![Crown CT61001HX Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/crown/ct61001hx/ct61001hx_original-instructions-manual_2690458026.webp)
26
English
•
Fig� 9�5, 10�5 - (the red indicator
23
is blinking, the
battery
5
is inserted in the charger
21
) - the charging
process of the battery
5
is terminated because of its
failure� Replace the faulty battery
5
, its further use is
prohibited�
In the process of charging the battery 5
and the charger 21 become hot, it is a
normal process.
Switching the power tool on / off
Switching on:
Press the plastic tip
14
to the surface and press the
power tool down until it stops, indicator
11
will light
up, indicating that the power tool is ready to shot (see
fig. 11.1). While holding the power tool in this position,
press the trigger
3
- a shot will occur (see fig. 11.2).
Switching off:
Release trigger
3
and raise the power tool�
Design features of the power tool
Temperature protection (see fig. 12.1-13.1)
The temperature protection system enables to auto-
matically deactivate the power tool in case of excess
load or when the temperature of the battery
5
is ex-
ceeding 80°C� The system guarantees protection of
the power tool from damage in case of noncompliance
with the operation conditions�
When this protection system is activated indicators
6
will blink as shown onto fig. 12.1-13.1 during 3 sec
-
onds�
Overheating protection (see fig. 12.1-13.1)
Overheating protection system of the engine automati-
cally switches off the power tool in case of overheat-
ing� In this situation, let the tool cool before turning the
power tool on again�
When this protection system is activated indicators
6
will blink as shown onto fig. 12.1-13.1 during 3 sec
-
onds�
Overload protection (see fig. 12.1-13.1)
Overload protection system of the engine automatically
switches off the power tool when it is operated in a man-
ner that causes it to draw an abnormally high current�
When this protection system is activated indicators
6
will blink as shown onto fig. 12.1-13.1 during 3 sec
-
onds�
Overdischarge protection
The battery
5
is protected by the safety system against
deep discharge� In case of complete discharge, the pow-
er tool is automatically switched off�
Attention: do not
try to switch on the power tool when the protection
system is activated the battery 5 can be damaged.
Indicators of the state of battery charge (see
fig. 12.2-13.2)
With the push of the button
7
the indicators
6
show the
state of charge of the battery
5
(see fig. 12.2-13.2).
Indicator (see fig. 11.1)
Indicator
11
signals the readiness of the power tool to
shot, at the same time highlighting the place where the
staple or nail will be driven�
Impact force adjustment
The required impact force can be set using regulator
2
�
The required impact force depends on the material
being processed, the working conditions and can be
established by practical testing�
Recommendations on the power tool op-
eration
General recommendations
•
Remove the battery
5
from the power tool and
install the fasteners
19
or
20
into the magazine
11
as
described above� Insert the battery
5
into the power
tool�
•
Make a shot at the work surface�
•
Evaluate the quality of driving fasteners:
•
if the upper part of the staple
19
or the head of the
nail
20
protrudes above the surface, increase the
impact force by turning the regulator
2
to the right�
Attention: when working for a long time with
insufficient impact force, increased wear of the
parts of the power tool occurs;
•
if the upper part of the staple
19
or the head of the
nail
20
is too deep in the surface, it is necessary to
reduce the impact force by turning the regulator
2
to
the left�
•
After finishing work, remove the battery
5
from the
power tool and remove the remaining fasteners
19
or
20
from the magazine
11
�
Power tool maintenance / preventive
measures
Before carrying out any works on the power tool
remove the battery 5.
Battery maintenance instruction
•
Charge timely before the battery
5
is completely
exhausted� Stop operation in low power and charge
it immediately�
•
Do not overcharge when the battery
5
is full, other-
wise it will shorten the life time�
•
Charge battery
5
in the room temperature of 10°C
to 40°C (50°F to 104°F)�
•
Charge battery
5
every 6 months without operation
for a long time�
•
Replace worn out batteries in time� Decline of
production or a significantly shorter runtime of the
power tool after charging indicates aging of the
battery
5
and the need for replacement� It should be
taken into account that the battery
5
may discharge
faster if the works take place in the temperature
below 0°С.
•
In case of long time storage without use, it is recom-
mended to store the battery
5
at room temperature, it
should be charged to 50%�
Содержание CT61001HX
Страница 1: ......
Страница 5: ...5...
Страница 6: ...6...
Страница 7: ...7...
Страница 8: ...8...
Страница 9: ...9...
Страница 10: ...10...
Страница 11: ...11...
Страница 12: ...12...
Страница 96: ...96 RCD RCD RCD GFCI ELCB...
Страница 97: ...97...
Страница 98: ...98 ANSI Z 87 1 CAN CSA Z94 3 12 4 011 89 CT XX XXXXXXX...
Страница 99: ...99 45 C min III 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5...
Страница 102: ...102 15 19 20 CROWN 1 www crown tools com Li lon Li lon...
Страница 104: ...104 RCD RCD RCD GFCI ELCB off...
Страница 105: ...105 off on...
Страница 106: ...106 ANSI Z 87 1 CAN CSA Z94 3 GOST 12 4 011 89 CT...
Страница 107: ...107 45 C min III 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Allen 19 20 21 22 23 24 25 5...
Страница 110: ...110 19 20 15 19 20 CROWN 1 www crown tools com Li lon Li lon...
Страница 112: ...112 RCD GFCI ELCB...
Страница 113: ...113...
Страница 114: ...114 ANSI Z87 1 CAN CSA Z94 3 12 4 011 89...
Страница 115: ...115 CT XX XXXXXXX 45 min III 1 2 3 4 5 6 7 8 9...
Страница 118: ...118 5 5 0 5 50 14 15 19 20 5 19 20 11 14 14 1 13 18 14 2 15 16 19 20 15 19 20 CROWN 1 www crown tools com Li lon Li lon...
Страница 120: ...120 RCD GFCI ELCB...
Страница 121: ...121...
Страница 122: ...122 ANSI Z87 1 CAN CSA Z94 3 12 4 011 89 CT XX XXXXXXX...
Страница 123: ...123 45 min III 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5...
Страница 126: ...126 1 www crown tools com Li lon Li lon i...
Страница 135: ...135 RCD GFCI ELCB...
Страница 136: ...136...
Страница 137: ...137 ANSI Z 87 1 CAN CSA Z94 3 12 4 011 89 CT XXXXXXX 45...
Страница 138: ...138 min III 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 1 1 18 2 14 2 14 3 6...
Страница 141: ...141 Li ion Li ion...
Страница 142: ...142...
Страница 143: ...143...
Страница 144: ...144...
Страница 145: ...145...
Страница 146: ...146...
Страница 147: ...147...
Страница 148: ...148...
Страница 149: ...149...
Страница 150: ...150...
Страница 151: ...151...
Страница 152: ...152...
Страница 153: ...153...
Страница 154: ...154...
Страница 155: ...155...
Страница 156: ...156...
Страница 157: ...157...
Страница 158: ...158...
Страница 159: ...159...
Страница 160: ......