Crunch Ground Ponder GPV2400.4 Скачать руководство пользователя страница 6

GROUND POUNDER

DRIVE

GROUND POUNDER

DRIVE

+  - gnd  -  +

HI INPUT

5V  0.2V         0dB  12dB      60Hz  1.2KHz    30Hz  250Hz

 LEVEL

       BASS EQ        HPF             LPF

FULL

 LPF HPF    MONO       STEREO

X-OVER            MODE

LINE OUT

  LINE INPUT

L

L

R

R

POWER INPUT

SPEAKER OUTPUT

BRIDGED

-  LEFT   +             -   LEFT  +

FUSE

GND     REM    +12V

+  - gnd  -  +

HI INPUT

5V  0.2V         0dB  12dB      60Hz  1.2KHz    30Hz  250Hz

 LEVEL

       BASS EQ        HPF             LPF

FULL

 LPF HPF    MONO       STEREO

X-OVER            MODE

LINE OUT

  LINE INPUT

L

L

R

R

POWER INPUT

SPEAKER OUTPUT

BRIDGED

-  LEFT   +             -   LEFT  +

FUSE

GND     REM    +12V

GPV800.2 / GPV1100.2 / GPV3500.2 2-CHANNEL AMPLIFIER APPLICATIONS 

4

Stereo high pass with mono low-pass in a 2 way active, or bi-amplified system

Crossover frequency control checklist:

In this application we will use a 2 channel amplifier for the high frequencies, and a second 

Highs amplifier:

one for the low frequencies, or mono sub bass. Please consult the speaker specifications 

- HI PASS: 100 Hz

to determine maximum amplifier power requirements.

- LOW PASS: N/A

Interconnect cable checklist:

Connect the inputs of the HIGHS amplifier to a Radio/CD with good quality RCA cables. 

Lows amplifier:

Connect the LINE OUT of the HIGHS amplifier to the inputs of the BASS amplifier with a 

- HI PASS (Subsonic filter): 10 Hz to 40 Hz

stereo RCA to RCA cable.

- LOW PASS: 80 Hz

Mono bass woofer wiring:

Please note that these frequency points are suggestions only. Refer to the loudspeaker 

Connect the mono speaker positive terminal to the RIGHT +, and its negative terminal to 

manufacturer specifications and the section

 “Setting up systems after installation for best 

LEFT -.

performance”

Switch setting checklist:

Level control checklist:

- Highs amplifier:

  

X-OVER

 switch in the 

HPF

 position.

- Refer to the section 

“Setting up systems after installation for best performance”

                               

MODE

 switch in the 

STEREO

 position.

Minimum final loudspeaker impedances:

- Lows amplifier:

  

X-OVER

 switch in the 

LPF

 position.

- 2-Ohms per channel stereo.

                              

MODE

 switch in the 

MONO

 position.

- 4-Ohms mono bridged.

FULL RANGE

STEREO LINE INPUT

STEREO

INTERCONNECT

RCA CABLE

MONO BASS

SPEAKER

REMOTE TURN-ON

REMOTE TURN-ON

CHASSIS GROUND

CHASSIS GROUND

TO B 12 volts VIA FUSE

TO B 12 volts VIA FUSE

FULL RANGE

SPEAKERS

Содержание Ground Ponder GPV2400.4

Страница 1: ...AMPLIFIERS DRIVE GPV800 2 GPV1100 2 GPV3500 2 GPV1200 4 GPV1800 4 GPV2400 4 GPV2100 1...

Страница 2: ...down the amp to help prevent serious damage GeneralInstallationProcedure 1 AmplifierFeatureDescriptions 2 GPV800 2 GPV1100 2 GPV3500 2 2 CHANNEL AMPLIFIER APPLICATIONS 3 4 Fullrangestereo Fullrangemon...

Страница 3: ...g hole and use a bolt spring washer and nut to securely fasten the ground lug Use petroleum jelly to coat the bolt lug connection to prevent oxidization with time TIP Use the same approach when instal...

Страница 4: ...you to select 2 3 or 4 channel operation TheX OVERslideswitchselectstheinternalcrossoverfunctions The input signal is routed directly to the LINE OUT RCA jacks regardless of the X OVER setting simplif...

Страница 5: ...oll off together to obtain a mono signal as this could very well damage the output stage of that source It is necessary to feed the SAME signal to both left and right inputs via a Y adapter RCA Minimu...

Страница 6: ...klist Connect the inputs of the HIGHS amplifier to a Radio CD with good quality RCA cables Lowsamplifier Connect the LINE OUT of the HIGHS amplifier to the inputs of the BASS amplifier with a HIPASS S...

Страница 7: ...rolloff or built into a head unit or equalizer Important Do not be tempted to connect the hot or positive outputs from any source Level control checklist together to obtain a mono signal as this coul...

Страница 8: ...have dual speaker terminals simplifyingthehookupofmultiplespeakers Minimumfinalloudspeakerimpedance 1 Ohm FULL RANGE STEREO LINE INPUT NOT USED Y ADAPTOR Note You can use the Radio CD designated mono...

Страница 9: ...7...

Страница 10: ...n this setting acts as a low frequency cut off for your system reproduction The point that you set it at cuts off any frequencies from reproduction beyond this point The 12 o clock position is a great...

Страница 11: ...sethemainfusetoblow 3 Ifanamplifierfuseblowscontinually withonly 12volt groundandremoteleadsconnected theamplifiermaybefaulty Systemdoesnotturnon 1 Checkallfuses 2 Checkallconnections 3 Measure the 12...

Страница 12: ...contain the name and address of the authorized reseller Any damage to the product as a result of misuse abuse accident incorrect wiring improper installation alteration of date code or bar code label...

Страница 13: ...es and activates the MX 2 As an option the module also offers a remote turn on wire Remote Output Driver circuit to turn on amplifier when module activates MX 3 Bass Controller Parametric Bass EQ Prov...

Страница 14: ...T LEVEL PHASE BOOST PARAMETRIC BASS EQ BANDWIDTH FREQUENCY 0 2V 180 10 dB 100Hz 9V 0 0dB 30Hz MAXX LINK MLX 100 SUBSONIC FILTER 24 dB OCT LOW PASS FILTER 24 dB OCT OUTPUT LEVEL MODE ON SLAVE OFF MASTE...

Страница 15: ...PART S611...

Отзывы: