background image

INSTALLATION INSTRUCTION 

WINDMASTER WITH SPARKGUARD 

FOR BUSH FIRE ZONES UP TO AND INCLUDING BAL 29 ONLY.

Edmonds is a business division of CSR Building Products Limited ABN 55 008 631 356

 

10 Stanton Road, Seven Hills NSW 2147
Telephone 1300 858 674    

www.edmonds.com.au

Global

-

Mark

.

com

.

au®

Q

ua

lit

y M

ana

gement 

.

 ISO

 90

01

 

Publish dat

e: 0

1/1

Doc ref:  I-034-B

STEP 7:

Take the replacement assembly and 

insert into the housing. It may need 

to be tilted to allow the fan blades to 

clear the support bracket.

STEP 8:

Turn the assembly until the holes 

in the motor bracket align with the 

holes in the support bracket.

STEP 9:

Using the T-25 Torx screwdriver fix 

the motor assembly bracket to the 

housing support backet with the four 

(4) screws that were removed earlier.

Note that the screws will take more 

effort than usual as they go in as 

they will be forming a thread in the 

metal.

INSTALLATION INSTRUCTION

Replacing Motor/Fan/Bracket assembly in the Maestro/Sentinel

STEP 10:

Using the 2mm flat screwdriver 

reconnect the motor wires to the 

terminal block. Ensure the correct 

polarity. 

The blue motor wire connects to the 

black wire, and the red motor wire 

connects to the black/white wire.

STEP 11:

Turn the power to the Maestro/

Sentinel back on.

Take care when inserting the assembly to 

avoid damage to the fan blades

Отзывы: