CS Instruments VA 520 Скачать руководство пользователя страница 44

  

 

Maintenance / warranty 

 
VA 520 Bi directional English V1.21 

 

Page 44 of 45 

12

 

Maintenance

 

The sensor head should be checked regularly for dirt and cleaned if necessary. Should dirt, dust or oil 
accumulate on the sensor element, a deviation will occur in the measuring value. An annual check is 
recommended. Should the compressed air be heavily soiled this interval must be shortened. 

13

 

Cleaning of the sensor head

 

The sensor head can be cleaned by carefully moving it in warm water with a small amount of washing-
up liquid. Avoid physical intervention on the sensor (e.g. using a sponge or brush). If soiling cannot be 
removed, service and maintenance must be carried out by the manufacturer. 

14

 

Re-Calibration

 

If no customer specifications are given then we recommend to carry out calibration every 12 months. 
For this purpose the sensor must be sent to the manufacturer. 

15

 

Spare parts and repair

 

For reasons of measuring accuracy spare parts are not available. 
If parts are faulty, they must be sent to the supplier for repair. 
 
If the measuring device is used in important company installations, we recommend keeping a spare 
measuring system ready. 

16

 

Calibration

 

According to DIN ISO certification of the measuring instruments we recommend to calibrate and if 
applicable to adjust the instruments regularly from the manufacturer. The calibration intervals should 
comply with your internal specification. According to DIN ISO we recommend a calibration interval of 
one year for the instrument VA 520. 
 
On request and additional payment, calibration-certificates could be issued.  

The precision is given due to use DKD-certified flow meters and verifiable

 

17

 

Warranty

 

If you have reason for complaint we will of course repair any faults free of charge if it can be proven 
that they are manufacturing faults. The fault should be reported immediately after it has been found 
and within the warranty time guaranteed by us. Excluded from this warranty is damage caused by 
improper use and non-adherence to the instruction manual. 
 
The warranty is also cancelled once the instrument has been opened - as far as this has not been 
mentioned in the instruction manual for maintenance purposes - or if the serial number in the 
instrument has been changed, damaged or removed. 
 
The warranty time for the VA 520 is 12 months. If no other definitions are given the accessory parts 
have a warranty time of 6 months. Warranty services do not extend the warranty time. 
 
If in addition to the warranty service necessary repairs, adjustments or similar are carried out the 
warranty services are free of charge but there is a charge for other services such as transport and 
packaging costs. Other claims, especially those for damage occurring outside the instrument, are not 
included unless responsibility is legally binding. 
 

After sales service after the warranty time has elapsed 

We are of course there for you even after the warranty time has elapsed. In case of malfunctions, 
please send us the instrument with a short-form description of the fault. Please do not forget to 
indicate your telephone number so that we can call you in case of any questions. 
 

Содержание VA 520

Страница 1: ...0 Bi directional English V1 21 Page 1 of 45 EN English Instruction manual Consumption counter VA 520 for bi directional measurements Stationary Flow and consumption measurement for compressed air and...

Страница 2: ...ctioning of the VA 520 are only guaranteed in case of careful observation of the described instructions and notes Sales Office South Gesch ftsstelle S d Zindelsteiner Str 15 D 78052 VS Tannheim Tel 49...

Страница 3: ...ments 9 6 2 Inlet outlet runs 9 6 3 Installation of VA 520 10 6 4 Displayhead Position 10 7 Flow measuring ranges 11 7 1 Flow for different gases 11 8 Dimensions 12 8 1 With measurement section and sc...

Страница 4: ...up 28 10 3 2 2 Modbus TCP Optional 29 10 3 2 2 1 Network Setup DHCP 29 10 3 2 2 2 Network Settings static IP 30 10 3 2 2 3 Modbus TCP Settings 31 10 3 2 3 Modbus Settings register 2001 2005 32 10 3 2...

Страница 5: ...the resulting heat flow to the passing medium gas With the calorimetric measurement method based on the measurement principle the operating temperature and pressure of the medium have no influence on...

Страница 6: ...fer no guarantee for the suitability for any other purpose and are not liable for errors which may have slipped into this operation manual We are also not liable for consequential damage resulting fro...

Страница 7: ...ressure up to 16 bar special version PN 40 40 bar Power supply 18 to 36 VDC Power consumption max 5W Digital output RS 485 Modbus RTU Optional Ethernet also PoE and MBus Analog output 4 20 mA see chap...

Страница 8: ...m h High Speed 0 215 m h VA 520 with integrated 1 meas section Low Speed 4 20 mA 0 75 m h Standard 0 145 m h Max 0 290 m h High Speed 0 355 m h VA 520 with integrated 1 1 4 meas section Low Speed 4 2...

Страница 9: ...outlet section L2 Slight curve bend 90 12 x D 5 x D Reduction pipe narrows towards the meas section 15 x D 5 x D Expansion pipe expands towards the meas section 15 x D 5 x D 90 bend or T piece 15 x D...

Страница 10: ...ng nut is tightened to a torque of 25 30 Nm Tightness of the connection must be checked and ensured 6 4 Displayhead Position Fastening screws The Position of the Displayhead is twistable by 180 e g in...

Страница 11: ...20 1185 2030 2810 High Speed 130 105 210 350 635 875 1430 2455 3405 Nitrogen N2 Low Speed 25 20 40 70 130 180 295 505 705 Standard 50 40 80 135 240 335 550 945 1305 Max 100 80 160 270 485 670 1100 188...

Страница 12: ...A mm VA 520 1 4 DN 8 13 7 8 5 194 137 176 6 166 3 R 1 4 15 VA 520 1 2 DN 15 21 3 16 1 300 210 177 0 166 3 R 1 2 20 VA 520 3 4 DN 20 26 9 21 7 475 275 179 8 166 3 R 3 4 20 VA 520 1 DN 25 33 7 27 3 475...

Страница 13: ...95 65 4 x 14 VA 520 3 4 DN 20 26 9 21 7 475 275 218 8 166 3 105 75 4 x 14 VA 520 1 DN 25 33 7 27 3 475 275 223 8 166 3 115 85 4 x 14 VA 520 1 1 4 DN 32 42 4 36 0 475 275 263 3 166 3 140 100 4 x 18 VA...

Страница 14: ...D DIR MBus MBus Colours pulse cables 0553 0106 5 m 0553 0107 10 m brown white blue black grey Legend VB Negative supply voltage 0 V Pulse Pulse for consumption VB Positive supply voltage 18 36 VDC smo...

Страница 15: ...itch to On It must be ensured that the connection plugs are still plugged and the gasket is installed correctly Alternatively a 120R resistor can be installed in the plug between pin 2 and pin 4 9 2 2...

Страница 16: ...optional PoE Connector plug B Connection cable M12 x coded 8 pole M12 x coded to RJ45 Data LINES 1 2 und 3 4 PoE LINES 5 6 und 7 8 2 8 1 3 5 4 6 7 M12 x 1 Connection cable Cat 6 PoE Power over Etherne...

Страница 17: ...Operation VA 520 Bi directional English V1 21 Page 17 of 45 10 Operation Up OK The operation of the VA 520 is done by the two capacitive key buttons Up and Enter...

Страница 18: ...Version Modbus Id Page No SW Version Gas Status Info 0 000 Switching to pages 2 5 or back by pressing key After switching on the VA 520 the initialized screen is displayed followed by the main menu 0...

Страница 19: ...under Sensor Setup Advanced AV Time Flow direction blue Average max Value Flow direction green Average max Value Total counter Velocity Direction blue Average max Value Velocity Direction green Avera...

Страница 20: ...s password protected Selection of a menu item or to change a value is done with the key a final move to the chosen menu item or takeover of the value change needs the confirmation by pressing the key...

Страница 21: ...Setup Setup Sensor Setup 10 3 1 1 Input change tube diameter For VA 520 not adjustable suspended as voted on included measuring section with corresponding pipe diameter 53 1 mm For changes first selec...

Страница 22: ...hen key OK Select with the key the correct unit and then confirm selection by pressing 2x OK Entering changing the consumption counter via button select the respective position and activate the positi...

Страница 23: ...he unit for the respective measurement value first select by pressing the field of the measurement value and activate it with OK Selection of the new unit with In case the quantity of units selectable...

Страница 24: ...e temperature and reference pressure are 20 C 1000 hPa All volume flow values m h and consumption values indicated in the display are related to 20 C and 1000 hPa according to ISO 1217 intake conditio...

Страница 25: ...he key the correct unit and then confirm selection by pressing 2x OK Input change of the value by selecting the respective position with button and entering by pressing button OK By pressing the posit...

Страница 26: ...etup Advanced Filtertime Setup Sensor Setup Advanced AV Time Under item Filtertime an attenuation can be defined Input values of 0 10000 in ms are possible The time period for averaging can be entered...

Страница 27: ...By pressing the position value is incremented by 1 Confirm the input with OK and activate next number position Leave menu with button Back Men punkt mit Taste anw hlen und anschlie end mit Taste OK au...

Страница 28: ...released and set the internal DIP Switch to On Alternatively a 120R resistor can be installed in the plug between pin 2 and pin 4 It must be ensured that the connection plugs are still plugged and the...

Страница 29: ...ification and description of the Modbus protocol is free to download on www modbus org Supported Modbus commands functions Command Code Description Function Code 3 Read holding register Function code...

Страница 30: ...Subnet and Gateway selection keys must be selected and activated with OK The first data field of the selection in this case the IP address is then marked red Confirm with OK the corresponding input me...

Страница 31: ...and then key OK Select the desired position by pressing the and select with OK button Change values by pressing the values takeover by pressing OK Input for the port is done analogue By means of the...

Страница 32: ...tting Read Write Unit Comment 2001 2000 2 UInt16 Modbus ID 1 R W Modbus ID 1 247 2002 2001 2 UInt16 Baudrate 4 R W 0 1200 1 2400 2 4800 3 9600 4 19200 5 38400 2003 2002 2 UInt16 Parity 1 R W 0 none 1...

Страница 33: ...tung Gr n 10141 10140 Richtung Blau 1149 1148 4 Float Flow in ltr min R Richtung Gr n 10149 10148 Richtung Blau 1157 1156 4 Float Flow in Nltr min R Richtung Gr n 10157 10156 Richtung Blau 1165 1164 4...

Страница 34: ...n 10299 10298 Richtung Blau 1305 1304 4 UInt32 Consumption kg before comma x R Richtung Gr n 10305 10304 Richtung Blau 1311 1310 4 UInt32 Consumption kWh before comma x R Richtung Gr n 10311 10310 Ric...

Страница 35: ...layed The galvanically isolated output can be defined as pulse or alarm output Selection of field Relay Mode with key and change modus by pressing key OK For alarm output following units could be chos...

Страница 36: ...The required password length is 4 digits Please select with button a figure and confirm it with OK Repeat this 4 times With the last figure could be deleted Password input have to be inserted twice C...

Страница 37: ...ightness The actual adjusted backlight brightness is showed in the graph Backlight By activation Dimming after and entering a time a display dimming could be set With Rotate Screen the display informa...

Страница 38: ...und Flow to the channel CH 1 To make changes first select the value item with button and confirm Moving between the different measurements values or to deactivate the 4 20mA with setting to unused by...

Страница 39: ...ed before for value settings Using CLR clears up the complete settings at once For Auto on the max scaling is calculated based on the inner tube diameter max measurement range and the reference condit...

Страница 40: ...Info Settings Info Run Time 2d 21h 23m 12s Vin 23 8V Temp 35 8 92 7 m s 600m h 20 C 53 1 mm 23 C 10 Here you get a brief description of the sensor data incl the calibration data Under Details you are...

Страница 41: ...1 with Unit Consumption m Value 2 with Unit Flow m h Consumption m Value 3 with Unit Gas temperature C All Values could be changed preset in production or with CS Service software Order No 0554 2007 T...

Страница 42: ...hich the next recalibration is recommended is internally entered When this date is reached a message appears in the display with the status message CAL Note The measurement will continue without inter...

Страница 43: ...message Internal Error the sensor has an internal read error on e g EEProm AD converter etc detected I Temp out of Range At media temperatures outside the specified temperature range the status messag...

Страница 44: ...ne year for the instrument VA 520 On request and additional payment calibration certificates could be issued The precision is given due to use DKD certified flow meters and verifiable 17 Warranty If y...

Страница 45: ...CE Conformity VA 520 Bi directional English V1 21 Page 45 of 45...

Отзывы: