UNPACKING
Immediately after unpacking, check for possible shipping damage. If the kettle is found to be
damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the electrical service agrees with the specifications on the rating
plate located on the right side of the tilt console. If the supply and equipment requirements do
not agree, contact your dealer or Crown Food Service Equipment Ltd.
Select a location with drainage directly below the tangent draw-off (if so equipped). Allow
sufficient rear clearance from wall for kettle cover to lift upright freely and completely without
obstructions.
INSTALLATION
1. The kettle must be installed in accordance with:
1. State and/or local codes.
2. In the USA, the National Electrical code, ANSI/NFPA-70 (latest edition). In Canada, the
Canadian Electrical Code, Part 1, CSA Standard C22.1 (latest edition).
2. Set the kettle in the installation location.
3. With the kettle in the upright position, place a carpenter’s level on top of the kettle and turn
the adjustable feet to level kettle side-to-side and front to back.
4. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
5. Remove kettle and drill holes in locations marked on the floor (see installation diagram).
Insert proper anchoring devices to accommodate 5/16" size lag bolts (not supplied).
6. Reposition kettle. Re-level kettle by making necessary adjustments on flanged feet.
7. Bolt down kettle and seal with Silastic or other equivalent sealing compound. Sealant must
be applied not only to bolt heads but also around flanges making contact with floor surface
to fulfill NSF requirements. Wipe off excess sealant immediately.
Part No. 10069R6
5
2018-06-25