DCi Series
Power Amplifiers
page 23
Operation Manual
AC Power Draw and Thermal Dissipation
AC Power Draw and Thermal Dissipation:
Pink noise 12dB crest factor, bandwidth limited 22Hz to 22kHz.
Typical line impedance used.
Data based on all channels driven.
DCI 4300 - Bridge
120 V~ 60 Hz
230 V~ 50 Hz
Condition
Load
Line
Current
(amps)
Power Dissipated as Heat
Line
Current
(amps)
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
1.0
119
405
102
0.6
121
414
104
1/8 Power
Pink Noise
Typical of program
material just at clip
4 ohms
1.0
221
755
190
1.0
139
475
120
8 ohms
1.4
298
1018
257
1.4
153
523
132
16 ohms
1.4
300
1023
258
1.4
145
495
125
140V
(32.67 ohms)
1.3
289
987
249
1.3
137
467
118
200V
(66.67 ohms)
1.3
291
994
250
1.3
141
480
121
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
4 ohms
3.5
199
681
172
1.8
190
649
164
8 ohms
5.3
225
768
194
2.8
222
759
191
16 ohms
5.1
201
685
173
2.7
190
647
163
140V
(32.67 ohms)
4.9
179
612
154
2.5
170
582
147
200V
(66.67 ohms)
5.0
185
633
160
2.5
174
594
150
DCI 4300 - Dual
120 V~ 60 Hz
230 V~ 50 Hz
Condition
Load
Line
Current
(amps)
Power Dissipated as Heat
Line
Current
(amps)
Power Dissipated as Heat
watts
BTU
kcal/hr
watts
BTU
kcal/hr
At Idle Awake
N/A
1.0
118
401
101
0.6
119
408
103
1/8 Power
Pink Noise
Typical of program
material just at clip
2 ohms
1.9
141
480
121
1.0
136
465
117
4 ohms
2.6
156
532
134
1.4
149
507
128
8 ohms
2.6
149
509
128
1.4
142
484
122
70V
(16.33 ohms)
2.5
143
489
123
1.3
139
475
120
100V
(33.33 ohms)
2.5
149
507
128
1.3
142
485
122
1/3 Power
Pink Noise
Typical of program
material at
extreme clip
2 ohms
3.4
194
661
167
1.8
184
629
159
4 ohms
5.5
219
749
189
2.9
211
719
181
8 ohms
5.0
191
653
165
2.6
181
618
156
70V
(16.33 ohms)
4.9
183
624
157
2.6
177
604
152
100V
(33.33 ohms)
5.0
197
673
170
2.6
191
652
164
Содержание 4300