24
FIGURE 17: INDIRECT WATER HEATER FIELD WIRING
Feeder Wiring for Boilers Equipped with Hydrolevel CG450 Low Water Cut-offs
1) Using Hydrolevel VXT-120 feeder - Do not alter factory boiler wiring. Connect VXT-120 to CG450 as follows:
•
Connect the
BLACK
lead on the feeder to terminal
A
on the CG450.
•
Connect the
WHITE
lead on the feeder to terminal
2
on the CG450.
2) Using McDonnell & Miller WF2-U-120 feeder - Do not alter factory boiler wiring. Connect WF2-U-120 to CG450A as
follows:
•
Connect terminal
1
on the feeder to terminal
A
on the CG450.
•
Connect terminal
2
on the feeder to terminal
2
on the CG450.
•
Connect terminal
3
on the feeder to terminal
1
on the CG450.
Feeder Wiring for Boilers Equipped with McDonnell & Miller Low Water Cut-offs
Figures 18a and 18b show feeder wiring for McDonnell & Miller #101A, McDonnell & Miller WF2-U-120 and Hydrolevel
VXT-120 feeders on boilers equipped with #67 low water cut-offs.