Crown PIP-BEQ Скачать руководство пользователя страница 13

P.I.P.–BEQ

Page 13

Next, insert the edge connector of
the 

P.I.P.–BEQ into the PIP2 input

adapter (see Figure 3.19) and in-

A

B

B

A

18 PIN (B)

20 PIN (A)

Q43528-1

FROM AMPLIFIER

P.I.P.

MODULE

BACK PANEL

OF PIP2

AMPLIFIER

PIP2 CONNECTOR

BOARD

Fig. 3.18  PIP2 Input Adapter

Connection

Fig. 3.19  Installation into a

PIP2 Amplifier

3.2 Installation Procedures

You may need a phillips screwdriver
to remove the existing 

P.I.P. module

or panel from your amplifier.

CAUTION:

 Before connecting this

or any 

P.I.P. to your amplifier, it is

important to turn its level controls
down, turn it off and remove the AC
power. Don’t touch the circuitry.
Even though the amplifier is off,
there could still be enough energy
remaining to cause electric shock.

1. Turn down the level controls (full

counterclockwise), turn off the
amplifier and unplug it from the
AC power source.

2. Remove the existing 

P.I.P. mod-

ule or panel (two screws). For
PIP2 amplifiers, this may involve
disconnecting the 

P.I.P. from a

PIP2 input adapter (see  Figures
3.18 and 3.19). If a 

PIP2 input

adapter is already present, do not
remove the ribbon cables from
the adapter. Otherwise you will
have to reconnect them in the
next step.

3.

Standard P.I.P. Amplifiers: Align
the edges of the 

P.I.P.–BEQ in the

P.I.P. card rails and firmly push

P.I.P.

MODULE

BACK PANEL

OF AMPLIFIER

the unit in until it is seated against
the mounting bracket (see Figure
3.17).

PIP2 Amplifiers: (Requires a PIP2
input adaptor. Crown part num-
ber Q43528-1.) Connect the 

PIP2

input adapter to the two input
cables of the amplifier (see Figure
3.18). Notice that the 

PIP2 input

adapter should be positioned
with the 

P.I.P. edge connector on

top and facing away from the am-
plifier. The 20 pin cable (A) is con-
nected first then the 18 pin cable
(B) is connected. Both ribbon
cables should extend below the
PIP2 input adapter.

Fig. 3.17  Installation into a

Standard P.I.P. Amplifier

Содержание PIP-BEQ

Страница 1: ...ne 219 294 8000 Fax 219 294 8329 P I P modules are produced by the Professional Audio Division of Crown International Inc Trademark Notice Crown and P I P are registered trademarks of Crown International Inc Other trademarks are the property of their respective owners BEQ Programmable Input Processor P I P OUT IN C H 2 IN OUT C H 1 ...

Страница 2: ...P I P BEQ Page 2 ...

Страница 3: ...om equalization network for the Bose loudspeak ers Separate response curves al low the models 8 25 32 802 and BEQ Programmable Input Processor P I P OUT IN C H 2 IN OUT C H 1 Fig 1 1 P I P BEQ with Barrier Block Connectors 502A to be operated as full range or bi amped systems The equal ization can be turned off if desired Balanced inputs and daisy chain outputs use removable barrier block shown in...

Страница 4: ...3 4 5 6 7 8 ON 9 10 1 2 3 4 5 6 7 8 ON 9 10 1 2 3 4 5 6 7 8 ON 9 10 1 2 3 4 5 6 7 8 ON 9 10 E F B C A 802 NORM D F E R240 R140 NORM I H A G 802 S200 S201 S100 S101 FUL SUB BY EQ BY EQ FUL SUB BY EQ BY EQ Fig 2 1 Facilities ...

Страница 5: ...sistor and 0 1 microfarad capacitor E Output Connector Balanced 3 pin barrier block or XLR connectors are used for daisy chain output to other equipment Mating solderless plugs are in cluded for barrier block connectors The plugs are labelled for correct wiring F Input Connector Balanced 3 pin barrier block or XLR connectors are used for input to each channel Mating solder less plugs are also prov...

Страница 6: ... Amplified Off Off Off Off Off ON ON Off ON ON 502B X X X X X X X X X X Switch Bank S100 Table 1 S100 and S101 Switch Positions vs Model X switch position is unimportant Switch Number Model 1 2 3 4 5 6 7 8 9 10 25 32 Full Range ON Off Off Off X Off Off Off ON Off 25 32 Bi Amplified ON Off ON Off X Off Off Off Off Off 8 Full Range ON Off Off Off X Off Off Off ON ON 8 Bi Amplified ON Off ON Off X Of...

Страница 7: ...ll Range FUL N 32 Bi Amplified FUL N 8 Full Range FUL N 8 Bi Amplified FUL N 402 Full Range FUL N 402 Bi Amplified FUL N 502A Full Range FUL N 502A Bi Amplified FUL N 802 Full Range FUL 802 802 Bi Amplified FUL 802 502B SUB X Table 2 802 Response Jumper Positions vs Model ...

Страница 8: ...pers and switches of the P I P BEQ must be set prior to installation See the previous section for a description of each jumper The graphs in Figures 3 1 through 3 11 show the typical frequency response for all valid switch com binations 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 ...

Страница 9: ... Equalization Response for Model 502A Full Range Fig 3 5 Equalization Response for Model 802 Full Range 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 Fig 3 4 Equalization Response for Model 502A Bi Amplified 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 ...

Страница 10: ...20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 Fig 3 7 Equalization Response for Model 402 Full Range 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 Fig 3 8 Equalization Response for Model 402 Bi Amplified 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 ...

Страница 11: ...Fig 3 9 Equalization Response for Model 8 Full Range 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 Fig 3 10 Equalization Response for Model 8 Bi Amplified 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 Fig 3 11 Equalization Response for Model 502B ...

Страница 12: ...order 12 dB octave or steeper filters see Figure 3 12 20 5 0 5 10 15 20 dB 10 100 1000 10000 Frequency Hz 100000 10 15 The way Bose uses the biamp desig nation does not limit the bandwidth passing to the upper high pass sec tion however it does lower the level of bass equalization employed see Figures3 13and3 14 Theadditional bass energy required is then derived from the 502B subwoofer see Fig ure...

Страница 13: ... source 2 Remove the existing P I P mod ule or panel two screws For PIP2 amplifiers this may involve disconnecting the P I P from a PIP2 input adapter see Figures 3 18 and 3 19 If a PIP2 input adapter is already present do not remove the ribbon cables from the adapter Otherwise you will have to reconnect them in the next step 3 Standard P I P Amplifiers Align the edges of the P I P BEQ in the P I ...

Страница 14: ...member Crown is not liable for any damage resulting from over Fig 3 20 Audio Wiring BALANCED SOURCE UNBALANCED SOURCE driving other components in your sound system Figure 3 20 shows how to wire a balanced and unbalanced source or daisy chain output to the barrier block connectors Important If the amplifier is used in either Bridged Mono or Parallel Mono mode you must turn the Ch 2 amplifier level ...

Страница 15: ...Bu Common Mode Rejection Better than 60 dB up to 1 kHz Crosstalk Less than 60 dB from 20 Hz to 20 kHz Connectors Solderless barrier block or XLR connectors depend ing on model for both input and daisy chain output Input Impedance Nominally 50 kohms balanced 25 kohms unbal anced Maximum Input Level 20 dB Output Impedance daisy chain output Nominally 75 ohms bal anced Maximum Output Level daisy chai...

Страница 16: ... Group Plant 2 SW 1718 W Mishawaka Rd Elkhart Indiana 46517 U S A Phone 800 342 6939 North America Puerto Rico and Virgin Islands or 219 294 8200 Fax 219 294 8301 Fax Back North America only 800 294 4094 or 219 293 9200 Fax Back International 219 294 8100 Internet http www crownintl com ...

Отзывы: