background image

E-3) Impeller:

These pumps have their impellers threaded on with right hand threads.

The clearance between an open faced impeller and its wear surface in the volute is set at the factory at
approximately .015 inches. This clearance is re adjustable by relocating the shaft at the clamping
arrangement. In cases where much sand is being pumped, close clearances may bind the impeller and
volute and overload the engine. It may be necessary to provide extra clearance on these.

FIGURE 3

When reassembling a dismantled pump, clean all parts and especially areas where gaskets and o-rings are
located. Grease all gaskets and o-rings and areas where o-rings must slide when assembling.

10

Содержание G19

Страница 1: ...es may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification Models G6 G9 G19 CPB RATING 6M Model G6 8M Model G9 18M Model G19 420 Third Street...

Страница 2: ...RNED GOODS POLICY 17 WARRANTY START UP REPORT WARRANTY INFORMATION REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Crown is a registered...

Страница 3: ...e on any pump and on end suction and self priming pump the heat build may cause the generation of steam with resulting dangerous pressures It is recommended that a high case temperature switch or pres...

Страница 4: ...CHECK VALVE Suction Built in Material Valve Flap Neoprene Top Washer Zinc Plated Bottom Washer Stainless Steel BASE Steel with Carrying Handle ENGINE MODEL Briggs Stratton 80232 Type 1 Cylinder L Hea...

Страница 5: ...00 Series Stainless CHECK VALVE Suction Built in Material Valve Flap Neoprene Top Washer Zinc Plated Bottom Washer Stainless Steel BASE Steel with Carrying Handle ENGINE MODEL Wisconsin BKND Gasoline...

Страница 6: ...efficient performance following long inoperative periods in storage For best results pumps can be retained in storage as factory assembled in a dry atmosphere with constant temperatures for up to six...

Страница 7: ...ged deep enough to prevent air from being drawn into the suction line thus reducing the pump s capacity and pressure CAUTION THIS PUMP SHOULD NOT BE OPERATED WITHOUT A STRAINER ON THE END OF THE SUCTI...

Страница 8: ...ank may break it loose If not the pump must be dismantled SECTION E MAINTENANCE RECOMMENDATIONS E 1 Seal Lubrication A self feeding lubricator is provided to supply grease to the shaft seal of the pum...

Страница 9: ...nd polished to a 1 32 radius This radius and the shaft on which the rubber bellows grips must be polished with 180 to 240 grit emery cloth The seal will install relatively easy if the shaft is properl...

Страница 10: ...ustable by relocating the shaft at the clamping arrangement In cases where much sand is being pumped close clearances may bind the impeller and volute and overload the engine It may be necessary to pr...

Страница 11: ...gged foot valve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase i...

Страница 12: ...Pump serial number and date code 2 Pump model number 3 Pump part number 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions IMPORTANT When Orderin...

Страница 13: ...FIGURE 4 Pump Models G6 G9 13...

Страница 14: ...Clamp Impeller PSS 4476 15 4 Washer Lock Split 5 16 Zinc Plated 20 22 6 16 4 Screw Hex Hd 5 16 18 X 75 Zinc Plated 1 129 6 17 1 Pin Gauge Impeller T 20977 18 1 Seal Lip M 8759 19 1 Hub Impeller SS TS...

Страница 15: ...FIGURE 5 Pump Models G19 15...

Страница 16: ...4477 15 1 Pin Gauge Impeller T 20977 16 4 Screw Hex Hd 3 8 16 x 1 00 Zinc Plated 1 34 6 4 Washer Lock Split 3 8 Zinc Plated 20 14 6 17 1 Adapter Side Pump FP 4113 A 18 1 Seal Lip M 3649 19 1 Hub Impel...

Страница 17: ...f the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTO...

Страница 18: ...field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in fiel...

Страница 19: ...Person in Charge of Pump Phone Purchased from Crane Pumps Systems Representative Distributor Pumps Model Brand Part Number Trailer type Skid Mounted Contractor Trailer Highway Trailer Other Condition...

Страница 20: ...of Company Date I Certify this report to be accurate Name of Start Up person Employed by Date Date and Time of Start Up Present at Start Up Engineer Operator Contractor Other To be filled out by fact...

Страница 21: ...RIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warrant...

Страница 22: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE...

Отзывы: