Unpack and Install Your Amplifier

Please unpack and inspect your amplifier for any damage that may have occurred during transit. If damage 

is found, notify the transportation company immediately. Only you can initiate a claim for shipping damage. 

Crown will be happy to help as needed. Save the shipping carton as evidence of damage for the shipper’s 

inspection.
We also recommend that you save all packing materials so you will have them if you ever need to transport 

the unit. Never ship the unit without the factory pack.
YOU WILL NEED (not supplied):
• Input wiring cables
• Output wiring cables
• Ethernet cables
• Rack for mounting amplifier (or a stable surface for stacking)

WARNING: Before you start to set up your amplifier, make sure you read and 

observe the Important Safety Instructions found at the beginning of this manual.
CAUTION: Before you begin, make sure your amplifier is disconnected from the 

power source, with the power switch in the “off” position and all level controls 

turned completely down (counterclockwise).

Use a standard 19-inch (48.3 cm) equipment rack (EIA RS-310B). See below figure for amplifier dimensions.

NOTE: When transporting, amplifiers should be supported at both front and back.

MAGNETIC FIELD

CAUTION! Do not locate sensitive high-gain equipment such as preamplifiers or 

tape decks directly above or below the unit. Because this amplifier has a high 

power density, it has a strong magnetic field which can induce hum into unshielded 

devices that are located nearby. The field is strongest on the right side and right 

bottom of the amplifier (facing the amplifier).

If an equipment rack is used, we recommend locating sensitive 

equipment at least 20 cm (8 inches) away from the amplifier.
When using an equipment rack, mount units directly on top of each 

other. Close any open spaces in rack with blank panels. DO NOT block 

front or rear air vents. The side walls of the rack should be a minimum 

of two inches (5.1 cm) away from the amplifier sides, and the back 

of the rack should be a minimum of four inches (10.2 cm) from the 

amplifier back panel. 

Setup

Содержание XLi 1500

Страница 1: ... manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of this manual please visit the Crown website at www crownaudio com Later versions of this manual and additional information about this product may be available at the Crown website at www crownaudio com Trademark Notice Crown and Crown Audio are registered trad...

Страница 2: ......

Страница 3: ...TICE CONDITION OR THE LIKE IF NOT CORRECTLY PERFORMED OR ADHERED TO COULD RESULT IN DAMAGE OR DESTRUCTION TO PART OR ALL OF THE COMPONENT WATCH FOR THESE SYMBOLS The lightning bolt triangle is used to alert the user to the risk of electric shock The exclamation point triangle is used to alert the user to important operating or maintenance instruc tions This device is designed and evaluated under t...

Страница 4: ...Visual and Entertainment Lighting Control Apparatus for Professional Use Part 2 Immunity EN 61000 4 2 2001 Electrostatic Discharge Immunity Environment E2 Criteria B 4k V Contact 8k V Air Discharge EN 61000 4 3 2001 Radiated Radio Frequency Electromagnetic Immunity Environment E2 criteria A EN 61000 4 4 2001 Electrical Fast Transient Burst Immunity Criteria B EN 61000 4 5 2001 Surge Immunity Crite...

Страница 5: ...wer Switch Push on push off Clip LED Yellow LED one per channel flashes when signal is audibly distorting Fault LED Red LED one per channel indicates channel shutdown Grill Allows flow through ventilation from front to back Signal Presence LED Green LED one per channel flashes when input signal exceeds 40 dBu Gain Control Sets ouptut level of each channel ...

Страница 6: ... to back fo rced air ow f or Circuit Breaker Pro vides overload protec tion Output C onnec tors One Speakon and one Binding P ost per channel connec t to loudspeakers Mode S witch Stereo dual P arallel or Bridge Sensitivity Switch 1 4V or 0 775V input sensitivit y Input C onnec tors One balanced XLR and one unbalanced RCA per channel AC Power Connec to r Cordset rating 10A 250V Cable Coating Mater...

Страница 7: ...r source with the power switch in the off position and all level controls turned completely down counterclockwise Use a standard 19 inch 48 3 cm equipment rack EIA RS 310B See below figure for amplifier dimensions NOTE When transporting amplifiers should be supported at both front and back MAGNETIC FIELD CAUTION Do not locate sensitive high gain equipment such as preamplifiers or tape decks direct...

Страница 8: ...inding Post Connectors 1 See Figure 4 On the back panel set the Output Mode Switch to STEREO 2 Wire the speakers to the binding post connectors as shown INPUTS STEREO PARALLEL BRIDGE RESET UTPUTS 3500 XL SE SITI IT ODE 220V 50 60H z 700W Professional Audio Amplifier Manufacture Crown Audio Inc Made in China INPUTS STEREO PARALLEL BRIDGE RESET UTPUTS 3500 XL SE SITI IT ODE 220V 50 60H z 700W Profes...

Страница 9: ...ost Connectors Bridge mono mode doubles the output power of the amplifier 1 See Figure 5 On the back panel set the Output Mode Switch to BRIDGE 2 Wire the speaker to the binding post connectors as shown 3 Only the Channel 1 Gain Control works in Bridge mono mode Wiring INPUTS STEREO PARALLEL BRIDGE RESET UTPUTS 3500 XL SE SITI IT ODE 220V 50 60H z 700W Professional Audio Amplifier Manufacture Crow...

Страница 10: ...ing Post Connectors With this wiring a signal sent to one of the input connectors is paralleled to both channels so that it is reproduced by both speakers 1 See Figure 8 On the back panel set the Output Mode Switch to PARALLEL 2 Wire the speakers to the binding post connectors as shown INPUTS STEREO PARALLEL BRIDGE RESET UTPUTS 3500 XL SE SITI IT ODE 220V 50 60H z 700W Professional Audio Amplifier...

Страница 11: ...tors Input Connectors One balanced XLR and one unbalanced RCA per channel Output Connectors Speaker Connectors 4 POLE Speakon and one pair Binding Post per channel Front Panel Controls Power on off switch one gain control per channel Rear Panel Controls Output mode switch stereo dual parallel or bridge Input sensitivity switch 0 775V or 1 4V Power Indicator One blue LED Signal Indicator One green ...

Страница 12: ... defective product at our authorized service center or our factory All expenses in remedying the defect including surface shipping costs in the United States will be borne by us You must bear the expense of shipping the product between any foreign country and the port of entry in the United States including the return shipment and all taxes duties and other customs fees for such foreign shipments ...

Страница 13: ......

Страница 14: ......

Отзывы: