7  Terminal Block Connections 

 

Terminal 1 - Marked “-” (GND) - 

Connect to the ground of the CP. 

Terminal 2 - Marked “+” (+12V) - 

Connect to a positive Voltage of 9.6 -16Vdc source 

(usually from the alarm CP) 

Terminals 3 & 4 - Marked “TAMP” -

 If a Tamper function is required connect these 

Terminals to a 24-hour normally closed protective zone in the CP. 

 

If the top cover of the detector is opened or the detector is detached from installation wall, an 

immediate alarm signal will be sent to the CP. 

Terminal 5 - Marked “EOL” - 

End of line – optional terminal for end of line resistors 

connections.  

Terminals 6, 7 & 8 - Marked “NC / C / NO” -

 These are the output relay contacts of the 

detector. Connect to a normally closed or normally opened zone in the control unit. When an 

intruder is detected, alarm relays (N.C. and N.O.)  will switch for 1.8 sec. 

 

7.1  Wire Size Requirements 

Use #22 AWG or larger wires. Use the following table to determine required wire gauge and 

length. 

Wire Length [m]    

205 

310 

510 

870 

Wire Length [ft.]    

800 

1200 

2000 

3400 

Wire Gauge [#]      

22 

20 

18 

16 

 

alarm shop

Содержание EDS-3000

Страница 1: ...S USER MANUAL USER MANUAL USER MANUAL USER MANUAL P N 7101691 Rev A EDS EDS EDS EDS 3000 3000 3000 3000 Outdoor Double Optics PIR Outdoor Double Optics PIR Outdoor Double Optics PIR Outdoor Double Opt...

Страница 2: ...2 alarm shop...

Страница 3: ...or Installation 9 7 Terminal Block Connections 11 7 1 Wire Size Requirements 11 8 Settings Adjustments 12 8 1 Detection beam direction 12 8 2 Detection range setting 12 8 3 Sensitivity Range and Pet i...

Страница 4: ...4 alarm shop...

Страница 5: ...ern will be set for every installation environment and protection site The EDS 3000 is designed to protect large areas and can easily be installed on walls in order to provide a solid protection of th...

Страница 6: ...S 3000 is combined of three detection elements Upper PIR element Lower PIR element Microwave element The upper PIR element has an adjustable detection height while the other two are fixed The followin...

Страница 7: ...two PIR detection beams A Lower PIR element which is fixed to 18m range and 60cm above ground level which helps avoiding pets detection over the entire area B Upper PIR element which has adaptive rang...

Страница 8: ...at more than 10 Deviation from horizontal line Facing metal doors Do not install near direct source of heat or air gust Clear all physical obstacles from the detection area e g Plants laundries etc C...

Страница 9: ...to a leveled straight and firm wall leaving 15cm 6 inches from the top and 15cm 6 inches from both sides for easy installation and maintenance 4 Rotating the detection beam may be required for guardi...

Страница 10: ...the detector 10 Attach the sealing U shaped Sponge Pad to the wire opening from the rear side after the wires connection and prior to final product affixing to the mounted bracket 11 Place the detect...

Страница 11: ...lation wall an immediate alarm signal will be sent to the CP Terminal 5 Marked EOL End of line optional terminal for end of line resistors connections Terminals 6 7 8 Marked NC C NO These are the outp...

Страница 12: ...ent housing to the desired direction 8 2 Detection range setting The EDS 3000 detection range may vary between 3m and 18m 10 ft to 59 ft while installed on 1 2m 4 ft height above the ground surface Ch...

Страница 13: ...tection range with immunity to pets weight up to 20kg 44 lbs Group B positions 6 A set sensitivity for 13m 42 ft detection range with immunity to pets weight up to 35kg 77 lbs Group C positions B F se...

Страница 14: ...example If detector is used for 13m 42 ft range in open space with sunlight and pets set switch to position 9 8 4 Indications setting The EDS 3000 has two types of indications 1 LED 2 Buzzer The insta...

Страница 15: ...d power limited source The detector shall be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply The detector is automatically operated once...

Страница 16: ...each test for the detector to stabilize Upon installation the unit should be thoroughly tested to verify proper operation Walk across the entire area where coverage is desired Should the coverage be...

Страница 17: ...ase Warm up Period 120sec 5sec LED Indicator LED is ON during ALARM RF Immunity 10 V m plus 80 AM from 80 MHz to 2GHz ElectroStatic Immunity 6kV contact 8kV air Transient Immunity 1kV Operation Temp 1...

Страница 18: ...18 alarm shop...

Страница 19: ...basis of liability whatsoever even if the loss or damage is caused by CROW s own negligence or fault CROW does not represent that this product can not be compromised or circumvented that this product...

Страница 20: ...8 E mail crow crowaust com au POLAND VIDICON SP ZO O 15 Povazkowska St 01 797 Warsaw Poland Tel 48 22 562 3000 Fax 48 22 562 3030 E mail vidicon vidicon pl LATIN AMERICA CROW LATIN AMERICA 5753 NW 151...

Отзывы: