![CSI CARDPIN1 Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/csi/cardpin1/cardpin1_installation-manual_2692608044.webp)
Proximity Readers
Installation Guide
38
CSI Readers
PR-105
This proximity reader is an indoor Wall Switch Reader that is architecturally designed to
blend into executive office decor. This reader mounts directly on any standard U.S.A.
metal or plastic single-gang electrical box, or on a flat wall. It may be mounted on a metal
surface with a slight loss of read range. Read range is 0–4" (0–10 cm) with the PC-121
Card. Use the steps in
“Proximity Reader Installation with the Indala ARE-142,” below
.
PR-120 and PR-122
The PR-120 proximity reader is an indoor Medium Range Reader. The PR-122 is an
outdoor Medium Range Reader. They are designed for longer read range and bi-direc-
tional reading. They may be concealed behind extra thick building materials or buried
in a wall. They will not operate on a solid metal surface. Read range is 0–15" (0–38 cm)
with the PC-121 Card. Use the steps in
“Proximity Reader Installation with the Indala
Proximity Reader Installation with the Indala ARE-142
The PR-103, PR-105, PR-120 and PR-122 require the ARE-142 Remote Electronics
Module to connect their output cables to the DPUs. Use the following steps to connect
the output cables to the ARE-142 and to the DPU (see
Connecting To the ARE-142
Use the following steps to install the field output cables from a PR-103, PR-105, PR-120
or PR-122 to an ARE-142 (see
1.
Connect the blue wire to TB1-A on the ARE-142.
2.
Connect the green wire to TB1-B on the ARE-142.
3.
Connect the brown wire to TB1-C on the ARE-142.
4.
Connect the white wire to TB1-D on the ARE-142.
5.
Connect the black wire to TB1-E on the ARE-142.
6.
Connect the red wire to TB1-F on the ARE-142.
7.
Connect the shield to TB1-E on the ARE-142.
Connecting the ARE-142 Output Cables
Use the following steps to install the field output cables from an ARE-142 to a breakout
box or directly to the DPU-7920 at the TB3 or TB4 (see
).
1.
Connect the white wire (
Data-1
) from terminal 4, TB2 of the ARE-142 to terminal
3 on the breakout box or DPU-7920.
2.
The blue wire (Beeper) from terminal 6, TB2 of the ARE-142 is
not
connected to
the breakout box or DPU-7920.