3.7 Connect to AC Mains

Connect the AC power cordset of your amplifier 
to the AC mains power source (power outlet). 
NOTE: The plug supplied with 120V versions of 
the MA5000VZ is a 120V, 30-ampere plug 
(Figure 3.9).

NOTE: The third prong of this connector 
(ground) is an important safety feature. 
Do not attempt to disable this ground 
connection by using an adapter or other 
methods.

Amplifiers don’t create energy. The AC mains 
voltage and current must be sufficient to deliver 
the power you expect. You must operate your 
amplifier from an AC mains power source with 
not more than 10% variation above or below the 
amplifier’s specified line voltage and within the 
specfied frequency requirements (indicated on 
the amplifier’s back panel label). If you are 
unsure of the output voltage of your AC mains, 
please consult your electrician.

3 Setup

 

3.8 Startup Procedure

Use the following procedure when first turning on your 
amplifier:

1.

Turn down the level of your audio source. 

2.

Turn down the level controls of the amplifier.

3.

Turn on the “Enable” switch. The Enable indicator 
should glow. 

4.

Turn up the level of your audio source to an opti-
mum level.

5.

Turn up the Level controls on the amplifier until 
the desired loudness or power level is achieved.

6.

Turn down the level of your audio source to its 
normal range.

If you ever need to make any wiring or instal-
lation changes, don’t forget to turn off the 
amplifier and disconnect the power cord.

For help with determining your system’s opti-
mum gain structure (signal levels) please 
refer to the Crown Amplifier Application 
Guide, available online at
www.crownaudio.com.

4 Operation

4.1 Precautions

Your Macro-Tech Series amplifier is protected 
from internal and external faults, but you should 
still take the following precautions for optimum 
performance and safety:

1.  Before use, your amplifier first must be con-

figured for proper operation, including input 
and output wiring hookup. Improper wiring 
can result in serious operating difficulties. 
For information on wiring and configura-
tion, please consult the Setup section of this 
manual or, for advanced setup techniques, 
consult Crown’s Amplifier Application 
Guide available online at www.crownau-
dio.com.

2.

Use care when making connections, select-
ing signal sources and controlling the out-
put level. The load you save may be your 
own!

3.

Do not short the ground lead of an output 
cable to the input signal ground. This may 
form a ground loop and cause oscillations.

4. Never connect the output to a power 

supply, battery or power main. Elec-
trical shock may result.

5.

Tampering with the circuitry, or making 
unauthorized circuit changes, may be haz-
ardous and invalidates all agency listings.

6.

Do not operate the amplifier with the Signal/
IOC LEDs constantly flashing. 

7.

Do not overdrive the mixer, which will cause 
a clipped signal to be sent to the amplifier. 
Such signals will be reproduced with 
extreme accuracy, and loudspeaker damage 
may result. 

8.

Never operate the amplifier with less than 
the rated load impedance. Due to the ampli-
fier’s output protection, such a configuration 
may result in premature clipping and 
speaker damage. 

Remember: Crown is not liable for damage that 
results from overdriving other system compo-
nents

Figure 3.9 120V, 30A Power Plug

 Supplied with 120V Versions of the 

MA5002VZ

Содержание Macro-Tech MA-5002VZ

Страница 1: ...tion or maintenance Note The information provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred To obtain the latest version of th...

Страница 2: ...14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objec...

Страница 3: ...cators 11 4 3 Back Panel Controls and Connectors 12 5 Advanced Features and Options 14 5 1 Protection Systems 14 5 1 1 Output Device Emulation Protection ODEP 14 5 1 2 IOC Input Output Comparator 14 5...

Страница 4: ...the best possible service from your amplifier 1 1 Features Grounded Bridge design delivers large voltage swings without stressing output transistors resulting in lower distortion and superior reliabil...

Страница 5: ...e the Important Safety Instruc tions found at the beginning of this manual 3 2 Install Your Amplifier CAUTION Before you begin make sure your amplifier is disconnected from the power source with power...

Страница 6: ...correct connector pin assignments for balanced wiring and Figure 3 4 for correct connector pin assignments for unbal anced wiring NOTE Custom wiring should only be performed by qualified personnel Bal...

Страница 7: ...wire for your output connectors see Figure 3 5 To prevent the possibility of short circuits wrap or otherwise insulate exposed loudspeaker cable connectors Using the guidelines below select the appro...

Страница 8: ...erating in Stereo mode 3 6 2 Bridge Mono Mode Typical input and output wiring is shown in Figure 3 7 INPUTS Connect input wiring to Channel 1 Refer to Section 3 4 for input connector pin assignments O...

Страница 9: ...of amp Refer to Section 3 5 for output connector pin assign ments Make sure the Mode switch is set to the Parallel position when operating in Parallel Mono mode NOTE Turn down full CCW the Channel 2...

Страница 10: ...ease refer to the Crown Amplifier Application Guide available online at www crownaudio com 4 Operation 4 1 Precautions Your Macro Tech Series amplifier is protected from internal and external faults b...

Страница 11: ...ence of input signals flashes brightly with a 0 1 second hold delay to indicate a difference distortion between the input and output signal of 0 05 or greater and flashes brightly with a 0 5 second ho...

Страница 12: ...on 5 2 4 for more info about LOI L Sensitivity Switch Three position switch Allows the selec tion of 26 dB 1 4V or 0 775V input sensitivity M Power Cord N Output Connectors High current output block a...

Страница 13: ...nnel P TRS Input Jack Standard PIP2 Module One per channel female TRS input jacks are provided Q XLR Inputs Standard PIP2 Module One per channel female XLR input con nectors are provided R Ground Lift...

Страница 14: ...ice the voltage seen by the output devices and twice the voltage generated by the power supplies The power supply bridge rectifier is not ground referenced and the transformer secondary is not center...

Страница 15: ...er of loudspeakers you can drive with the amplifier and this does not allow for a 4 ohm loudspeaker whose impedance drops below 2 ohms at 80 Hz This is why your amplifier has ILoad ILimit The ILoad fu...

Страница 16: ...ltage power supply fuse has blown Return amp to Crown or an authorized Crown Service Center for servicing CONDITION No sound POSSIBLE REASON The amplifier has just been turned on and is still in the 4...

Страница 17: ...ono mode 1 kHz with 0 1 THD 1 ohm 2 ohms 4 ohms 5 000 3 700 2 600 Performance Frequency Response at 1 watt 20Hz 20 kHz see Figure 7 3 0 1 dB Phase Response at 1 watt 10Hz 20 kHz see Figure 7 6 10 Sign...

Страница 18: ...or 26 dB 0 5 dB Required AC Mains 50 or 60 Hz 100 120 208 230 240 VAC 10 Power Draw at Idle 90 watts or less Construction Cooling Internal heat sinks with on demand proportional forced air cooling con...

Страница 19: ...0 1365 6060 4615 2865 6145 4485 2795 2505 1940 1270 5320 4070 2670 5285 4045 2670 2415 1895 1265 4845 3805 2545 4865 3820 2565 2545 1925 1270 5310 4060 2665 5275 4025 2670 2440 1510 870 4815 3100 1815...

Страница 20: ...20 K FREQUENCY Hz 100 1 K 10 K 20 K FREQUENCY Hz dB 44 50 56 62 68 74 80 7 Specifications Figure 7 3 Typical Frequency Response Figure 7 5 Typical Output Impedance Figure 7 6 Typical Phase Response Fi...

Страница 21: ...ct Crown Factory Service or Technical Sup port to obtain prepaid shipping labels prior to sending the unit Or if you prefer you may pre pay the cost of shipping and Crown will reim burse you Send copi...

Страница 22: ...enter or our factory All expenses in remedying the defect including surface shipping costs in the United States will be borne by us You must bear the expense of shipping the product between any for ei...

Страница 23: ...est insurance closing costs and other finance charges less a reasonable depreciation on the product from the date of original purchase War ranty work can only be performed at our autho rized service...

Страница 24: ...paratus for Professional Use Part 2 Immunity EN 61000 4 2 1995 Electrostatic Discharge Immunity Environment E2 Criteria B 4k V Contact 8k V Air Discharge EN 61000 4 3 1996 Radiated Radio Frequency Ele...