 111Z Top View ...