Electric Counter Convection Steamer
CAUTION
In order to avoid any back pressure in the steamer, do not connect solidly to any drain connection.
Drain Connections
(
figure 2
)
The drain connection (Figure 2) must be 1” IPS down, preferably with one elbow only, maximum length of 2 feet before
open air gap and piped to an open air gap type drain. Drain pipe should be copper. DO NOT use PVC pipe - PVC pipe
may lose its rigidity or glue may fail.
Figure 2
Installation