OPERATING INSTRUCTIONS. 
 

THE APPLIANCE DATA BADGE IS POSITIONED ON THE FRONT BOTTOM SECTION 
OF THE APPLIANCE AND CARIES THE CONTROL KNOB POSITIONS.THE FULL 
LIGHTING PROCEDURE IS AS FOLLOWS. 
1.PUSH CONTROL KNOB IN AS FAR AS POSSIBLE ON GAS CONTROL 
2.TURN KNOB ANTICLOCKWISE TO IGNITION POSITION STILL KEEPING KNOB IN 
AS FAR AS POSSIBLE. 
3.THE IGNITION BUTTON WILL IGNITE THE PILOT WITH THIS OPERATION 

KEEP 

THE KNOB PRESSED IN FOR 15 SECONDS.

IF THE PILOT FAILS TO LIGHT TURN 

THE CONTROL KNOB CLOCKWISE TO THE OFF POSITION, WAIT 3 MINUTES AND 
REPEAT THE PROCEDURE 
4.WHEN THE PILOT FLAME IS ALIGHT THE CONTROL KNOB SHOULD BE ALLOWED 
TO SPRING OUT SLIGHTLY.TURN THE KNOB FULLY ANTICLOCKWISE TO THE HIGH 
POSITION.THE PILOT FLAME WILL THEN IGNITE THE MAIN BURNER.THE PILOT 
FLAME CAN BE VIEWED TO THE RIGHT OF THE FIRE JUST BEHIND THE FRONT 
LOG SET 
5.THE APPLIANCE CAN BE ADJUSTED BETWEEN HIGH AND LOW BY MOVING THE 
CONTROL KNOB TO SUIT,THE KNOB WILL NEED TO BE DEPRESSED SLIGHTLY TO 
MOVE FROM LOW HIGH AND IGNITION. 
6.TO TURN THE FIRE OFF,DEPRESS THE KNOB SLIGHTLY AND TURN IT TO 
PILOT POSITION. 
7.TO COMPLETELY EXTINGUISH THE FIRE DEPRESS THE KNOB SLIGHTLY AND 
TURN TO OFF POSITION. 
8.SHOULD THE SPARK IGNITION FAIL TO OPERATE.TURN THE CONTROL KNOB TO 
THE OFF POSITION AND WAIT 3 MINUTES.TURN THE KNOB TO THE IGNITION 
POSITION AND THEN LIGHT THE PILOT WITH A TAPER.”LIGHTING THE PILOT 
WITH A TAPER IS AN EMERGENCY MEASURE ONLY AND THE APPLIANCE SHOULD 
BE SERVICED AS SOON AS POSSIBLE”.AND THEN PROCEED AS STATED IN 
PARAGRAPHS 2/7. 

IMPORTANT .THIS  APPLIANCE IS FITTED WITH AN OXYGEN DEPLETION SENSOR 
INCORPORATED  INTO THE PILOT BODY.SHOULD THE FIRE REEATEDLY 
EXTINGUISH ITSELF THEN SPECIALIST ADVISE SHOULD BE SOUGHT,AS THIS 
MAY INDICATE SPILLAGE INTO THE ROOM OF COMBUSTION PRODUCTS. 
 

OFF

PILOT
IGN

LOW

HIGH

GB/IE CAT1

2H

G20 

AT 

20mbar hot 

HEAT INPUT HIGH 6.8Kw LOW 3.8Kw gross

SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE

JET CAT82/380 BRAY

CRYSTAL FIRES1  BECHERS DRIVE L9 5AY

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE
WITH THE RULES IN FORCE AND USED ONLY IN A SUFFICIENTLY
VENTILATED SPACE .CONSULT INSTRUCTIONS BEFORE
INSTALLATIONS AND USE OF THIS APPLIANCE

 

 

FIG 1 

 

 

 

CLEANING 

BEFORE CLEANING ANY PART OF THE FIRE ,ENSURE THAT THE GAS IS 
TURNED OFF AND FIRE IS COOL. 
 

IMPORTANT 

THE PAINT AND STAINLESS FINISH ARE DURABLE BUT WILL  BE 
DAMAGED IF PLASTER,CEMENT,OR WALLPAPER PASTE COMES IN 
CONTACT WITH IT 
 

ISSUE 1 

18

Содержание SAPHIRE

Страница 1: ...RS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I2H FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G B AND I E INSTALLA...

Страница 2: ...300 mm from floor level to shelf height Floor level 600mm SIZES INCLUDING TRIM PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START INSTALLING THE APPLIANCE KEEP THIS BOOKLET HANDY FOR FUTURE REF...

Страница 3: ...OPRIETARY FIRE SURROUND WITH 100 DEGREES C RATING no hearth is required if installed a minimum height of 300mm to shelf height A as shown on page 2 THE CHIMNEY OR FLUE UNLESS NEW MUST BE SWEPT BEFORE...

Страница 4: ...NFORM TO BS8423 2002 FIREGUARDS FOR FIRES AND HEATING APPLIANCES FOR DOMESTIC USE SPECIFICATION INSTALLATION REQUIREMENTS PRE CAST FLUES A PRECAST FLUE CONFORMING TO THE REQUIREMENTS OF BS 1289 PART 1...

Страница 5: ...BUILDERS OPENING A MINIMUM OF 400mm HIGH AND 350mm WIDE WITH A MINIMUM DEPTH OF 150mm TO ALLOW SUFFICIENT VOLUME OF DEBRIS COLLECTION TO OBTAIN THIS DEPTH IT IS NECESSARY TO REMOVE THE CHAIRBRICK ANY...

Страница 6: ...IT IS SEALED AT THE TOP AND BOTTOM OF THE EXISTING BRICK OR STONE CHIMNEY NOTE ANY OF THE ABOVE FLUES MUST NOT BE RESTRICTED BY DAMPERS OR REGISTER PLATES THE FLUE MUST SERVE ONLY ONE APPLIANCE AND N...

Страница 7: ...HEARTH NO PURPOSE MADE HEARTH IS REQUIRED WITH THIS GAS APPLIANCE PROVIDING IT IS WALL MOUNTED AT A MINIMUM HEIGHT OF 300mm TO THE SHELF HEIGHT AS SHOWN BELOW MINIMUM 300 mm SKIRTING BOARD ISSUE 1 7...

Страница 8: ...ESTABLISHED IF ALL THE SMOKE IS NOT DRAWN INTO THE FLUE PRE HEAT THE FLUE WITH A BLOW TORCH OR SIMILAR AND RE CHECK IF THERE IS ANY UNCERTAINTY EXAMINE FOR THE CAUSE AND IF NECESSARY SEEK EXPERT ADVI...

Страница 9: ...ON SWITCH CHECK THAT THE ELECTRODE IS SPARKING CONTINUE SPARKING UNTIL PILOT IGNITION IS ESTABLISHED TURN THE GAS CONTROL KNOB ON TO THE HIGH POSITION AND ALLOW TO RUN FOR FIVE MINUTES CHECK THE INLET...

Страница 10: ...ING POINTS AS SHOWN THE SEVEN ROUND FUEL PIECES SIT WITH FLAT BASES DOWN THE FUEL PIECES ARE LEVEL WITH THE FRONT FIBRE AND DO NOT OVERLAP ON TO THE BURNER THEY ARE PLACED ON TOP OF LOCATING PINS SHOW...

Страница 11: ...FUEL PIECE SITS ON ROUND FUEL PIECES WITH BRANCH LOOKING TO REAR AND TOUCHING RIGHT PILLAR ON REAR MATRIX IT IS POSITIONED HORIZONTAL BETWEEN THE TWO SMALL PIECES ON LEFT AND RIGHT LEFT SMALL LOG PIEC...

Страница 12: ...SITS TO THE RIGHT OF THE CENTRE TOP PIECE THIS TIME WITH BRANCH TO REAR AS SHOWN AGAIN THE RIGHT BRANCH FUEL PIECE SHOULD HAVE A GAP OF 20mm BETWEEN IT AND CENTRE FUEL PIECE ISSUE 1 12 taper THE APPLI...

Страница 13: ...THE TEST SHOULD BE REPEATED WITH ALL THE DOORS TO THAT ROOM OPENED AND THE EXTRACTOR FAN RUNNING FITTING TRIMS FIT THE TRIM WITH MAGNETS PLACED ON THE VERTICAL SIDE FLANGES OF THE FIRE BACK PANEL OFF...

Страница 14: ...FUEL WHICH SHOULD ONLY BE REPLACED AS A COMPLETE SET WITH NO EXTRA FUEL ADDED 1 REMOVAL OF FUEL PIECES REMOVE LOOSE FUEL PIECES REMOVE FRONT FIBRE BASE REMOVE MAIN FIBRE BASE 2 REPLACEMENT OF GAS CONT...

Страница 15: ...THAT THE GAS IS TURNED OFF AND FIRE IS COOL BLACK PAINT USE ONLY CLEAN DAMP CLOTH DO NOT USE ANY CLEANING AGENTS IMPORTANT THE PAINT AND STAINLESS FINISH ARE DURABLE BUT WILL BE DAMAGED IF PLASTER CEM...

Страница 16: ...ECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK AINTREE LIVERPOOL L9 5AY SAPHIRE DECORATIVE FUEL EFFECT GAS FIRE THIS APPLIANCE IS CAT I2H FOR USE WITH NATURAL GAS ONLY G20 AT 20mbar IN G B AND I E USER...

Страница 17: ...VICING INSTUCTIONS SUPPLIED SERVICING SHOULD BE CARRIED OUT REGULARLY BY A COMPETENT PERSON EG A C O R G I MEMBER IN ACCORDANCE WITH THE CURRENT EDITION OF THE GAS SAFETY INSTALLATION AND USE REGULATI...

Страница 18: ...N 7 TO COMPLETELY EXTINGUISH THE FIRE DEPRESS THE KNOB SLIGHTLY AND TURN TO OFF POSITION 8 SHOULD THE SPARK IGNITION FAIL TO OPERATE TURN THE CONTROL KNOB TO THE OFF POSITION AND WAIT 3 MINUTES TURN T...

Страница 19: ...THE FUEL BED AND BURNER THIS MUST BE REMOVED BY REMOVING FUEL AND BRUSHING ANY DEPOSITS WITH A SOFT BRUSH AND VACUUMING THE BURNER THEN REPLACE FUEL USING THE FOLLOWING PROCEDURE ONLY USE FUEL PIECES...

Страница 20: ...LANE THE TWO SMALL FUEL PIECES SIT HORIZONTAL ON LEFT AND RIGHT AS SHOWN BETWEEN ROUND FUEL PIECES AND REAR MATRIX FRONT FUEL PIECE SITS ON ROUND FUEL PIECES WITH BRANCH LOOKING TO REAR AND TOUCHING R...

Страница 21: ...ITS TO RIGHT OF LEFT TOP PIECE THIS TIME BRANCH IS TO THE FRONT AS SHOWN THERE SHOULD BE A GAP OF 20mm BETWEEN THE TWO TOP BRANCH FUEL PIECES RIGHT TOP FUEL PIECE SITS TO THE RIGHT OF THE CENTRE TOP P...

Страница 22: ...AILS POSITION TAPER AS SHOWN AND OPERATE THE APPLIANCE AS NORMAL THEN SEEK ADVISE TO HAVE THE FAULT REPAIRED FROM A CORGI APPROVED ENGINEER ISSUE 1 22 taper CUSTOMER SPARE PARTS FUEL BED SAPH001 MAIN...

Страница 23: ...N FURTHER LEFT TO ON POSITION SHOWN IN FIGURE 1 ABOVE PILOT GAS FLOWS AND MAIN BURNER FLOWS IN ACCORDANCE TO THE FLAME SETTING KNOB B AS SHOWN IN FIG 1 ABOVE ADJUSTING THE FLAME SETTINGS TO TURN THE F...

Страница 24: ...EPLACE BATTERIES ALLOW FIRE TO COOL FOR AT LEAST 30 MINUTES THEN PULL OUT BATTERY HOLDER THE COVER CAN SLIDE OFF AS ABOVE AND THE BATTERIES CAN BE REPLACED USE ONLY LIKE FOR LIKE ALKALINE AA BATTERIES...

Отзывы: