SIGNATURE 2 SERIES
SIGNATURE 2 SERIES
- Electrical Connection -
1. Connect the power supply to the control valve and plug into a 115 volt / 60 Hz receptacle.
Note:
Do not plug into an outlet controlled by a wall switch or pull chain that could inadvertently be
turned off.
-Pressurizing The System -
2. Slowly rotate handle of the bypass valve to the SERVICE position.
3. Open the nearest faucet to evacuate air from plumbing lines.
4. Check for leaks! If water is observed leaking from bypass, o-rings on valve body may not be seat-
ed properly.
5. After air is evacuated from plumbing lines, turn off faucet.
- Initial Control Valve Operation -
1. Advance control valve to BACKWASH (cycle 1) position and allow water to run to drain for 3 to 4
minutes.
Warning:
Close handle on bypass prior to selecting the backwash position. After backwash position
has been established, slightly open valve on bypass to evacuate air from the media tank.
Fully open bypass valve when all air is depleted. This procedure will prevent media form
being uplifted into control valve.
2. Advance control valve to RAPID RINSE (cycle 3) position and allow water to run to drain for 3 to 4
minutes.
3. Advance control valve to SERVICE (cycle 0) position.
Electronic Connections
P - Power Supply
B - Powered in Backwash Cycle Only
S - Powered in Entire Regeneration Cycle