![Crown Bermuda Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/crown/bermuda/bermuda_information-sheet_2690057001.webp)
Since 1949, homeowners have depended on us
for quality, value and service
AVAILABLE FROM
3633 I Street, P. O. Box 14818
Philadelphia, PA 19134
Phone: (215) 535-8900 Fax: (215) 535-9736
Visit us on the web: www.crownboiler.com
BSI-12/08-(10M)-R3
PN980531
* BSI345 and BSI379 not available for elevations above 2000 ft.
* BSI345 and BSI379 not available for use with LP gas
** Combustion efficiency
*** Volume to normal water line
1. Altitudes above 2,000 ft.– ratings should be reduced at a rate of 4% for each 1,000 feet
above sea level (U.S.A. only), in Canada, boilers are certified for altitudes up to 2,000 feet only.
2. Please specify fuel (natural gas or LPG) and ignition system type (standing pilot or electronic
ignition) when ordering.
3. Specifications and dimensions are subject to change without notice.
SPECIFICATIONS
Satisfied customers are our goal. So CROWN
boilers are factory assembled, pretested, and wired
for reliable and quick installation. Servicing is easy, with
features like convenient access doors and a jacket top
knock-out that permits removal around supply piping.
A wide range of products and capacities serves most
residential and commercial heating needs. Pricing is
competitive, backed by attractive warranties and
optional extended coverage.
Natural or LP Gas*
Basic
Heating
IBR Net Rating,
AFUE (%)
Dimensions (in.)
Water
Boiler
No. of
Input
Capacity
Steam
Standing
Int.
Vol.***
Model
Sections
(MBH)
(MBH)
(Sq. Ft.)
(MBH)
Pilot
Pilot
“A”
“B”
“C”
“D”
(Gal.)
BSI069
3
69
57
179
43
80.0
81.9
12-3/4
28
40-7/16
4
5.1
BSI103
4
103
85
267
64
80.0
82.0
16
28
40-7/16
5
6.5
BSI138
5
138
113
354
85
80.3
82.0
19-1/4
28
40-7/16
6
7.9
BSI172
6
172
142
446
107
80.6
82.1
22-1/2
28
40-7/16
6
9.3
BSI207
7
207
171
533
128
80.9
82.1
25-3/4
30
40-7/16
7
10.7
BSI241
8
241
199
621
149
80.0
82.2
29
30
40-7/16
7
12.1
BSI276
9
276
227
708
170
80.3
82.2
32-1/4
30
40-7/16
8
13.5
BSI310
10
310
253
792
190
81.5**
35-1/2
30
45-7/16
8
14.9
BSI345
11
345
282
883
212
81.6**
38-3/4
30
45-7/16
9
16.3
BSI379
12
379
309
967
232
81.6**
42
30
45-7/16
9
17.7
J-BOX
TRANSFORMER
& RELAY
NORMAL
W
ATER
L
I
NE
SAFETY
V
AL
V
E
LEFT S
I
D
E
V
I
E
W
FRONT
V
I
E
W
R
I
GH
T S
I
D
E
V
I
E
W
G
AS
V
AL
V
E
V
ENT
D
AM
P
ER
2"
S
U
PP
LY
D
I
A
“
D
”
P
RESS
U
RE
G
A
U
G
E
P
RESS
.
L
I
M
I
T
LO
W
W
ATER
C
U
T-OFF
G
A
U
G
E
G
LASS
2"
RET
U
RN
FLOOR L
I
NE
D
RA
I
N
V
AL
V
E
(
OR ALTERNATE
2"
RET
U
RN
)
“
A
”
“
B
”
“
C
”
2
8 5/8
CROWN value built in...
Heat Exchanger constructed and tested in accordance
with ASME Section IV standard.
298-02-E
Содержание Bermuda