OPERATING INSTRUCTIONS.
THE APPLIANCE DATA BADGE IS POSITIONED ON THE FRONT BOTTOM SECTION
OF THE APPLIANCE AND CARIES THE CONTROL KNOB POSITIONS.THE FULL
LIGHTING PROCEDURE IS AS FOLLOWS.
1.PUSH CONTROL KNOB IN AS FAR AS POSSIBLE ON GAS CONTROL
2.TURN KNOB ANTICLOCKWISE TO IGNITION POSITION STILL KEEPING KNOB IN
AS FAR AS POSSIBLE.
3.THE IGNITION BUTTON WILL IGNITE THE PILOT WITH THIS OPERATION
KEEP
THE KNOB PRESSED IN FOR 15 SECONDS.
IF THE PILOT FAILS TO LIGHT TURN
THE CONTROL KNOB CLOCKWISE TO THE OFF POSITION, WAIT 3 MINUTES AND
REPEAT THE PROCEDURE
4.WHEN THE PILOT FLAME IS ALIGHT THE CONTROL KNOB SHOULD BE ALLOWED
TO SPRING OUT SLIGHTLY.TURN THE KNOB FULLY ANTICLOCKWISE TO THE HIGH
POSITION.THE PILOT FLAME WILL THEN IGNITE THE MAIN BURNER.THE PILOT
FLAME CAN BE VIEWED TO THE RIGHT OF THE FIRE JUST BEHIND THE FRONT
LOG SET
5.THE APPLIANCE CAN BE ADJUSTED BETWEEN HIGH AND LOW BY MOVING THE
CONTROL KNOB TO SUIT,THE KNOB WILL NEED TO BE DEPRESSED SLIGHTLY TO
MOVE FROM LOW HIGH AND IGNITION.
6.TO TURN THE FIRE OFF,DEPRESS THE KNOB SLIGHTLY AND TURN IT TO
PILOT POSITION.
7.TO COMPLETELY EXTINGUISH THE FIRE DEPRESS THE KNOB SLIGHTLY AND
TURN TO OFF POSITION.
8.SHOULD THE SPARK IGNITION FAIL TO OPERATE.TURN THE CONTROL KNOB TO
THE OFF POSITION AND WAIT 3 MINUTES.TURN THE KNOB TO THE IGNITION
POSITION AND THEN LIGHT THE PILOT WITH A TAPER.”LIGHTING THE PILOT
WITH A TAPER IS AN EMERGENCY MEASURE ONLY AND THE APPLIANCE SHOULD
BE SERVICED AS SOON AS POSSIBLE”.AND THEN PROCEED AS STATED IN
PARAGRAPHS 2/7.
IMPORTANT .THIS APPLIANCE IS FITTED WITH AN OXYGEN DEPLETION SENSOR
INCORPORATED INTO THE PILOT BODY.SHOULD THE FIRE REEATEDLY
EXTINGUISH ITSELF THEN SPECIALIST ADVISE SHOULD BE SOUGHT,AS THIS
MAY INDICATE SPILLAGE INTO THE ROOM OF COMBUSTION PRODUCTS.
OFF
PILOT
IGN
LOW
HIGH
GB/IE CAT1
2H
G20
AT
20mbar hot
HEAT INPUT HIGH 6.8Kw LOW 3.8Kw gross
SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE
JET CAT82/380 BRAY
CRYSTAL FIRES1 BECHERS DRIVE L9 5AY
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE RULES IN FORCE AND USED ONLY IN A SUFFICIENTLY
VENTILATED SPACE .CONSULT INSTRUCTIONS BEFORE
INSTALLATIONS AND USE OF THIS APPLIANCE
FIG 1
CLEANING
BEFORE CLEANING ANY PART OF THE FIRE ,ENSURE THAT THE GAS IS
TURNED OFF AND FIRE IS COOL.
IMPORTANT
THE PAINT AND STAINLESS FINISH ARE DURABLE BUT WILL BE
DAMAGED IF PLASTER,CEMENT,OR WALLPAPER PASTE COMES IN
CONTACT WITH IT
ISSUE 1
18