IQ-PIP-USP3/CN
page 10
Reference Manual
3 Installation
Before beginning, please carefully note:
CAUTION: STATIC ELECTRICITY MAY DAMAGE THE UNIT.
Use caution when handling
the unit. Carefully ground yourself BEFORE touching the unit. Avoided unnecessary touching
the components or solder pads on the circuit board. It is best to handle the unit by its front
panel only.
The USP3/CN cannot be used in conjunction with a CT210 due to the amount of heat gener-
ated in the PIP Module cavity and the lack of a fan in the amplifier. In addition, the USP3/CN
cannot be used in conjunction with a PIP2 adapter in a MA3600 due to the amount of power
required.
3.1 Prepare the IQ-PIP-USP3/CN
The IQ-PIP-USP3/CN comes ready to install in the amplifier. This unit does not require setting
the “IQ address” as the older current loop, Crown bus, units did. Each IQ-PIP-USP3/CN (as
well as all TCP/IQ components) come preprogrammed with a unique network (MAC) address.
The IQ address is then set (automatically or manually) via the IQ control software.
3.2 Prepare the Amplifier
Turn down the amplifier level controls (full counterclockwise) and turn off the
amplifier.
Disconnect the amplifier's power cord.
Remove the existing PIP module from the amplifier back panel (two screws). This may involve
disconnecting the PIP module from a PIP2 input adapter. If a PIP2 input adapter is present,
remove ribbon cables from the adapter.