Crown Boiler 32-380ECS Скачать руководство пользователя страница 12

380

475

380

475

I

A

PART # (STANDARD) 

310000 310001 310002 3110053 3110063 310405 310406 311026 311020 311010 310400 311027 311028 311031 1 EA.

1 EA.

BOILER MODEL

32-380ECS

1

1

3

1

1

1

1

1

1

1

1

311035 311037

32-475ECS

1

1

4

1

1

1

1

1

1

1

1

311035 311037

SERIES 32 MASTER PARTS LIST FOR 32-380ECS & 32-475ECS

DESCRIPTION

SECTIONS

  B

AS

SI

D

PA

N

EL

 C

AR

TO

N

  JA

C

KE

SI

D

PA

N

EL

 C

AR

TO

N

ECS

 W

AT

ER

 T

RI

M

 C

AR

TO

N

   

   

   

  

(L

ES

TA

N

KL

ES

H

EA

TE

R

)

EC

ST

EA

M

 T

R

IM

 C

AR

TO

N

  B

O

IL

ER

 C

AR

TO

N

 (E

C

W

AT

ER

  B

O

IL

ER

 C

AR

TO

N

 (E

C

ST

EA

M

)

R

IG

H

EN

D

   

   

   

   

   

   

  

(A

LL

 B

O

IL

ER

S)

PART #

SE

C

TI

O

N

 J

O

IN

ER

 C

AR

TO

N

ECS

 W

AT

ER

 T

RI

M

 C

AR

TO

N

   

   

   

  

(W

IT

H

 T

AN

KL

ES

H

EA

TE

R

)

EC

BA

SE

 C

AR

TO

N

IN

TE

R

M

ED

IA

TE

 C

AR

TO

N

QUANTITY

LE

FT

 E

N

D

   

   

   

   

   

   

   

(A

LL

 B

O

IL

ER

S)

IN

TE

R

M

EDI

AT

   

   

   

   

   

(A

ll 

BO

IL

ER

S)

INTERMEDIATE CARTON - See Installation Manual

10

380

475

380 ECS BASE ASSEMBLY

3131053

1

475 ECS BASE ASSEMBLY

3131063

1

REAR TIE ROD CHANNEL BRACKET

310311

1

1

5/8 X 4 STUD

900309

1

1

5/8 USS WASHER

900312

2

2

5/8 NUT

900311

2

2

JACKET REAR PANEL SUPPORT BRACKET

310310

1

1

JACKET TOP SUPPORT BRACKET

310320

1

1

#10 X 1/2 HEX HD SHEET METAL SCREW

90-212

12

12

GASKET ROPE

900145

6 ft

7 ft

5/16-18 X 5 CARRIAGE BOLT

900315

2

2

5/16-18 X 3 CARRIAGE BOLT

900313

2

2

5/16-18 WING NUT

900104

2

2

5/16 USS FLAT WASHER

900102

4

4

JACKET KNOBS

90-210

2

2

8-32 X 1/4 SCREW

90-211

2

2

3/8-16 X 3/4 CAP SCREW

90-035

4

4

3/8 USS FLAT WASHER

90-036

4

4

3/8-16 HEX NUT

90-221

4

4

ECS BASE CARTON

PART #

DESCRIPTION

"

I

"

"A"

"B"

"C"

"D"

"E"

7" PUSHNIPPLE

310005

4

5

6

7

8

9

3" PUSHNIPPLE

310006

4

5

6

7

8

9

5/8 X 9 3/4 TIE ROD

900310

12

15

18

21

24

27

5/8 HEX NUT

900311

24

30

36

42

48

54

5/8 FLAT WASHER

900312

24

30

36

42

48

54

LOCTITE # 592, 50 ml TUBE

900350

2

2

3

3

LOCTITE # 592, 250 ml TUBE

900355

1

1

"SECTION SEAL", 1 QUART CAN

900360

2

2

2

2

2

2

WOOD WEDGE

970030

2

2

2

2

2

2

SECTION JOINER CARTON

PART #

DESCRIPTION

QUANTITY

Содержание 32-380ECS

Страница 1: ...ral Draft Steam or Water Boilers Installation SUPPLEMENT FOR 32 380ECS 32 475ECS EQUIPPED WITH 24 VOLT CONTROL SYSTEMS Warning Improper installation adjustment alteration service or maintenance can ca...

Страница 2: ......

Страница 3: ...R Net Rating MBH Steam 228 I B R Net Rating ft2 Steam 950 Combustion Effy 80 5 Steam Water Volume to Normal Water Line Gal 24 51 Water Boiler Volume Gal 34 13 Output BHP 9 1 Arrangement of Steam Rise...

Страница 4: ...ng Figures D and F in the Wiring section show typical damper orientation 4 Install vent connector pipe and vent fittings from vent damper outlet to chimney or gas vent Secure with sheet metal screws a...

Страница 5: ...e wiring in the junction box as shown in Figure A Route the damper harness to the damper as shown in Figure D using care to make sure that it does not come in contact with the draft hood or steam pipi...

Страница 6: ...BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE RD RD RD ALARM ALARM 2 NOTE 2 2 WHEN DAMPER IS NOT USED DAMPER HARNESS IS REPLACED WITH JUMPER PLUG PILOT VALVE MAIN VALVE TH TR ROBERTSHAW 7000DER...

Страница 7: ...into this ter minal must be in excess of approximately 1 0 uA 9 Once the ignition module detects the presence of a pilot flame voltage is applied across the main valve terminals MV and MV PV opening t...

Страница 8: ...OW LIMIT HONEYWELL L8124E TH TR ROBERTSHAW 7000DERHC GAS VALVE PILOT VALVE MAIN VALVE RD RD RD YE RD RD YE ALARM ALARM Figure C Water Boiler Wiring With Tankless Heater Figure D Steam Boiler Control I...

Страница 9: ...le to recognize that a pilot flame is present the DC current flowing into this ter minal must be in excess of approximately 1 0 uA 8 Once the ignition module detects the presence of a pilot flame volt...

Страница 10: ...Figure F Water Boiler Control Installation Less Tankless Heater Version Shown Figure E Blocked Vent Switch Installation 8...

Страница 11: ...allowable temperature is 250 F If the high limit opens the vent damper will close if the damper switch is in the automatic posi tion The circulator will continue to operate as long as there is a call...

Страница 12: ...1063 1 REAR TIE ROD CHANNEL BRACKET 310311 1 1 5 8 X 4 STUD 900309 1 1 5 8 USS WASHER 900312 2 2 5 8 NUT 900311 2 2 JACKET REAR PANEL SUPPORT BRACKET 310310 1 1 JACKET TOP SUPPORT BRACKET 310320 1 1 1...

Страница 13: ...X 7 8 HEX HD CAP SCREW 900450 12 10 X 1 2 SHEET METAL SCREW 90 212 5 NYLON CABLE CLAMP 960030 3 1 1 2 NPT BLK PLUG 95 143 2 1 NPT BLK PLUG 950100 2 3 4 NPT BLK PLUG 95 048 4 1 2 NPT BLK PLUG 95 052 7...

Страница 14: ...E 95 070 1 1 2 X 1 4 BRASS BUSHING 95 146 2 1 2 X 3 BR NIPPLES 95 116 2 1 2 BR UNION 95 150 2 1 2 X CL BRASS NIPPLES 95 147 2 BLANK COIL PLATE 270003 2 COIL GASKET 270001 2 3 8 USS FLAT WASHER 90 036...

Страница 15: ......

Страница 16: ...PN 980895 05 10 Tel 215 535 8900 Fax 215 535 9736 www crownboiler com Manufacturer of Hydronic Heating Products P O Box 14818 3633 I Street Philadelphia PA 19134...

Отзывы: