Cross Technologies 4116-T24 Скачать руководство пользователя страница 3

MODEL 4116-T24 Translator, UHF to UHF, Weather Resistant*

1.0  General

1.1  Equipment Description

The 4116-T24 Translator converts a 20 MHz bandwidth signal from the UHF input band (0.2 to 0.4 GHz) to a 
20 MHz bandwidth signal on the UHF output band (0.2 to 0.4 GHz), in 0.1 MHz steps. Front panel LEDs 
provide indication of DC Power, and PLL Alarm. The UHF to UHF gain is +20 dB, maximum. Connectors are 
Type N female for the UHF out, UHF in and UHF in Monitor and SMA female for the external 10 MHz 
reference input. Gain, band select, muteand internal 10 MHz frequency are controlled by the M&C (Ethernet 
and/or Status/Control). In AUTO, the 10 MHz reference stays in external if the external level is in the +2 to +8 
dBm range.  The 4116 is powered by a 100-240 ± 10% VAC power supply, and mounted in a 8”W X 6”H X 
16”D Weather Resistant* enclosure.

NOTE: *Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure/antenna hut OR 

mounted outdoors on an antenna assembly at their specified temperature ranges.  They are designed to be located “out in the elements” 

(water, sleet, snow, etc.) but they are not designed to be “submerged under” water.  If an extended temperature range is required, there 

is an Extended Temperature option (Option W21; -30˚C to +60˚C) available at an additional cost.  Contact Cross for quote. 

RF OUT

J5

10M IN

ETHERNET

RF IN

J1

J2

POWER

ALARM

J3

J4

10M OUT

FUSE

J8

AC IN

J7

F1

C

ROSS

 T

ECHNOLOGIES INC.

RF IN MON

MODEL 4116 TRANSLATOR

J6

.

STATUS / 

CONTROL 

..

....

.....

....

...

 Model 4116-T24    Multi-Band Block Translator Front Panel

4116-T24 
Translator 
Block Diagram

0.2 - 0.4 GHz 

UHF OUT

EXT
10 M

10 M
TO
PLLS

V
A
R

A
T
T

S
P

L

I

T
T
E

R

+10
UHF 
MON

1.75 GHz BP

1.95-2.15
GHz

0.5 GHz LP

0.2 - 0.4 

GHz 

UHF IN

1.95-
2.15
GHz

PLL, ATT, CONTROL

M&C

CONTROLLER

FIGURE 1     Model 4116-T24 Multi-Band Block Translator Block Diagram

4116-T24 Manual, Rev. G

 

 

     Page 3

    

                     03/27/13  

Содержание 4116-T24

Страница 1: ...without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipment s...

Страница 2: ...iod of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire...

Страница 3: ...E Weather Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges...

Страница 4: ...ver UHF band 0 5 dB 20 MHz BW Frequency Response Non inverting Frequency Sense 45 dB minimum at 20 dB gain Input to Output isolation 0 05 ppm max over temp internal reference external reference input...

Страница 5: ...losure Size Status Control Connector MS3112E14 18S Mating Cable Connector MS3116F14 18P Ethernet Conector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 AC Input Connector Clipper S...

Страница 6: ...front and rear panel See Figure 2 2 for mounting dimensions 2 0 1 Connection to AC Input Power The 4116 T24 utilizes a pre assembled AC power input cable as described below 4115 3 31 Power Input Conne...

Страница 7: ...rt to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T24 2 1 2 Ethernet Configuration Each 4116 T24 must be configured with an appropriate IP address Netmask and Gatew...

Страница 8: ...ager click on Network to display the Network Settings screen Enter the IP address Subnet mask and Gateway address with delimiter dots example 192 168 192 47 Click apply settings in the left frame to a...

Страница 9: ...9999 The following instructions explain how to establish such a Telnet connection using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File...

Страница 10: ...SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of...

Страница 11: ...Figure 2 F Device Server Configuration Menu 4116 T24 Manual Rev G Page 11 03 27 13...

Страница 12: ...low Up ALARM LED Red LED indicates upconverter alarm RF OUT 60 to 0 dBm 0 2 0 4 GHz UHF Output ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector RF INPUT Type N 50 0 2 0 4 GHz UHF Input...

Страница 13: ...ctor RJF6G Table 2 5 1 Monitor and Control Connector Monito Monitor and Control Connector Pinout Mating Mating connector part number MS3112E14 18S Pin Signal Description A Chassis Ground N Summary Ala...

Страница 14: ...ESS a external 10 MHz 2 to 8 dBm signal is connected to J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 via Ethernet or serial command 8 Check that a 10 MHz signal is present at th...

Страница 15: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T24 Manual Rev G...

Отзывы: