11-02-T-PC
11-02-T-SN
11-02-T-PN
11-02-T-BZ
Installation Instructions
15121412-A
2
15121412-A
3
Replacement Parts
NO. Description
Part NO.
1
Washer, Key and Aerator
9Q1110PL
2
Handle Assembly(cold)
9Q1125
3
Handle Assembly(hot)
9Q1124
4
Set Screw & Allen Key
9Q1350NT
2
1
4
3
Rinse away any traces of soap and gently dry with a clean, soft cloth after each use. Rinse completely with water and
dry any overspray. This will maintain the finish and avoid water spotting.
To remove mineral deposits, use a 50/50 solution of white vinegar and water. Do not allow the solution to soak on the
product.
Simichrome Polish® contains a protective film to enhance maintenance and is helpful in preventing water spot buildup.
Follow instructions to ensure optimum results.
Never use an abrasive material such as a brush or scouring pad to clean the surface. The use of abrasive cleaners,
cleansers or disinfectants will alter the surface finish and void the warranty.
Do not allow certain materials such as toothpaste, cologne, shaving cream, nail polish remover, vinegar, wine, drain
and glass cleaners to remain on the surface. Prolonged contact will alter surface finishes and void the warranty.
We DO NOT recommend using any household cleaners as many can cause damage to the finish.
Please see the website for care instructions for specific finishes.
Cleaning Instructions
1
2
3
Remove the mud guards from the
spout nipple assembly, the hot and
cold valves.
4
Place the spout washer under the
spout and install spout on spout
nipple assembly. Be sure the spout is
firmly resting on the deck and secure
the spout. Secure the spout with the
setscrew.
Place the “O” ring over the cold valve.
Align the handle and place the handle
and escutcheon assembly into the
valve. Secure the assembly by turning
the escutcheon clockwise. Repeat for
hot valve.
Turn water supply on.
5
Remove the aerator with the supplied
key. Turn the faucet handles on full
for one minute to flush debris.
6
Re-install the aerator with key.
7
Installation complete.
11-02
-T