10 11 12
FIG. 3 - TL-360 BOTTOM VIEW
IMPORTANT:
1. Do not install the detector where it may
encounter water, steam or oil.
2. Do not aim the detector directly at
sources of rapid heating or cooling such
as: forced air ducts, heaters.
3. Be sure to locate the detector so that
valuables are well within its coverage
pattern.
4. Range may vary in accordance with
ambient temperature.
DETECTION PATTERN FOR TL - 360
Installation Height
Detection Diameter
(Effective Range)
2.4m
8 ft
11m
36 ft
3m
10ft
14m
45.9ft
3.6m
12ft
16m
52.5ft
Example:
(See Fig. 4). If install at a height
of 3 m (10 ft) the detector will cover a circle
of 20m (65.5 ft) at floor level, with an
effective detection range of 14m (45.9 ft) in
diameter.
Note:
The detection range is the circle
pattern at floor level. The effective range is
the range at which an intruder will trigger
an alarm.
WALK TEST
After the installation, perform a walk test to
check that the detector operates properly.
FIG. 4 - TL-360 DETECTION AREA
13 14 15
DIP-SWITCH SETTINGS
PULSE COUNT
- DIP-SWITCH, “PULSE” -
provides control for normal or high risk
operating environments.
Position “1”
(OFF) - this setting is for a
stable environment.
Position “Auto”
(ON) - the TL-360 will
automatically select the appropriate pulse
count level (2 or 3) according to the
strength of the incoming signals. This
setting is for operation within a harsh
environment.
LED ENABLE -
DIP-SWITCH, “LED” -
to enable or disable the LED.
Position “ON”
- LED enable.
Position “OFF”
- LED disable.
FIG. 5 - LENS PATTERN
TECHNICAL SPECIFICATIONS
Power Input
8.2 - 16 Vdc
Current Draw
Active / Standby: 9 mA
Detection Method
4 (Four) element PIR
Sensitivity
∆
2
°
C (
∆
3.6
°
F) at
0.6 m/sec (2 ft/sec)
Detection Speed
0.5 - 1.5 m/sec
(1.5 - 5 ft/sec)
Bi Directional
Temperature YES
Pulse Count
1,2-automatic switch from
2 to 3 depending on
Alarm Period
1.6 sec
Alarm Output
N.C 28VDC 0.1 A
with 10 Ohm series
protection
resistor
Tamper Switch
N.C 28VDC 0.1A with
10 Ohm series protection
resistor - open when
cover is removed
16 17 18
TECHNICAL SPECIFICATIONS (CONT.)
Warm Up Period
20 sec
LED Indicator
LED is blinking
during warm up period
and self testing, LED is
ON
during
alarm
Operating Temperature -20
°
C to+50
°
C
(-4
°
F to +122
°
F)
RFI Protection
≥
30V/m
10 - 1000MHz
EMI Protection
50,000V of
electrical
interference
from
lightning or power
through
Visible Light Protection stable against
halogen light 2.4m
(8 ft) or reflected
light
Dimensions
∅
110mm x 45mm
(
∅
4.33” x 1.77”)
Weight
123 gr. ( 4.37 oz )
CROW reserves the rights to change
specifications without prior notice
FULL 7 YEAR WARRANTY
CROW warrants this product to be free from defects in materials and
workmanship under normal use and service for a period of
seven
years
from the last day of the week and year whose numbers are printed on the
printed circuit board inside this product.
CROW’s obligation is limited to repairing or replacing this product, at its
option, free of charge for materials or labor, if it is proved to be defective
in materials or workmanship under normal use and service. CROW shall
have no obligation under this Limited Warranty or otherwise if the
product is altered or improperly repaired or serviced by anyone other
then CROW.
There are no warranties, expressed or implied, of merchantability or
fitness for a particular purpose or otherwise, which extend beyond the
description on the face hereof. In no case shall CROW be liable to
anyone for any consequential or incidental damages for breach of this or
any other warranty, expressed or implied, or upon any other basis of
liability whatsoever, even if the loss or damage is caused by CROW’s
own negligence or fault.
CROW does not represent that this product can not be compromised or
circumvented; that this product will prevent any person injury or property
loss or damage by burglary, robbery, fire or otherwise; or that this
product will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product
can only reduce the risk of burglary, robbery or other events occurring
without providing an alarm, but it is not insurance or a guarantee that
such will not occur or that there will be no personal injury or property loss
or damage as a result. Consequently, CROW shall have no liability for
any personal injury, property damage or any other loss based on claim
that this product failed to give any warning. However, if CROW is held
liable, whether directly or indirectly, for any loss or damage arising under
this limited warranty or otherwise, regardless of cause or origin,
CROW’s maximum liability shall not in any case exceed the purchase
price of this product, which shall be the complete and exclusive remedy
against CROW.
TALON
Series
“It’s All About Catch”
TL-360
0013692
USA
2160 North Central Road,
Fort Lee, N.J. 07024, USA
Tel: 1-800-GET CROW
or (201) 944 0005
Fax: (201) 944 1199
E-mail:
AUSTRALIA
429 Nepean HWY
Brighton East Vic 3187
Australia
Tel: 61-3-9596 7222
Fax: 61-3-9596 0888
E-mail:
These instructions supersede all previous issues
in circulation prior to Apr. 2000.
TL-360_UL
TERMINAL
BLOCK
LED
RELAY
PYROSENSOR
DIP SWITCH
TAMPER
ON
P L
AUT
O
1
ON
OFF
-
+
SENSITIVITY
ADJUSTMENT
0 (0)
12 (3.6)
10 (3)
8 (2.4)
32.8
(10)
21.6
(6.6)
10.8
(3.3)
0
(0)
10.8
(3.3)
21.6
(6.6)
32.8
(10)
EAGLE’S VIEW
SIDE VIEW
ft (m)
ft
(m)
65.6ft (20m)
Ceiling
3m (10ft)
14 m
(46ft)
0.8 m
(2.6ft)
Effective
Detection
Diameter
Floor
20 m
(65ft)