CSI Fiberlink 5018A Скачать руководство пользователя страница 10

Page 10

Fiberlink® 5018A User’s Manual

Fiberlink® 5018A

  Modes of Operation:

On the 5018A card-cage model, there are three DIP switch banks located on the 

printed circuit card. Switch Bank S1 sets the Mode of Operation, Switch Bank S2 

sets the Baud Rate (RS-485 Data Format) and Switch Bank S3 sets the Alarm.

  Setting the MODE DIP switch 

Switch setting example

Low Speed or High Speed Operation:

For all protocols, positions 1 and 2 of the MODE DIP switch (S1) MUST be set  
as either Low Speed or High Speed Operation as follows:

 
Low speed mode (DC to 2.1 mbps):  
Position 1 = ON, Position 2 = OFF

High speed mode (10 kbps to 10 mbps):  

 

Position 1 = OFF, Position 2 = ON 

For RS-232, the data rate is limited to 200 kbps. For RS-422/485, the data rate is as above.
The universal data transceiver will not operate properly if  positions 1 and 2 are both set to either ON or OFF.

DIP Switch Settings

1

2

3

4

5

6

7

8

O P E N

1

2

3

4

5

6

7

8

O P E N

 

Switch ON (CLOSED)

 Switch Off (OPEN)

1

2

3

4

5

6

7

8

O P E N

Содержание Fiberlink 5018A

Страница 1: ...rd Cage User s Manual Fiberlink 5018A Universal Data Transceiver for the Fiberlink 6000A Card Cage The Fiberlink 5018A Universal Data Transceiver digitally transmits RS 232 422 485 data over multimode...

Страница 2: ...tion Theory 6 Installation Instructions 7 Signal and Power Connections 8 DIP Switch Settings 10 Modes of Operation 10 T R Time Settings Baud Rate 15 Alarm Switch Settings 16 Optical Fiber Types Suppor...

Страница 3: ...standard data related signals in accordance with EIA specifications May be easily user configured for the desired protocol including mixed protocols Transmitter and receiver may be configured differen...

Страница 4: ...e of being configured for operation in many different modes we strongly suggested that you consult the appropriate sections of this manual 5018A Quick Installation Card Cage Locking Screws LED Indicat...

Страница 5: ...DC logic 0 or logic 1 continuously In the high speed mode of operation the system will operate properly with all duty cycles from 50 50 to 70 30 General Information The Universal Data Transceiver is f...

Страница 6: ...light off any protocol may be used in conjunc tion with any other protocol thereby allowing the transceiver to be used as a data converter as well as a general data transceiver In addition provision i...

Страница 7: ...ions beginning on page 10 Note As provided from the factory the unit is set for RS 232 point to point 3 Plug the unit into any free position in a model 6000A card cage 4 Connect the 5018A units togeth...

Страница 8: ...RS 232 Signal Connections Description EIA Designation Terminal Positions Chassis Ground Common AA 1 Transmit Data BA input 2 Receive Data BB output 4 Signal Common AB 1 All other terminal block posit...

Страница 9: ...should not be connected for this format RS 485 4 Wire Signal Connections Chassis Ground 1 Transmit Data input 2 Transmit Data input 3 Receive Data output 4 Receive Data output 5 RTS Enable when used i...

Страница 10: ...ion For all protocols positions 1 and 2 of the MODE DIP switch S1 MUST be set as either Low Speed or High Speed Operation as follows Low speed mode DC to 2 1 mbps Position 1 ON Position 2 OFF High spe...

Страница 11: ...P E N SeePage10 Mode T R RS 232 Drop and Repeat 1 2 3 4 5 6 7 8 O P E N 1 through 6 Off 1 2 3 4 5 6 7 8 O P E N SeePage10 Mode T R When using this mode of operation any RS 232 driver not transmitting...

Страница 12: ...P E N Switch 6 ON 1 2 3 4 5 6 7 8 O P E N SeePage10 Mode T R In this mode the input to terminal 6 must be high for the unit to transmit data and low to receive data RS 485 2 Wire Drop and Repeat RTS...

Страница 13: ...N See Baud Rate settings on page 15 1 2 3 4 5 6 7 8 O P E N SeePage10 Mode T R RS 485 4 Wire Point to Point RTS Enable 1 2 3 4 5 6 7 8 O P E N All Off 1 2 3 4 5 6 7 8 O P E N SeePage10 Mode T R In th...

Страница 14: ...o Point Data Derived T R 1 2 3 4 5 6 7 8 O P E N See Baud Rate settings on page 15 1 2 3 4 5 6 7 8 O P E N SeePage10 Mode T R RS 485 4 wire Drop and Repeat Data Derived T R 1 2 3 4 5 6 7 8 O P E N See...

Страница 15: ...2K 110 us On On On Off Off Off NA NA DIP Switch Settings 1 2 3 4 5 6 7 8 O P E N 2400 1 2 3 4 5 6 7 8 O P E N 4800 1 2 3 4 5 6 7 8 O P E N 76 8k 1 2 3 4 5 6 7 8 O P E N 115 2k 1 2 3 4 5 6 7 8 O P E N...

Страница 16: ...x at the end of the model numbers as follows Fiber Size Connector 850nm 1300nm 50 62 5 MM ST 1 3 8 10 SM FCPC N A 7 A 6300 adapter is available to allow the 1 and 3 versions of the 5018A model to be u...

Страница 17: ...respect to position 1 RS 422 terminal block position 2 negative with respect to position 3 to prevent loop lock up RS 485 operation does not have the above restriction due to the fact that it is in th...

Страница 18: ...tic cable should be treated with moderate care as it does contain thin fragile strands of glass Notes Regarding Fiber Optic Cable Multimode fiber optic cable contains an optical fiber with a light car...

Страница 19: ...f these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the Fiberl...

Страница 20: ...d that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink 6615 a visible light...

Страница 21: ...g free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of profits or goodwill CSI shall not be obligated to replace or repair equipment tha...

Страница 22: ...Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It can be u...

Страница 23: ...Page 23 Fiberlink 5018A User s Manual Fiberlink 5018A Notes...

Страница 24: ...istered trademarks of Communications Specialties Inc CSI and the triangle designs are trademarks of Communications Specialties Inc P N 121459 Rev F If y ba 2005 Spectra Vision Productions Inc Communic...

Отзывы: