2.3.3 SAS Hard Drives (Available only on S5 models)

a.  Insert the hard drive into the cubby. Face the power and data connection side outward. 

b.  Attach the included SATA data/power connector to the rear of the drive.

c.  Connect the 4-pin power cable on the SATA data/power connector to the power port on the front of 

the Forensic LabDock.

d.  Connect the eSATA data cable of the SATA data/power connector to the “SAS Pass Thru” port above 

the 4-pin legacy Molex power port on the front of the Forensic LabDock. 

e.  Flip the power switch to the 

1

 position to power the Forensic LabDock on.

2.3.4 USB Thumb Drives (Available only on U5 models)

a.  Plug the device into the “USB WriteBlocker” port on the front of the Forensic LabDock. 

b.  If the device has an On/Off switch, turn it on. 

c.  Flip the power switch to the 

1

 position to power the Forensic LabDock on.

If the computer fails to recognize the thumb drive, cycle the thumb drive’s power (but removing and 

reinserting it or switching it off and on again) and then press the 

Remount

 button.

2.3.5 USB Drive Enclosures (Available only on U5 models)

This feature is useful for previewing the contents of a USB drive enclosure to determine if it contains 
digital evidence that you need to acquire. If it does, you can then decide whether to acquire the evi-
dence through the USB connection or to open the drive enclosure and attach the bare hard drive to the 
Forensic LabDock with an IDE or SATA write-blocked connection. 

Supported USB drive enclosures have the following characteristics: 

•  Are seen as a single physical device by your computer’s OS
•  Are powered by an AC adapter or an extra USB bus power cable

Connect the drive enclosure to the Forensic LabDock’s “USB WriteBlocker” port with a USB cable and 
power the enclosure on. Then flip the power switch on the Forensic LabDock to the 

1

 position to power 

the Forensic LabDock on.

2.3.6 Other Types of Drives

Compatible SATA and PATA drive adapters are available that allow the Forensic LabDock to access to 
2.5” PATA/IDE, Hitachi 1.8-inch, Toshiba 1.8-inch, MacBook Air 2010, mSATA, PCIe PATA, PCIe SATA, or 
PCIe USB drives. 

a.  Connect the drive to the adapter.

b.  Attach the included 4-pin legacy Molex power cable to the adapter and the other end to the front of 

the Forensic LabDock.

c.  Connect the appropriate SATA or IDE cable to the drive adapter and the other end to the Forensic 

LabDock.

d.  Flip the power switch to the 

1

 position to power the Forensic LabDock on.

NOTE

Содержание Forensic Labdock S5

Страница 1: ...Write blocked access to USB thumb drives U5 model only Access SAS drives via a RedPort SAS write blocked PCIe host bus adapter S5 model only Convenient storage cubby keeps your drives out of the way during imaging A quiet fan keeps the cubby cool Recognizes and reports the presence of a hidden area HPA or DCO on the hard drive Included software utility can be used to configure the Forensic LabDock...

Страница 2: ...1 Package Contents 2 1 2 Identifying Parts 2 1 3 LED Behavior 3 1 4 Warnings and Notices 3 2 Installation Steps 4 2 1 Configure HPA DCO Mode 4 2 2 Install the Forensic LabDock Into Your Computer 4 2 3 Connecting Hard Drives to the Forensic LabDock 5 2 3 1 SATA Hard Drives 5 2 3 2 IDE PATA Hard Drives 5 2 3 3 SAS Hard Drives Available only on S5 models 6 2 3 4 USB Thumb Drives Available only on U5 ...

Страница 3: ...Care The main circuit board of the Forensic LabDock is sus ceptible to static electricity Proper grounding is strongly recommended to prevent electrical damage to the enclo sure or other connected devices including the computer host Avoid all dramatic movement tapping on the unit and vibration Avoid placing the hard drives close to magnetic devices high voltage devices or near a heat source This i...

Страница 4: ...abDock inside a computer b Connect a SATA power cable from the computer s power supply to the rear of the Forensic LabDock c Flip the power switch to the 1 position to power the Forensic LabDock on d Download and install the Forensic Software Utility a free software application designed for use with the Forensic LabDock www cru inc com support software downloads forensic software utility e Open th...

Страница 5: ...ORENSIC LABDOCK 2 3 1 SATA Hard Drives a Insert the hard drive into the cubby Face the power and data connection side outward b Attach the included SATA data power connector to the rear of the drive c Connect the 4 pin power cable on the SATA data power connector to the power port on the front of the Forensic LabDock d Connect the eSATA data cable of the SATA data power connector to the write bloc...

Страница 6: ...ature is useful for previewing the contents of a USB drive enclosure to determine if it contains digital evidence that you need to acquire If it does you can then decide whether to acquire the evi dence through the USB connection or to open the drive enclosure and attach the bare hard drive to the Forensic LabDock with an IDE or SATA write blocked connection Supported USB drive enclosures have the...

Страница 7: ... task bar to find the correct icon Windows will indicate when it is safe to turn the Forensic LabDock off Reconnect a new drive to the Forensic LabDock turn it on and your system will automatically detect the new drive If you do not have an HBA installed follow these steps a For the Windows 8 product family press WINKEY X then select Device Manager from the menu that pops up For Windows 7 Vista an...

Страница 8: ...ccessible by the BIOS or OS Data can be hidden behind an HPA or DCO CRU forensic devices can alert you if there is an HPA or DCO so that you are aware of it and can take the necessary steps to retrieve the hidden data 6 2 WHY IS IT NECESSARYTO UPDATETHE FIRMWARE OF MY CRU FORENSIC DEVICE Firmware relates to the programs and data that control electronic products Firmware is enhanced over time usual...

Страница 9: ...IDE PATA connector One 1 USB SAS combo connector only USB is active on the U5 model only SAS is ac tive on the S5 model Rear Data Connectors One 1 write blocked SATA connector One 1 write blocked USB connector U5 model only One 1 SAS connector S5 model only One 1 USB connector for firmware configuration HPA DCO Handling Four modes of operation selectable using the Forensic Software Utility applica...

Страница 10: ...or any costs of procurement of substitute products or services lost profits loss of information or data computer malfunction or any other special indirect consequential or incidental damages arising in any way out of the sale of use of or inability to use any CRU product or service even if CRU has been advised of the possibility of such damages In no case shall CRU s liability exceed the actual mo...

Отзывы: