Operation
Operating your SB-1 side burner is relatively simple. Once you have properly
installed the unit and performed a leak test, you may proceed.
START-UP
1. Remove the protective cover while lighting.
2. Push and turn the burner valve counter-clockwise to the low setting and
light the burner through the grate with a book match or lighter.
3. Adjust the flame setting as desired while cooking.
SHUT-DOWN
1. Turn the burner valve to the OFF Position and replace the protective cover.
2. Shut off the gas supply valve when you are finished cooking. Do not leave
any gas supply valve open while your MCB grill or side-burner is not in use
Keep the area around the side-burner and MCB grill free of combustible
materials such as grass, leaves, paper, gasoline and other flammable liquids or
materials.
Do not obstruct the flow of air around the burner, vent holes on the front of
the unit, or the openings in the corners of the recessed area and around the
burner.
IF YOU SMELL GAS: Shut off all burners and pilots on all appliances. Shut
off and disconnect all gas supply valves and hoses. Do not operate the
appliance(s) until the problem is repaired. If the problem persists, immediately
consult your gas supplier. Keep the area free of any and all sources of ignition.
Instructions to be used in the event the user smells gas should be posted in a
prominent location. This information can be obtained from your local gas
supplier.