Appendix B. Example Programs
B-16
EndIf
NextScan
EndProg
B.4 Heater Program Examples
The following programs are written for a SR50AH-L configured for SDI-12.
Detailed information about the heater is provided in Appendix
(p. F-1)
TABLE B-7. Wiring for CR1000 and CR6 Heater Example Programs
107-L Air Temperature Sensor Wiring
Wire Color
Sensor Wire Description
CR1000 Wire Channels
CR6 Wire Channels
Black
Voltage-excitation input
VX1
U2
Red
Analog-voltage output
SE1
U1
Purple
Bridge resistor lead
⏚
⏚
Shield
EMF shield
⏚
⏚
SR50A-L Configured for SDI-12 Wiring
Wire Color
Sensor Wire Description
CR1000 Wire Channels
CR6 Wire Channels
Red
Power source
12V
12V
Green
SDI-12 I/O
C1
C1
White
Not used
G
G
Black
Ground
G
G
Shield
Shield/Earth ground
G
G
SR50AH Heater Power Cable
Wire Color
Heater Wire Description
CR1000 Wire Channels
CR6 Wire Channels
Black
Power source
SW-12
SW12-1
White
Power ground
G
G
Shield
Shield/Earth ground
⏚
⏚
CRBasic Example B-6. CR1000 Heater Program Example
'CR1000
'This program contains a number of features not found in Short Cut.
'
'The initial distance value from the SR50A head to the ground is
'measured by setting the flag SR50A_MID to TRUE. Set this flag after
'installing the SR50A in the field. Setting this flag will initiate
'a measurement cycle and the resulting value stored as the initial
'distance. The initial distance is used to calculate snow depth.
'The PreserveVariables instruction is used to store the initial
'distance in non-volatile memory. If power is lost at the site the
'initial distance value will be restored.'
'A control flag is used to initiate the SR50A measurement cycle. This
Содержание SR50A
Страница 2: ......
Страница 6: ......
Страница 30: ...SR50A Series Sonic Ranging Sensors 20...
Страница 32: ......
Страница 53: ...Appendix B Example Programs B 21 CallTable Daily CallTable Hour NextScan EndProg...
Страница 54: ...Appendix B Example Programs B 22...
Страница 56: ......
Страница 78: ...Appendix E Tera Term QuickStart E 10...
Страница 83: ......