CSL Eickhoff Скачать руководство пользователя страница 20

Eickhoff Diagnostic Charging Station 

20 / 30 

November 2015 

– Issue 1.6 

On selecting “OK”, the following screen is displayed: 
 

 

 
Use the touchpad on the right to clear or enter numbers in the field on the left which 
is highlighted. Move the highlight to other fields that are required to be altered. 
 
When happy with the entry, click the OK button to send to the handset. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Eickhoff

Страница 1: ...sue 1 6 Eickhoff Diagnostic Charging Station User Manual Issue 1 6 New Bluetooth module and Software Controlled Systems Limited Ryder Close Swadlincote Derbyshire DE11 9EU England TEL 44 0 1283 216231...

Страница 2: ...4 Screen showing connected handsets 11 5 5 Testing for correct operation of handset keys 12 5 6 Radio Handset Display Highlighted 13 5 7 Updating Radio Handset Software 14 5 8 Updating the Radio Hands...

Страница 3: ...ff Diagnostic Charging Station Features Search for radio handsets and display up to six on the colour display The radio handsets need to be on charge for the search to be successful Charge up to six r...

Страница 4: ...ternal supply between 90 264 volts and 47 63 Hz The Diagnostic Station is powered by an Intel core2 duo processor incorporated inside the unit The unit is equipped with a touch screen for easy onsite...

Страница 5: ...l connections on the right hand side of the unit are shown below The external connections on the left hand side of the unit are shown below RF Power meter connector BT antenna 12v DC output Ethernet p...

Страница 6: ...Eickhoff Diagnostic Charging Station 6 30 November 2015 Issue 1 6 Cooling Fan ON OFF Switch Power IEC Socket Fuse Holder Below...

Страница 7: ...used in hazardous areas The parameters of the external power supply must fall within the range detailed in Description above The unit must be connected to earth This apparatus must only be installed o...

Страница 8: ...5 Operating the Diagnostic Charging Station 5 1 Powering Unit On The unit is powered on by operating the switch on the left hand side of the unit and will automatically load the diagnostic display sho...

Страница 9: ...search to be successful Any Machine Radio Receiver within range of the Radio Handsets to be tested MUST be switched OFF if the handset is logged on to it Handsets online to a Radio Receiver will not b...

Страница 10: ...November 2015 Issue 1 6 5 3 Select which Handsets are required On this screen simply select using the touch screen the handsets you wish to connect Once highlighted simply click the OK button and the...

Страница 11: ...ostic Charging Station 11 30 November 2015 Issue 1 6 5 4 Screen showing connected handsets A maximum of 6 radio handsets can be displayed at once Note If a wire bound handset is connected then this is...

Страница 12: ...Eickhoff Diagnostic Charging Station 12 30 November 2015 Issue 1 6 5 5 Testing for correct operation of handset keys The above shows 2 handset keys depressed all keys are monitored in this way...

Страница 13: ...Display Highlighted To highlight a radio handset displayed on the screen touch the radio handset panel Touch the panel again to de select it With a detected radio handset highlighted the update softwa...

Страница 14: ...set highlighted all the buttons at the top of the screen become available for that handset Touch Update Software button A password is then required to continue and a password box is displayed The Ente...

Страница 15: ...gnostic Charging Station 15 30 November 2015 Issue 1 6 Selecting OK shows a select file box containing a list of available files Select the required file to update the radio handset Select OK to start...

Страница 16: ...ckhoff Diagnostic Charging Station 16 30 November 2015 Issue 1 6 A progress bar indicates the current updating progress as shown below On completion touch the OK button to return from the update scree...

Страница 17: ...highlighted all the buttons at the top of the screen become available for that handset Touch Update Font Chip button A password is then required to continue and a password box is displayed The Enter...

Страница 18: ...Station 18 30 November 2015 Issue 1 6 On selecting OK the download automatically starts as shown below On completion touch the OK button to return from the update screen Note This update takes approxi...

Страница 19: ...et highlighted all the buttons at the top of the screen become available for that handset Touch Set S N H W Version button A password is then required to continue and a password box is displayed The E...

Страница 20: ...ng OK the following screen is displayed Use the touchpad on the right to clear or enter numbers in the field on the left which is highlighted Move the highlight to other fields that are required to be...

Страница 21: ...op offline from the diagnostic station The handset will remain offline until either a SEARCH FOR HANDSET is instigated or the RECONNECT HANDSETS is pressed 2 Radio Handsets shown online After a Radio...

Страница 22: ...off Diagnostic Charging Station 22 30 November 2015 Issue 1 6 Offline handsets are attempted up to 3 times to be reconnected If successful the handset will come online again If not it will stay as off...

Страница 23: ...ndset display is always situated in the bottom RH corner of the screen Serial number software version and hardware version in brackets is displayed The keys can be tested the same as the radio handset...

Страница 24: ...e diagnostic station or any machine radio to give the correct RF power readings Typical RF Power Readings The value on RF4 MAX setting is approx 50 70mW and typically around 65mW The handset transmitt...

Страница 25: ...Before checking the RF power the RF power level on the handset should be set to RF4 MAX see the Eickhoff Bi Di Radio Mk2 User Manual for details The RF power meter is calibrated to read Bluetooth powe...

Страница 26: ...t required in normal use Note The Ethernet port can also be used to view the webpage on a connected MK2 or SMK2 Machine Radio Receiver using Internet Explorer which can be found on the Diagnostic Char...

Страница 27: ...ckhoff Diagnostic Station exe to old Eickhoff Diagnostic Station exe 5 From the pen drive E copy Eickhoff Diagnostic Station exe to D Eickhoff Diagnostic 6 Copy any new software hex file EHRv _ hex an...

Страница 28: ...connect Machine Radio X2 CANBUS to Diagnostic Station CANBUS connector 3 Connect 2 x Radio C514974 to Diagnostic Station charger ports and power up Ensure one Radio is setup as Left Hand and the other...

Страница 29: ...Eickhoff Diagnostic Charging Station 29 30 November 2015 Issue 1 6...

Страница 30: ...side therefore the units should not be disassembled by the end user A 3 Amp anti surge HRC fuse is fitted below the IEC mains socket and must only be replaced by the same type and rating If the remova...

Отзывы: