Cleaning Instructions

Rinse away any traces of soap and gently dry with a clean, soft cloth after each use. Rinse completely with water and 
dry any overspray. This will maintain the finish and avoid water spotting. 
To remove mineral deposits, use a 50/50 solution of white vinegar and water. Do not allow the solution to soak on the 
product. Simichrome Polish® contains a protective film to enhance maintenance and is helpful in preventing water spot 
buildup. Follow instructions to ensure optimum results. 
Never use an abrasive material such as a brush or scouring pad to clean the surface. The use of abrasive cleaners, 
cleansers or disinfectants will alter the surface finish and void the warranty. 
Do not allow certain materials such as toothpaste, cologne, shaving cream, nail polish remover, vinegar, wine, drain and 
glass cleaners to remain on the surface. Prolonged contact will alter surface finishes and void the warranty.

We DO NOT recommend using any household cleaners as many can cause damage to the finish. 

Please see the website for care instructions for specific finishes. 

1

Remove the mud guard.

Set the handle in the desired off 
position and place handle assembly 
on the valve. Rotate clockwise 
securing the handle assembly and 
escutcheon to the wall and engaging 
the stem

 (see page 

first).

 

- If all functions smoothly go to step 

#15

- If the handle assembly will not 

engage the stem, go to step #4.

- If the handle assembly will not 

bottom out on the escutcheon go to 
step #10.

3

2

Carefully slide the escutcheon on 
valve. 

If the handle assembly will 
not engage the stem, 
remove the handle assembly. 

4

a

Add the threaded nipple and pressure balance 

stem extensions supplied with trim.
b) Set the handle in the desired off position and place
the handle assembly on the valve and rotate clockwise 
securing the assembly and escutcheon, engage to the
wall and the stem.
- If all functions smoothly go to step # 15
- If the handle assembly will not bottom out on the 

HVFXWFKHRQJRWRVWHS

Cut stem and nipple extensions the 

DPRXQWQRWHGLQVWHS1HYHU

cut the stem and nipple while still on 
the valve.  This may damage the 
valve.)

Remove the handle assembly, nipple
and stem extensions.

Re-install the nipple, stem extension 
and handle assembly.Go to step 
# 15.

Measure and note the 
distance ‘YY’ (the distance 
between the bottom of the 
handle assembly and the 
escutcheon).

8

9

6

7

5

11

Remove the handle and escutcheon 
assembly, the plate, stem and nipple.

If handle assembly will not bottom 
out the escutcheon to the wall, 
measure and note the distance 
‘XX’(the distance between the 
bottom of the handle assembly and 
the escutcheon)

Cut stem and nipple the amount 
noted in step # 10.  (Never cut the 
stem and nipple while still on the 
valve.  This may damage the valve.)

12

13

Re-install the trimmed stem and 
nipple on the valve.

Place escutcheon on valve.  Thread 
on handle assembly to secure 
escutcheon.

`

10

Installation Complete.

15

b

b

a

a

a

b

14

Note: For illustration purposes, lever handle version is shown. Please 

refer to page 5 for instructions on how remove the lever handle and to 

install the cross handle.

Warranty

:

 

This 

Crosswater London

 product is covered by a limited lifetime warranty. For full details, terms and conditions please visit our website.

 