QUAD ELEMENT PIR & MONO/COLOUR CAMERA MOTION DETECTOR With PET IMMUNITY

 

 

 

SETTING UP THE DETECTOR 

 

PET IMMUNITY SETTING  

Switch 1

 of dipswitch DIP5, use for setting the PET 

Immune function - Up to 15Kg or 25Kg, depending on 
the pet size.  

Position Up - ON - Immune to pet weighting up to 15 kg 
Position Down - OFF - Immune to a pet weighting up to 
25 kg   
 

PIR PULSE COUNT ADJUSTMENT 

Switch 2 

of dipswitch DIP5, use for setting the PULSE 

count function in order to provide PIR sensitivity control 
according to the environment.  
Position Up – ON – High sensitivity  
For stable environments. 
Position Down – OFF – Low sensitivity  
For harsh environments.  

 

LED SETTING  

 
Switch 3 

of dipswitch DIP5, use for setting - LED 

Enable / Disable. 
Position Up - ON – LED ENABLE, The LED will 
activate when the detector is in alarm condition. 
Position Down – OFF - LED DISABLE, The LED is 
disabled. 

 
Note:

 The LED Switch does not affect the operation of 

the relay. 
When an intrusion is detected, the LED will activate 
and the alarm relay will switch into alarm condition for  
2 sec. 

 

 

 

Fig.5 

 

 

N.O RELAY - TIME DELAY SETTING  

 

Switches 4 & 5 

of

 

dipswitch DIP-5 use for setting the 

time delay of the N.O. Relay terminals 6 & 7. 
There are four options. 

 Switch      Switch 
     4                5                 N.O. RELAY TIME DELAY  

   ON            ON                      2 Sec. Contact closed 
   ON            OFF                  15 Sec. Contact closed 
   OFF          ON                    60 Sec. Contact closed 
   OFF          OFF                240 Sec. Contact closed 
 
The N.C. Relay (Terminals 5 &6) opens for 1.8 – 2 sec. 
when an alarm occurs. 

PIR SENSITIVITY ADJUSTMENT 

Use the Potentiometer marked “PIR” to adjust the 
detection sensitivity between 15% and 100% according 
to walk test in the protected area. 
(Factory setting to 57%). 
Rotate  the  potentiometer  clockwise  to  increase  range, 
counter-clockwise to decrease range. 
 

AUDIO SENSITIVITY ADJUSTMENT 

Use the potentiometer “AUDIO” to adjust the audio 
sensitivity. 
Rotate the potentiometer clockwise to increase 
sensitivity.  
Rotate the potentiometer counter-clockwise to 
decrease sensitivity. 

  

BRACKET INSTALLATION OPTIONS 

 

     

Ceiling bracket base         Wall bracket base 

 

               

 

 

 

Fig.6 

 

 

TECHNICAL SPECIFICATION 

 

Camera Type 

B&W:     CCIR or EIA 

     

 

COLOR: PAL or NTSC   

Picture Elements 

290K (PAL; CCIR) 250K 

 

 

(NTSC;EIA)

 

Resolution  

420 TV lines (PAL; NTSC)  

 

 

380 TV lines (CCIR; EIA) 

Sensitivity  

0.5Lux - F2.0 (NTSC; PAL)   

 

 

0.5Lux - F1.2 (EIA; CCIR) 

S/N Ratio   

Better then 48 dB 

Electronic Shutter  
Time 

 

1/60 – 1/100,000 sec  

 

 

(NTSC; EIA) 

 

 

1/50 – 1/100,000 sec  

 

 

(PAL; CCIR) 

 

Video Output 

1V p-p  75

 

Detection Method 

Quad (four) element PIR 

Power Input 

8.2  to 16 Vdc 

Current Draw 

Mono:    115 mA 

 

Colour:  150 mA 

Temperature 

 

Compensation 

YES 

Alarm Period 

2 +/- 1  sec 

Alarm Output 

N.C 28Vdc 0.1 A with  

 

10Ohm series protection 

 

resistors 

Tamper Switch 

N.C 28Vdc 0.1A with  

 

10 Ohm series protection 

 

resistor - open when cover 

 

is removed 

Warm Up Period  

1 min 

LED Indicator 

 Red LED is ON during  alarm 

   

 

Dimensions            

123mm x 61mm x 38mm 

Weight         

135

 

gr.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

CROW ELECTRONIC ENGINEERING LTD. ("Crow") - WARRANTY POLICY CERTIFICATE 

This Warranty Certificate is given in favor of the purchaser (hereunder the "

Purchaser

") purchasing the products directly from Crow or from its authorized distributor. 

Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and 
year whose numbers are printed on the printed circuit board inside these products (hereunder the "

Warranty Period

").

 

Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such procedures 
are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal use and service. 
Repaired products shall be warranted for the remainder of the original Warranty Period. 
All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the 
Purchaser.  
Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part thereof) by 
anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure caused by software or 
hardware which Crow did not provide; (e) use or storage other than in accordance with Crow’s specified operating and storage instructions. 
There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on the face 
hereof.  
This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection with the 
products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether oral, written, (non-
mandatory) statutory, contractual, in tort or otherwise. 
In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or any third 
party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that these products 
can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these 
products will in all cases provide adequate warning or protection.  
Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without providing 
an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result.  
Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning.  
If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow’s maximum liability shall not in any 
case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow.

 

 

P/N 7101574   REV. B  Y.S - A.Y. 

 

CROW ELECTRONIC ENGINEERING LTD.

 

 

 ISRAEL

Crow Electronic Engineering Ltd. 

 

12 Kineret St. Airport City 

 

P.O. Box 293 Ben Gurion Airport , 70100 

 

Tel: 972-3-9726000 

 

Fax: 972-3-9726001 

                     

E-mail: 

[email protected]

 

USA

:                 

2160 North Central Road, 

                     

Fort Lee, N.J. 07024 

                     

Tel: 1-800-GET CROW  

                     

or     (201) 944 0005 

                     

Fax: (201) 944 1199 

                     

E-mail: 

[email protected]

 

AUSTRALIA

:    

429 Nepean HWY Brighton East Vic 3187 

                      

Tel:  61-3-9596 7222 

                     

Fax: 61-3-9596 0888 

                     

E-mail: 

[email protected]

 

  

POLAND:     

VIDICON SP. ZO. O.

 

                     

15 Povazkowska St. 

 

01 – 797 Warsaw  Poland 

                      

Tel:   48 22 562 3000 

                      

Fax:  48 22 562 3030 

                      

E-mail: 

[email protected]

 

LATIN AMERICA: 

CROW LATIN AMERICA  

 

5753 NW 151

ST

.Street 

 

MIAMI LAKES, 

 

FL 33014 – USA 

 

Tel:  +1-305-823-8700 

 

Fax: +1-305-823-8711 

 

E-mail: 

[email protected]

 

ITALY

:        

      DEATRONIC 

 

 

VIA Giulianello 4/14  

 

 

00178 ROMA, ITALY 

          

Tel:  +39-0676-12912 

          

Fax: +39-0676-12601 

          

E-mail: 

[email protected]

 

These instructions supersede all previous issues in circulation prior to October

 

2005.

 

 

     7101574_B 

  

 

 

- 2 - 

 

 

 

 

 

   

 

 

 

N345 

 

Отзывы: