Installation
Step 19
Installation
Step 20
Installation
Step 21
Installation
Step 22
Ø8
Drill the marked holes to a depth of 45mm.
Insert the wall plugs and loosely screw the
Hang ‘N’ Lock into position through the
Hang ‘N’ Lock cams.
With the Hang ‘N’ Lock bracket loosely
attached to the wall, adjust for height and
screwdriver and align the bottom of the
Hang ‘N’ Lock bracket with the reference
line. Once level fully tighten using a philips
screwdriver.
Using an 8mm drill, drill the marked holes through the
support braces.
Insert wall plugs and re-hang the vanity unit in
position aligning the holes in the support braces.
Using a philips screwdriver screw through the
braces to reinforce the vanity unit on the wall surface.
Hang the vanity unit onto the Hang ‘N’ Lock bracket, checking
the unit is level.
Using a pencil mark through the support braces and remove the
vanity unit.
IMPORTANT!
The support braces provide additional reinforcement to support
the weight of the vanity unit and basin. Reinforcement screws
must be secured through the support braces to provide
additional strength.
Support Brace
Ø8
G. Wall Plugs
(H007) x 2
F. Fixing Screws
(H006) x 2