INSTALLATION INSTRUCTION
WINDMASTER WITH SPARKGUARD
FOR BUSH FIRE ZONES UP TO AND INCLUDING BAL 29 ONLY.
Edmonds is a business division of CSR Building Products Limited ABN 55 008 631 356
10 Stanton Road, Seven Hills NSW 2147
Telephone 1300 858 674
www.edmonds.com.au
Global
-
Mark
.
com
.
au®
Q
ua
lit
y M
ana
gement
.
ISO
90
01
Publish dat
e: 0
1/1
4
Doc ref: I-034-B
STEP 1:
Turn off power to the Maestro/
Sentinel.
STEP 2:
Using a 2mm flat screwdriver;
disconnect the motor from the
terminal block.
STEP 3:
Either remove the Maestro/Sentinel
from the roof and turn over OR
perform the replacment of the
motor assembly from underneath an
installed Maestro/Sentinel.
INSTALLATION INSTRUCTION
Replacing Motor/Fan/Bracket assembly in the Maestro/Sentinel
STEP 4:
Using the T-25 Torx screwdriver
remove the four (4) screws that
secure the motor assembly bracket
to the housing support bracket.
TOOLS REQUIRED
2mm flat screwdriver
T-25 Torx Screwdriver or bit