Crystal Vision
Control Descriptions
6 Control Descriptions
The controls of ADP 310 are accessible from the front panel, the board edge or from
Crystal Vision’s ‘VisionWeb’ software. The description of controls used in this manual is
based on VisionWeb GUI screen grabs but the path to locate controls via the front
panel or board edge follows the same logic. For instance, in the VisionWeb GUI the
‘Reference Present’ indicator is located in the ‘
Reference Status’
group of the ‘
Status’
menu. To find the same control using the card edge or front panel follow the path
Status->Ref Status
to the
Ref Present
control.
VisionWeb GUI controls are accessed by menus at the bottom of the page which, when
selected, offer sub-menus containing a number of controls. Some controls are
simulated LEDs that are used to show status, others are check boxes, buttons or
sliders which change various ADP 310 settings.
The description of the menus are in the order shown in the GUI i.e.
STATUS, DELAY, INVERT & MONO, AUDIO GAIN, AOP OUTPUT ROUTER / AES
OUTPUT ROUTER, PRESETS, RESETS
,
GPO5 ALARMS, GPO6 ALARMS,
SILENCE ALARM DELAY.
(Note that the AOP OUTPUT ROUTER tab is only available whenever a 3G-AOP2
piggyback is fitted. If a DIOP4 piggyback is fitted instead, the tab displayed becomes
AES OUTPUT ROUTER.)
Each menu is shown with a screen grab and description of each control’s function.
Some menus and some controls are specific to the type of piggyback option boards
fitted. Screen grabs from both configurations are used to show menus and controls
specific to each.
Status Menu
Status
Display presence, standard and status of reference video signal.
Reference Present
On when valid Black and Burst or tri-level video input present.
Reference Standard
Shows reference video standard e.g. 625/50, 525/60, 525/59.94.
Sub PCB Type
Displays type of piggyback fitted in front and rear positions i.e.
None, DIOP4, 3G-AIP2, 3G-AOP2.
ADP 310 User Manual R1.2
23