Installation Instructions

6

-

1/2"

2

-5/8"

9

-3/

4

"

4

-7/8"

 dia. 

35"

3

9

-1/2"

Adjustable

wrench

Channel

locks

Plumbers’ putty

or caulking

Flat head

screwdriver

Cross head

screwdriver

Hexagonal

key

MPRO Floor-mount Thermostatic Tub Filler 

US-PRO418

Introduction

Installation notes

The faucets in this range are single flow (hot and cold water mix in the 
body) and should therefore be supplied with hot and cold water at 
balanced pressures. If the faucets are not supplied at balanced 
pressures then the mixer will not function correctly.
The minimum water pressure required for these faucets is 

20

 

psi. 

The maximum water pressure is 

60 

psi, (beyond which pressure

-

reducing valves must be 

installed

).

The faucets are fitted with quarter

-

turn ceramic disc cartridges which 

provide a good flow rate with very smooth movement.

 

IMPORTANT: 

Before beginning installation, check for any damage 

that may have occurred during transport. 

Note: Damage claims cannot be made during or after installation.

IMPORTANT: Please read these instructions carefully before you 

begin and retain for future reference. These instructions have 

been prepared for your guidance, you must exercise due care at 

all times. 

We do not accept responsibility for any problems that may occur 

through incorrect installation.

Dimensions

Tools required

The installation must comply with all plumbing codes including local 
codes and be installed by a licensed plumbing contractor. 

Install US-418ROUGH first using the instructions provided with it.

IMPORTANT

Before installing a new faucet it is essential that 

the 

supply pipes are thoroughly flushed 

in order to remove any 

remaining 

debris

, solder or other impurities. Failure to carry out this 

simple procedure can cause problems or damage to the working of 
the faucet.

Installing shut-off valves on incoming supply lines is recommended 
for ease of maintenance. 

T

urn off the main water supply before connecting to any existing 

pipework or doing any maintenance.

 

WARNING! Please check for any hidden pipes and cables, electric 

or otherwise

,

 before drilling holes in a wall

 or floor

.