background image

Indigo PSU Manual R1.1 

 

Crystal Vision

 

Indigo PSU Manual R1.1 

1

  

16/06/2010 

Contents 

1

 

Introduction 2

 

2

 

Installation 4

 

General Safety Summary 

4

 

2.1

 

Crystal Vision PSU modules 

5

 

Mains Combiner 

7

 

Inserting and removing power supplies 

9

 

Power supply relay connections 

11

 

3

 

Trouble shooting 

12

 

Reading LED status and active display messages 

12

 

Replacing the mains input fuses 

13

 

Replacing the PSU-150i-48V fuse 

14

 

Indigo 1-DP 

15

 

3.1

 

Frequently asked questions 

16

 

4

 

Specification 17

 

 

 

Revision 1  Indigo PSU-160i and dual PS-55i information added  28-02-07

Содержание Indigo PS-55i

Страница 1: ...tation Road East Whittlesford Cambridge CB22 4WL England E mail sales crystalvision tv Website www crystalvision tv Tel 44 0 1223 497049 Fax 44 0 1223 497059 Power supplies for the Indigo frames Inclu...

Страница 2: ...5 Mains Combiner 7 Inserting and removing power supplies 9 Power supply relay connections 11 3 Trouble shooting 12 Reading LED status and active display messages 12 Replacing the mains input fuses 13...

Страница 3: ...sor which communicates with the front panel display processor referred to as a PIC such information as power rail voltage levels 5 75V and 6 0 V and the PSU fan speed The PSU also stores its own seria...

Страница 4: ...Crystal Vision Introduction Indigo PSU Manual R1 1 3 16 06 2010 The Indigo 2 Crystal Vision frame with front control panel open The Indigo 4 Crystal Vision frame with front control panel open...

Страница 5: ...o Refer all servicing to qualified service personnel Apart from procedures described in this manual there are no user serviceable parts within the frame If the frame requires any other servicing it sh...

Страница 6: ...PSU 150i 160 watt PSU 160i and dual 55 watt for the Indigo 1 DP PS 55i The 150 watt PSU is also available with 48Vdc input PSU150i 48V PSU 75i 150i 150i 48V top view PSU 160i Dual PS 55i Note If two...

Страница 7: ...and position will not fit into the left hand and visa versa Reconfiguring a PS 55i to its opposite handing requires the power supply module to be repositioned on its carrier board The removal of two f...

Страница 8: ...o function in the event of one of the two mains inputs failing the PSU CMB or PSU CMB2 mains combiner is fitted to the vacant slot in the upper PSU bay The mains combiner has been designed to be narro...

Страница 9: ...ed personnel only To reduce risk of electric shock do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so Refer all servicing to qualifi...

Страница 10: ...p and the front panel PSU FAN LED will change from green to red Removing the PSU fan assembly Lower PSU 75i front view In addition to the PSU and fan LEDs on the front control panel there is also a re...

Страница 11: ...for the number of PSUs installed to prevent redundant PSU warnings Refitting the fan assembly To replace the PSU fan assembly proceed as follows Offer up the fan assembly ensuring that the two lugs fi...

Страница 12: ...Pin number relay common Remote 4 pin 14 open on fault Remote 4 pin 23 close on fault Remote 4 pin 5 Indigo 4 Lower Power Supply Relay Connections Description pin number relay common Remote 8 pin 14 op...

Страница 13: ...eration Change the panel fan Indigo 4 maybe upper or lower fan PSU Fan Yell Grn Red None Psu fan speed low Normal operation Change PSU fan Indigo 4 maybe upper or lower fan PSU Indigo 1 Yell Grn Red N...

Страница 14: ...l involve dismantling the module See replacing PSU 150i 48V fuse Note The red LED built into the front of the vertical PCB on the LHS of the PSU will flash repeatedly on for one second and off for one...

Страница 15: ...powered PSU module from the frame Using a pozi headed cross bladed screwdriver remove the six screws securing the transparent insulation cover from the under side of the PSU Remove the four further sc...

Страница 16: ...does not have externally accessible mains fuses They are situated on the Power supply modules To service these fuses it is necessary to remove the power supply module from the frame PS 55i showing mai...

Страница 17: ...lugged in correctly Try replacing the fan What should I do if the FRONT FAN LED is red Check that the front control panel fan is plugged in correctly Try replacing the fan What should I do if the UPPE...

Страница 18: ...volts 47 to 400Hz Operating conditions 0 to 40 degrees C non condensing Ventilation front to sides without air filters Weight PSU 75i 610g PSU 150i 730g PSU 150i 48Vdc 610g PSU 160i PS 55i 2 required...