INSTALLATION INSTRUCTION
WINDMASTER WITH SPARKGUARD
FOR BUSH FIRE ZONES UP TO AND INCLUDING BAL 29 ONLY.
Edmonds is a business division of CSR Building Products Limited ABN 55 008 631 356
10 Stanton Road, Seven Hills NSW 2147
Telephone 1300 858 674
www.edmonds.com.au
Global
-
Mark
.
com
.
au®
Q
ua
lit
y M
ana
gement
.
ISO
90
01
Publish dat
e: 0
1/1
4
Doc ref: I-034-B
STEP 7:
Take the replacement assembly and
insert into the housing. It may need
to be tilted to allow the fan blades to
clear the support bracket.
STEP 8:
Turn the assembly until the holes
in the motor bracket align with the
holes in the support bracket.
STEP 9:
Using the T-25 Torx screwdriver fix
the motor assembly bracket to the
housing support backet with the four
(4) screws that were removed earlier.
Note that the screws will take more
effort than usual as they go in as
they will be forming a thread in the
metal.
INSTALLATION INSTRUCTION
Replacing Motor/Fan/Bracket assembly in the Maestro/Sentinel
STEP 10:
Using the 2mm flat screwdriver
reconnect the motor wires to the
terminal block. Ensure the correct
polarity.
The blue motor wire connects to the
black wire, and the red motor wire
connects to the black/white wire.
STEP 11:
Turn the power to the Maestro/
Sentinel back on.
Take care when inserting the assembly to
avoid damage to the fan blades