24VDC Loop Power Supply Operation Manual
2
BATTErIES
The 24VDCPS uses 2 AA batteries. Recommended batteries are Lithium (non-rechargeable), Alkaline, or NiMH (rechargeable). To avoid damage by over-dis-
charging, rechargeable batteries should be removed when the Low Battery LED
(
)
illuminates. Non-Rechargeable batteries may continue to be used until
the Red Fault LED
(
)
illuminates, at which time the output voltage will have fallen below 24 V. Lithium batteries are recommended for best performance in
cold weather operations.
Typical Battery Life (conditions: 12 mA loop current, 23° c)
Battery Chemistry
Type
Examples
Typical Battery Life (hours)
Low Battery Indication
(
)
Lithium
Non-Rechargeable
Energizer Ultimate
14.5
(10 hrs at -20°
c)
2 minutes remaining at 24 V output
5 minutes until output drops below 18 V
Alkaline
Non-Rechargeable
Rayovac Max Plus 815
Duracell MN1500
Energizer E91, EN91
6
30 minutes remaining at 24 V output
40 minutes until output drops below 18 V
niMH
Rechargeable
Energizer Recharge
9
Remove batteries immediately
niMH (Low Self Discharge)
Rechargeable
Sanyo Eneloop
7.5
Remove batteries immediately
!
CAUTION:
Do not use AA sized, 3.6 V Li-Ion batteries in the 24VDcPS. Doing so will damage the device.
Battery replacement
Remove the protective boot and slide the battery cover off. Replace the batteries, taking care to note the correct polarity.
For best results, always replace batteries in pairs. Do not mix fresh and old batteries or batteries of different types.
!
CAUTION:
To avoid damage by over-discharging, rechargeable batteries should be removed immediately when the Low Battery LED
(
)