Page 7 of 21
7
3.
INSTALLATION AND COMMISSIONING
3.1
Installation
Cabling
Use screened cable, with the cable screen earthed at the other end from the reader (the controller end).
Preferably the cable should not be more then 100 metres (330 ft) long for Wiegand interface, or 10
metres (33 ft) for the RS232 interface.
Positioning the reader and labels
The ELC1 reader is supplied with a spacer and a number of labels to suit different mounting locations.
Use the spacer where it is not possible to drill a hole for the reader.
Fixing to Glass:
The labels are fitted last. Using double sided sticky tape, locate and fix the spacer in
position with the cable running through one of the four
Cable Access Points
.
After electrical connections have been made to the reader attach it to the spacer using the screws
provided.
A
A
A
B
B
B
B
B
B
Spacer
correctly
polarised
Содержание CENSUS
Страница 2: ...Page 1 of 21 1 Complete ELC Reader Kit...
Страница 19: ...Page 18 of 21 18 Sales Literature...
Страница 20: ...Page 19 of 21 19...
Страница 21: ...Page 20 of 21 20...
Страница 22: ...Page 21 of 21 21...