WALL INSTALLATION
W
2
4
Fig. 1:
Make a slot into the wall to install the carter.
Slot size: 285 mm x 185 mm - 11.22 in x 7.28 in.
Slot depth: 100 mm - 3.93 in
Fig. 2:
Prepare 4 holes into the slot, distance from holes 160 mm - 6.29 in. Use for this template
supplied in the box.
Fig. 3
: Insert the rawplug inside the hole, tighten the nut until is completely locked.
Fig. 4
: Place the fi xing carter next to the wall and fasten it with the nuts.
ATTENTION
The wall must be fi nished covering operation included.
Fig. 5
: Cut the threaded bar in excess close to the nut.
Fig. 6
: Connect the flexy hoses (G1/2” F) for water supply. Connect the cable to the control unit.
After connecting the body to the system, turn on the stopcocks and check that the mixer tap unit
operates correctly. Keep the tap pressurised for a few minutes checking eventual leaks.
Fig. 7
: Insert the cable into the control unit and connect the colored cables, following the same
color. Close the connector lockoff. Prepare the cable for power supply.
Control unit dimensions: 100 x 270 x 70
Fig. 8
: Fix the shower head to the frame with 4 screws