thecrowgroup.com
Page | 24
Areas
Click on an Area to display its available options.
Area Names
Parameter
Description
Default Configuration
Area Name
Enter name to identify the Area
Area #
Settings
Parameter
Description
Default Configuration
Report Arm at the end of Exit
Delay
If this option is on the panel will report the Arm/Stay Arm
signal to a monitoring station when the exit delay expires. If it
is off, the panel will report the arm signal immediately the
system has been armed
Not Selected
Use near and verified
alarm to report
To reduce the possibility of false alarms the panel can require
two alarms on different zones within a 45 minutes period
before a full alarm is sent. If this option is turned ON it applies
to all zones assigned to that area.
An alarm on a single zone will send a Near Alarm report to the
monitoring station. If no further alarms occur within 45
minutes, the near alarm timer is reset and a restore is sent for
the zone that activated. If the zone that activated is still in
alarm when the 45 minutes timer expires, a zone bypass for
that zone is sent and the zone will remain bypassed until the
area is disarmed. Any new alarms after the timer has expired
will send another Near Alarm report. If a second alarm on a
different zone occurs within 45 minutes of the Near alarm, an
Intrusion Verified alarm report will be sent. This format only
applies to Contact ID and Pager reporting.
Turning this option on will stop zone alarms from being
reported in Domestic & Voice formats as there are no
messages for near and confirmed alarms.
You must turn this option off if using Domestic or Voice
formats
Not Selected
Fail to arm if exit zone still
open
If this option is turned ON it doesn't give to arm or stay arm
the area if one of the low security zones or exit delay zones
still open after exit delay expired. This option not valid for
automatic arm by time zone.
Not Selected
Timers and Delays
Parameter
Description
Default Configuration
Area Exit Delay Time (sec)
Each Area can have its own exit delay time.
The delay can be programmed from 1-255 seconds in one
second increments. If the exit delay is set to '0' the panel
will be instantly armed.
60 seconds
Area exit stay delay time (sec)
Each Stay Mode Area can have their own exit delay time.
The delay can be programmed from 1-255 seconds in one
second increments. If the exit delay is set to '0' the panel
will be instantly armed.
60 seconds