3) If the T4 is switched on within 8 hours of being 

switched off, the following screen will be displayed 

for 10 seconds allowing the T4 to retain TWA, STEL 

and peak readings, simply press the operator button 

to retain, or allow the count to expire.

4) The screen will cycle through displaying the 

serial number, firmware version, configured user 

name, sensor lower and upper alarm levels, next 

calibration and bump test due dates, the date and 

time and autozero screen. 

5) The screen will then revert to the normal operation 

home screen, as shown below.

7. IN THE EVENT OF AN ALARM

•  In the event of gas concentrations exceeding the 

alarm thresholds for any gas being monitored, the 

T4 will activate the alarm signals.

•  Alarm signals – The red and blue alarm LEDs will 

flash, the sounder will emit a tone, the internal 

vibrator alarm will activate. The operator screen will 

display the gas in alarm and alarm level.

• 

When the gas level returns to normal, press the 

operator button. This will reset your T4 unit to 

normal run mode. If gas levels are still in alarm, the 

button will have no effect.

•  The T4 will also indicate if the battery has less 

than 30 minutes of life remaining, the sounder will 

emit a double blip every 5 seconds and the display 

will flash the battery empty icon. When the alarm 

sounds the user should move to a safe area before 

the 30 minutes expires.

1. IMPORTANT NOTES

• 

 For the use of MGF supplied equipment only.

  Ensure users are fully trained in the operation of this 

equipment and a site specific safe system of works is in 

place and adhered to.

  It is essential that site specific risk assessments are 

undertaken.

  Do not try to modify or change the equipment in any 

way as this could void any warranty or cause damage to 

equipment or persons using it.

  If in doubt concerning the integrity of any part of the 

equipment DO NOT USE IT

2. CROWCON TETRA 4 GAS DETECTOR

• 

The Tetra 4 multi-gas monitor is a compact, robust and

    easy-to-use diffusion based detector. Single button

    operation, small size and clear top-mounted display

    make it a favourite in the market amongst those working 

    in demanding industrial environments; such as those

    in the water, telecoms, food, brewing or hydrocarbons

    sectors.

Specifications

 

mgf.co.uk

 

GASES AND RANGES

Gas 

Range 

Resolution 

Flammable (Methane)

0-100% LEL

1% LEL

Oxygen (O2)

0-30% vol.

 

0.1% vol.

Hydrogen suplhide (H2S)

0-100ppm

1ppm

Carbon 

monoxide (CO)

1-1000ppm

1ppm

• While these are the standard gases we use, we have 

the ability to provide detection for other gases, 

please speak to the MGF Safety Department for 

further details.

4. MGF EXAMINATION AND TESTING

 

• Upon return to MGF the equipment will be cleaned, 

inspected and function tested by a competent and 

trained MGF safety technician.

5. VISUAL INSPECTION / FUNCTIONAL TEST - PRIOR 

TO USE 

•  Before the start of each use ensure that the 

equipment is clean and free from debris and there 

are no obvious defects.

•  Ensure that the item has a green tag, stating when it 

was last inspected.

•  Each item comes with a unique ID number, please 

ensure this can be found.

6. USING THE CROWCON TETRA 4 GAS DETECTOR

•  Switching on your unit

1) Ensure the unit is in clean air.

2) Switch on – Hold down the operator button for 3 

audible blips followed by one longer tone.

Size

135 x 80 x 35mm (5.3 x 3.1 x 1.4ins)

Weight

282g (9.9oz)

Alarms

Audible: 95dB

Vibrating

Visible: Bright red & blue LED’s

Display

Front mounted 

Backlit

180° flip for easy viewing while working

Data Logging

130 hours of data at 10 second intervals

Event Logging

Approx. 3500 events

Battery

Rechargeable Li-ion battery

Up to 18 hours runtime

5.5 hour recharge

Operating 

Temperature 

-20°C to +55°C (-4°F to + 131°F)

Humidity

10-95% RH 

@

 40°C non-condensing

Ingress 

Protection

Independently tested to IP65 and IP67

Compliance

EMC Directive 2014/30/EU

CE, FCC and ICES-003

Figure 1

Figure 2

Figure 3