Replacement Parts

2

This valve is designed to fit into a 
wall that is 2 3/4” to 3 5/16” from 
finished wall to the back of the valve.
If necessary extensions can be 
purchased separatley.

1

Turn off the water supplies. Install the 
valve so the finished wall will fit 
between the markers on the mud 
guard.

2

Using mounting holes secure the 
valve making sure the "UP" label 
outlet is on top. Facing the valve, 
the hot supply must be on the left 
and the cold on the right.

3

5

Warning

If soldering is required for 

any connection remove the cartridge 
and check valve assemblies before 
soldering.

6

Connect top outlet with proper 
fittings.Note: it is suggested that you 
anchor all water lines.

 Installation completed.

8

2 3/4

-3 5/16

2 3/4

-3 5/16

Best if  finished wall 
is flush to this surface

.

4

Connect valve body 3/4-NPT inlets 
to water supplies using the proper 
fittings.  Warning: This valve does 
not offer a back-to-back installation 
option.

Warning

7

1

.

Pressure test and flush the valve.

a. Prior to testing, remove cartridge and check valve assemblies.
b. Plug the outlet and check for leaks.
c. After testing, flush system.
d. Remove shower outlet plug. Re-install the cartridge and check valve assemblies.

2.Check for leaks.

Mounting hole

2

a

b

c

d

2

1

3

4

5

6

7

Order 

s

eparately if needed

NO. Description

Part NO.

1

2

3

Extension kit

9K3172

Cartridge

5K217404PL

Nut

5K217405NT

Check valve

5K013107PL

4

6

5

Temperature control rings 

Complete Mud Guard 

5K202716PL

5K202720PL

7

Cartridge

5K202711NT

This thermostatic valve has been preset at the factory 
to deliver water at a maximum of 120ºF.  If you would 
like to change this setting please refer to the 
temperature change instructions noted in the trim 
installation instructions for this valve.