1.  Safety instructions 

 
Observe measuring ranges of the sensors! 
Observe the admissible storage and transportation temperature as well as the 
permitted operating temperature (e. g. protect the instrument from direct 
insolation) 

 

Adjustments and calibrations should only be carried out by qualified employees 
from the measurement and control technology branch. 

 

We offer you to take back the instruments DS 52, which you would like to 
dispose of. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

 

The manufacturer cannot be held liable for any damage which occurs as a 
result of non-observance or non-compliance with these instructions. Should the 
device be tampered with in any matter other than a procedure which is 
described and specified in the manual, the warranty is cancelled and the 
manufacturer is exempt from liability. 

 

CS Instruments GmbH offers no guarantee for the suitability for any other 
purpose and is not liable for errors which may have slipped into this operation 
manual. CS Instruments GmbH is also not liable for consequential damage 
resulting from the delivery, capability or use of this device. 

 

Initiation (electrical connection) 

When operating electrical instruments it is unavoidable that certain components 
are energised dangerously. Work at electrical installations or equipment is only 
allowed to be carried out by electrical technicians or instructed staff under the 
guidance and suvervision of an electrical technician according to the electrical 
regulations. 

 

Warning 

Any non-observance of the warning notes may cause grievous bodily harm or 
property damages. Qualified staff has to be well familiar with all warnings 
according to this instruction manual. The correct and safe operation is subject 
to a proper transport, professional installation and accurate initiation. The 
following notes on safety are applied in order to stress safety relevant 
procedures in this instruction manual - every note is marked by a corresponding 
icon.  

 

This symbol means: 

Note!

 

"Note"

 marks activities or procedures which have a fundamental influence 

on correct operation. Any non-observance may possibly lead to subsequent 
damages.

 

This symbol means: 

Warning!

 

"Warning"

 indicates activities or procedures which may lead to a safety 

risk for persons and property damages in case of non-observance.

 

 

 

 

Содержание 0500 0008

Страница 1: ...V1_03_2016 1 Instruction Manual Digital Display DS 52 in wall housing Order no 0500 0008 for 0 4 20 mA sensors...

Страница 2: ...gh standard products every year There are a few good reasons for doing so The cost performance ratio reliable quality at a fair price We have the ideal solutions for your measuring tasks based on our...

Страница 3: ...the delivery capability or use of this device Initiation electrical connection When operating electrical instruments it is unavoidable that certain components are energised dangerously Work at electr...

Страница 4: ...of CS Instruments sensors AC Power 230 VAC 50 Hz Attention Mains voltage NC und COM are closed in case of alarm exceeding voltage drop sensor break A bridge circuit is inserted ex factory For signal...

Страница 5: ...ensor Terminal connector M12 7 8 9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 1 2 3 4 5 FA 515 Braun brown Blau blue CS Sensor Terminal connector M12 A bridge circuit is...

Страница 6: ...or input is configurated on our premises according to the customers specification in the order Sensors with 0 4 20 mA current signal are connected as follows V max 24 VDC 100 mA A bridge circuit is in...

Страница 7: ...9 101112131415 1 2 3 4 5 6 Sensor 230 VAC A1 2 A1 1 PE N L V GND I I I SIG 0 1 2 5 4 3 Netzanschlussleitung Supply cable gr n gelb green yellow blau blue braun brown grau grey schwarz black Lampe lamp...

Страница 8: ...2 nOr alters press shortly HY 2 2 0 alters press shortly rEv rEv With alarm threshold 1 scaling up with scaling down nOr Normal means Alarm 1 in case of threshold exceeding rEv Reverse means Alarm 1...

Страница 9: ...with and whether you want to connect a sensor with 0 20 mA signal or with 4 20 mA signal 4 mA 0 20 mA 500 With and you can set the lower scaling value 4 mA resp 0 mA of your sensor With and you set th...

Страница 10: ...instrument has been opened as far as this has not been mentioned in the instruction manual for maintenance purposes or if the serial number in the instrument has been changed damaged or removed The wa...

Страница 11: ...or sensors with 0 20 mA or 0 4 20 mA signal Connectable in 2 3 or 4 wire technologie possible with 24 VDC supply Burden analogue input 100 Ohm Accuracy analogue input max 20 A typical 10 A Sensor supp...

Страница 12: ...ogue sensor input for sensors with 4 20 mA or 0 20 mA signals 2 alarm relays change over contact 250 VAC max 3 A alarm values freely adjustable 0500 0008 Options Option for DS 52 LED display Supply 24...

Страница 13: ...V1_03_2016 13 Notes...

Страница 14: ...55 Harrislee Phone 49 0 461 700 2025 Fax 49 0 461 700 2026 E Mail info cs instruments com www cs instruments com Sales office South Germany CS Instruments GmbH Zindelsteiner Stra e 15 78052 VS Tannhei...

Отзывы: