Issue date:
15092019
SCREW
Turn on the main water supply, close all faucets except the new
Installation
Cleaning the cartridge
The concealed cartridge should give trouble
-
free service
however s
ervicing is a straightforward process.
To remove the cartridge
With
the
water supply
, carefully remove the cover cap
and using a hexagonal key loosen the screw but do not remove.
Using a 7/8” wrench, unscrew and remove the retaining nut.
Pull out the cartridge taking note of its orientation.
Wash the cartridge with clean running water, dry and lightly grease
the seal, (only use silicone grease).
Replace the cartridge followed by the nut, cover and handle.
Maintenance
Flow rate
NOZZLE
BODY
HANDLE
AERATOR
BODY
CARTRIDGE
RETAINING NUT
COVER
HANDLE
SCREW
HEXAGONAL KEY
INOX SCREW
PLATE
INOX PLUG
RECESSED BODY
FIXING PLATE
SPOUT
SPOUT
Warranty
-
This
Crosswater London
product is covered by a limited lifetime warranty. For full details, terms and conditions please visit our website.
For further information contact;
Crosswater London
, 393 Fortune Blvd., Milford, MA 01757
Toll free number: 844-XWATER-1 (844-992-8371) tel: 508-381-0433 fax: 508-381-6068
www.crosswater
london.
com
email: technical@crosswater
london.
com
Make a cavity in the wall in the required location to match with the bowl.
Note the required depth of the cavity from the rear to the front of finished
wall covering (min 2
-1/2"
to max 2
-7/8"
) .
Secure the fixing plate using the inox plugs provided noting the vertical
alignment of the central hole
Fix the recessed body onto the plate using the inox screws.
Hard
-
plumb the hot supply to the left inlet and cold to the right.
Flush through the pipework and check for leaks.
Finish
the
wall surface up to the exposed copper studs.
Pass the plate over the studs to cover hole.
Push the faucet body onto the studs and secure from the
underside with the set screws.
ATTENTION
:
Check all new connections for leaks.
Shut off the water heating system then, with the main water supply
turned off, open the lowest hot and cold faucets and allow to drain
until the pipes are empty.
Cleaning Instructions
Please see the website for care and cleaning instructions for specific finishes.
General cleaning tips:
Rinse away any traces of soap and gently dry with a clean, soft cloth after each use. Rinse completely with water and dry any overspray.
This will maintain the finish and avoid water spotting.
To remove mineral deposits, use a 50/50 solution of white vinegar and water. Do not allow the solution to soak on the product.
Simichrome Polish® contains a protective film to enhance maintenance and is helpful in preventing water spot buildup. Follow instructions to
ensure optimum results. Never use an abrasive material such as a brush or scouring pad to clean the surface. The use of abrasive cleaners,
cleansers or disinfectants will alter the surface finish and void the warranty.
Do not allow certain materials such as toothpaste, cologne, shaving cream, nail polish remover, vinegar, wine, drain and glass cleaners to
remain on the surface. Prolonged contact will alter surface finishes and void the warranty.
We DO NOT recommend using any household cleaners as many can cause damage to the finish.