Crown Bermuda Скачать руководство пользователя страница 1

Since 1949, homeowners have depended on us
for quality, value and service

AVAILABLE FROM

3633 I Street, P. O. Box 14818
Philadelphia, PA 19134
Phone: (215) 535-8900 Fax: (215) 535-9736
Visit us on the web: www.crownboiler.com

BSI-12/08-(10M)-R3

PN980531

* BSI345 and BSI379 not available for elevations above 2000 ft.
* BSI345 and BSI379 not available for use with LP gas

** Combustion efficiency
*** Volume to normal water line

1. Altitudes above 2,000 ft.– ratings should be reduced at a rate of 4% for each 1,000 feet

above sea level (U.S.A. only), in Canada, boilers are certified for altitudes up to 2,000 feet only.

2. Please specify fuel (natural gas or LPG) and ignition system type (standing pilot or electronic

ignition) when ordering.

3. Specifications and dimensions are subject to change without notice.

SPECIFICATIONS

Satisfied customers are our goal. So CROWN
boilers are factory assembled, pretested, and wired
for reliable and quick installation. Servicing is easy, with
features like convenient access doors and a jacket top
knock-out that permits removal around supply piping.

A wide range of products and capacities serves most
residential and commercial heating needs. Pricing is
competitive, backed by attractive warranties and
optional extended coverage.

Natural or LP Gas*

Basic

Heating

IBR Net Rating,

AFUE (%)

Dimensions (in.)

Water

Boiler

No. of

Input

Capacity

Steam

Standing

Int.

Vol.***

Model

Sections

(MBH)

(MBH)

(Sq. Ft.)

(MBH)

Pilot

Pilot

“A”

“B”

“C”

“D”

(Gal.)

BSI069

3

69

57

179

43

80.0

81.9

12-3/4

28

40-7/16

4

5.1

BSI103

4

103

85

267

64

80.0

82.0

16

28

40-7/16

5

6.5

BSI138

5

138

113

354

85

80.3

82.0

19-1/4

28

40-7/16

6

7.9

BSI172

6

172

142

446

107

80.6

82.1

22-1/2

28

40-7/16

6

9.3

BSI207

7

207

171

533

128

80.9

82.1

25-3/4

30

40-7/16

7

10.7

BSI241

8

241

199

621

149

80.0

82.2

29

30

40-7/16

7

12.1

BSI276

9

276

227

708

170

80.3

82.2

32-1/4

30

40-7/16

8

13.5

BSI310

10

310

253

792

190

81.5**

35-1/2

30

45-7/16

8

14.9

BSI345

11

345

282

883

212

81.6**

38-3/4

30

45-7/16

9

16.3

BSI379

12

379

309

967

232

81.6**

42

30

45-7/16

9

17.7

J-BOX

TRANSFORMER 

& RELAY

NORMAL

W

ATER

L

I

NE

SAFETY

V

AL

V

E

LEFT S

I

D

E

V

I

E

W

FRONT

V

I

E

W

R

I

GH

T S

I

D

E

V

I

E

W

G

AS

V

AL

V

E

V

ENT

D

AM

P

ER

2"

S

U

PP

LY

D

I

A

D

P

RESS

U

RE

G

A

U

G

E

P

RESS

.

L

I

M

I

T

LO

W

W

ATER

C

U

T-OFF

G

A

U

G

E

G

LASS

2"

RET

U

RN

FLOOR L

I

NE

D

RA

I

N

V

AL

V

E

(

OR ALTERNATE

2"

RET

U

RN

)

A

B

C

2

8 5/8

CROWN value built in...

Heat Exchanger constructed and tested in accordance

with ASME Section IV standard.

298-02-E

Отзывы: